Why a VELUX window needs a separate flashing at all
A VELUX roof window arrives as two boxes: the window itself, and a flashing kit chosen for the roof covering around it. The window is the same whatever your roof is made of; the flashing is what changes, and picking the right VELUX flashing type is the difference between a skylight that sheds water for decades and one that sits awkwardly in the roof.
The flashing is a set of shaped aluminium parts, sometimes with a pliable apron or loose soakers, that wraps the outside of the frame and laps under and over the surrounding tiles or slates. Rain running down the slope hits the top of the window, is turned sideways by the head flashing, runs down the side channels and is released back onto the covering below the window by the apron. None of that depends on sealant. It works because each piece overlaps the next in the direction water flows, the same way the tiles themselves work.
That is why the kit has to match the covering. A flat Welsh slate is a few millimetres thick and lies almost flush with its neighbours. A clay pantile rolls up and down by several centimetres. A concrete interlocking tile has a deep profile with a channel on one edge. A flashing designed for one of these will not seal against the others, however carefully it is fitted.
VELUX identifies its flashings with a three-letter type code followed by a size code and a four-digit installation code, for example EDW CK02 0000. The size part simply matches the window (the guide to VELUX window sizes and codes explains how to read it). This page is about the letters and the last four digits: what each type is for, and how they map onto the roofs you find around Cambridge.
Reading the letters on a VELUX flashing code
The three letters tell you the job the flashing was designed for; the four digits after the size tell you how deep the window sits in the roof. Once you know those two things, the rest of the product name falls into place.
On the current range the first letter is usually E, which marks a flashing for the modern generation of windows. The second letter indicates whether it is a single window flashing (D) or a combination flashing for two or more windows grouped together (K). The third letter describes the roof covering: W and Z for profiled coverings such as tiles, L for slate and other thin, flat materials, and S for plain tiles laid with soakers.
The installation code at the end is the part people most often overlook. 0000 is a standard installation, where the window sits at the depth VELUX treats as normal. A code starting with 2, as in EDW 2000 or EDL 2000, is a recessed installation, where the window is set lower into the roof so the frame sits closer to the line of the tiles or slates. The two are not interchangeable: the frame is fixed at a different depth, and the flashing parts are shaped to suit.
| Code | Designed for | Typical Cambridge roof |
|---|---|---|
| EDW | Profiled tiles | Concrete interlocking tiles, pantiles |
| EDZ | Profiled tiles, simpler kit | Moderate-profile tiles |
| EDL | Slate, thin flat materials | Welsh slate terraces |
| EDS | Plain tiles with soakers | 1930s semis, village houses |
| EKW / EKL | Combinations | Twin or stacked windows |
Treat the table as orientation, not as a specification. VELUX publishes the exact profile heights and material thicknesses each kit is tested for, and those limits are what the choice rests on. At survey we measure the covering on your roof and check it against the current product data before anything is ordered.

EDW: the tile flashing for profiled coverings
EDW is the flashing VELUX designs for profiled roof coverings, meaning tiles with a noticeable wave or rib. It is the kit you are most likely to see on a concrete-tiled roof anywhere from Cherry Hinton to Cambourne.
Its defining part is the bottom apron. Below the window the covering does not lie flat: it rises and falls with the tile profile, and a rigid strip would leave gaps where wind-driven rain could blow back up. The EDW apron is pliable, so it can be dressed down into the troughs and over the rolls of the tile beneath, closing those gaps while still letting water run off freely.
Along the sides, the EDW kit uses channels that sit beneath the tiles, which are cut and laid back over them. At the head, a top flashing runs under the course above the window and carries water around the frame. Because the kit is designed around a profile, it copes with the deep interlocking tiles common on 1960s and 1970s estates, the newer concrete tiles on houses in Great Kneighton and Orchard Park, and the clay pantiles found on older cottages and outbuildings in the Fen-edge villages.
The practical point for a homeowner is that EDW is also forgiving of slightly irregular old roofs. A pantile roof on a cottage in Willingham or Cottenham has rarely stayed perfectly true after a century or more, and a pliable apron can follow a tile that has settled at a slight angle in a way a stiff one cannot.
EDZ: the simpler profiled flashing
EDZ is also a flashing for profiled coverings, but it is a simpler kit, and it turns up on many older installations as well as on some new ones. The choice between EDZ and EDW is about the profile you are working with and how the apron needs to behave.
Where EDW is built around a malleable apron that can be shaped to deep, uneven tiles, EDZ uses a more straightforward construction. VELUX sets the profile limits for each, and those limits have changed across product generations, so the only safe way to choose between them is to measure the tile and check the current data. On a roof with a gentle, regular profile, EDZ can be an entirely sound choice. On a deep pantile or a heavily ribbed concrete tile, the EDW apron gives a closer fit.
EDZ matters most when you are replacing an older window. Many roofs around Cambridge carry VELUX windows fitted in the 2000s with an EDZ kit, and when the time comes to renew one, the question is whether to go like-for-like or to step up. We decide that on the roof, not from a catalogue: a flashing that has done its job for twenty years on a modest tile profile is useful evidence, while a roof that has been re-covered in a deeper tile since the window went in is a reason to change type.
EDL: slate and thin flat materials
EDL is the flashing for slate and similar thin, flat coverings, and it is the one that suits the Victorian and Edwardian terraces of Romsey, Petersfield and the streets off Mill Road, where Welsh slate is the norm.
Slate lies close to the roof plane, so there is no profile for an apron to follow. Instead, the EDL kit is lower and slimmer. The side pieces sit beneath the slates, which are cut neatly to line up with the frame, and the bottom flashing lies flat on the slate below rather than being dressed into a wave. The result is a much tidier outline from the street: the window reads as a flat rectangle set into a flat roof.
VELUX also rates EDL for other thin, flat coverings such as some fibre cement slates and certain flat interlocking tiles, within a stated maximum thickness. Many newer homes use artificial slates, and they often suit EDL well, but some so-called slate-effect concrete tiles are much thicker than real slate and belong with a tile flashing instead. It is one of the more common places where a kit ordered from a photo turns out to be wrong once someone is on the roof.
On a slate terrace the flashing choice also has a light consequence. A rear slope in Romsey or De Freville often faces east or west, and the slim EDL outline lets the window sit where the room needs the light rather than where a bulky kit would look least out of place. We plan the position first, using the orientation work described in how we plan the light, and choose the flashing to suit.
EDS and plain tiles: why soakers still matter
Plain clay tiles are small, flat and double-lapped, so every course overlaps two below it. A flashing for them needs individual metal soakers woven in with the tiles along each side of the window, and EDS is the kit VELUX supplies for this.
Plain tiles are everywhere in and around Cambridge: on 1930s semis along the arterial roads, on Arts and Crafts houses in Newnham and on countless village houses in Great Shelford, Histon and beyond. Their thickness and double lap mean a slate kit would leave a step at the sides, and a profiled kit has nothing to grip. The EDS approach mirrors how a roofer would traditionally detail a chimney in a plain tile roof: a soaker goes in with each tile, turned up against the frame, and a cover flashing lies over the top.
This takes longer to fit than an EDW or EDL kit, because every soaker is placed by hand as the tiles go back. It is also the most discreet finish on a plain tile roof, since the tiles run right up to the frame at their normal gauge.
Standard or recessed: what the last four digits change
The same flashing type comes in a standard version and a recessed version, and the choice shapes how the window looks from outside, how it performs at the edges and how the lining meets it inside.
A standard installation (code 0000) sets the frame at the depth VELUX treats as normal for that covering. Part of the frame and sash sits proud of the tiles or slates. It is the default on most roofs and is quick to fit.
A recessed installation (code 2000) lowers the window further into the roof so the frame sits closer to the line of the covering. On a slate roof the effect is a flatter, more discreet window, which is one reason it is chosen on terraces where the rear slope is visible from the street or from neighbouring gardens. A recessed window also presents slightly less of its frame to the weather.
- Rafter beside the opening, with insulation between the rafters.
- Trimmers across the rafters above and below the window, set back so they sit clear of the splayed lining.
- Battens and breathable underlay, the underlay turned up around the frame.
- Slates or tiles, cut and re-laid around the window.
- Flashing kit: an apron dressed over the slates below the window, and a head flashing tucked under the slates above.
- Insulation collar packed around the frame so the cold bridge at the opening is closed.
- Vapour control layer lapped to the frame with a collar, keeping warm, moist room air out of the roof.
- Lining: level at the head and plumb at the sill, so the opening widens into the room and throws more light down.
- Roof window: frame, sash and a sealed glazed unit, sitting a little above the slates in a standard fitting.
Recessed installation is not always the right call. It needs the battens and the fixing brackets set to a different depth, and the internal lining has to suit the lower frame. On a steep slope in an exposed position the extra neatness is well worth it; on a shallow roof or where the covering is thick, a standard installation may be the better match. It is also worth being clear that recessing a window does not by itself make it a conservation window. The VELUX conservation windows guide covers what planners in the city's conservation areas tend to look for, and whether a recessed standard window is enough or a dedicated conservation product is expected. For the planning side of a new window more generally, see do you need planning permission for VELUX windows.
Replacement flashings for older windows
When an older VELUX window is renewed, the flashing type decides how much of the inside of the room is disturbed. For windows made before 2001, VELUX offers specific replacement flashings that keep the new window at the old installation depth.
The reason is geometry. Windows from before the 2001 change were set at a different depth in the roof. If you fit a current window with a current flashing into that old opening, the frame sits at a new depth and the plaster lining around the window, inside the room, no longer lines up. That means cutting and making good the reveal. The replacement flashings, known by codes such as EW for tiles and EL for slate, are designed so the new window sits where the old one did, and the lining can stay as it is.
For windows from 2001 onwards, the standard current flashings are normally compatible, and a like-for-like swap uses the matching EDW, EDZ, EDL or EDS kit. The age of the window therefore affects not only the glass and the operation but the whole cost and mess of the job. The full picture of what changes when an old window is swapped is in the guide to replacing an old VELUX window, and will a new VELUX fit my old opening answers the sizing question directly.
Replacement is also the moment to reconsider the flashing type itself. If the roof has been re-covered since the window went in, the old flashing may belong to a covering that is no longer there. And if the old window was fitted without an insulation collar, the renewal is the chance to add one: the guide to VELUX insulation collars and installation kits explains why that matters for cold spots around the frame.
Combination flashings, pitch and roof details
Two windows side by side, or one above the other, need a combination flashing rather than two single kits. The combination parts fill the gap between the frames so water is carried across both windows as one.
Combination flashings use the K code, for example EKW for tiles and EKL for slate. They are made for set spacings between windows, and those spacings are fixed when the rafters are trimmed, so the flashing is part of the structural plan rather than something chosen at the end. A pair of windows in a loft conversion on a Chesterton terrace, for example, needs the spacing agreed before the roof is opened. If you are thinking of adding a window beside an existing one, adding a second VELUX window covers how the flashing and rafters are kept right.
Pitch matters too. VELUX roof windows are designed for a stated range of roof pitches, and the flashing's ability to shed water is part of that rating. Low-pitched roofs, such as a lean-to over a kitchen extension, slow the water down and increase the chance of wind pushing it uphill. Those roofs need careful checking against the manufacturer's minimum pitch for the window and flashing together. Tiles themselves have minimum pitches, and on a shallow lean-to the covering may already be close to its limit before any window is added.
There are also details the kit does not solve on its own. Where a window sits close to a hip, valley, chimney or abutment wall, the flashing has to be integrated with the lead or other detailing already there. Those parts are dressed by hand, and they are a large part of why fitting time varies from roof to roof.
How we choose the flashing on a Cambridge roof
The flashing is never chosen from a product list alone. We look at the covering, measure its profile or thickness, check the pitch and the details around the window, and then match them to the current VELUX data.
On a survey the order is roughly this:
- Identify the covering: real slate, artificial slate, plain tile, pantile or interlocking concrete tile, and whether any of it has been replaced over the years.
- Measure the profile height or thickness against the limits VELUX publishes for each kit.
- Check the pitch and exposure, including how far the slope is open to the south-westerly wind that crosses the flat land around Cambridge.
- Decide on standard or recessed depth, taking into account how the window will look from the street and how the lining inside will be finished.
- For a replacement, confirm the age of the old window and whether a replacement flashing will keep the existing lining.
That decision goes into the written light plan that comes with every quote, next to the window position, size, glass and blind. The VELUX window installation process guide shows where the flashing fits into the day itself, and the main VELUX window installation page sets out how we work across Cambridge and about 30 miles around. When you are ready, book a light survey through the form at the quote section or message us on WhatsApp.
Questions people ask
Can I reuse my old VELUX flashing with a new window?
Generally not. The flashing is shaped to the frame it came with, and fixing brackets, gaskets and profiles differ between generations. A new window is fitted with a new flashing of the right type, either a current kit or, for pre-2001 windows, a replacement flashing designed to keep the old installation depth.
Is EDW better than EDZ?
Neither is better in general; they suit different profiles. EDW's pliable apron fits deep and uneven tiles more closely, while EDZ is a simpler kit that works well on moderate, regular profiles. The measured tile profile, checked against VELUX's current limits, decides it.
Does a recessed flashing make the window conservation-compliant?
Not on its own. A recessed installation sits lower and looks neater, which some planners welcome, but conservation areas and listed buildings may expect a dedicated conservation window. The local planning authority's view is what counts, and we check it before the order is placed.
Which flashing suits a roof with artificial slates?
Many artificial and fibre cement slates are thin enough for EDL. Some slate-effect concrete tiles are much thicker and need a tile flashing. Measuring the actual product on the roof is the only reliable way to tell.