Question

Do roof lanterns get condensation?

The short answer

Yes, a roof lantern can get condensation, most often on winter mornings over a busy kitchen. Warm, damp air rises to the highest and coldest surface in the room, and on an older lantern that is the glass. A modern lantern with a warm inner pane, a thermally broken frame and a proper route for moist air to leave the room keeps it to a rare, brief film.

Why the moisture ends up on the lantern

Condensation forms wherever air meets a surface colder than its dew point, and a lantern sits exactly where the warmest, wettest air in the house collects.

Cooking, a kettle, a dishwasher opening at the end of its cycle, drying laundry and several people breathing all put water vapour into the air. Warm air holds more of it than cool air, and warm air rises. In a kitchen extension with a lantern, that plume drifts up past the ceiling line and into the light well, where it meets glass that is facing a clear night sky.

The Cambridge climate adds to it. The land around the city is flat and open, so on still, clear winter nights nothing shelters the roof and the glass loses heat quickly to the sky. By seven in the morning the outer pane can be well below the air temperature in the garden, and an older inner pane follows it down. Switch on the hob for breakfast and the moisture has a cold surface waiting for it.

A lantern is not unusual in this. A cold wall behind a wardrobe or the reveal of an old sash window does the same thing. The lantern is simply the part of the room people look at, so the droplets are noticed, and because it is overhead the water can run down the bars and drip, which a wall does not do.

Where the droplets form, and what each place tells you

The spot where the moisture appears is the most useful clue, because each position points to a different cause and a different answer.

Where you see itLikely causeWhat helps
Across the inner paneVery humid room, cold glassExtraction, vents, warmer glazing
A band round the glass edgeCold spacer bar in the unitWarm-edge spacers
On the bars and ridgeFrame with no thermal breakThermally broken frame
Between the two panesFailed edge sealReplace the glazed units or lantern

The first three are room-side condensation, which is about the balance of humidity and surface temperature. The fourth is different. Mist trapped inside a sealed unit means the seal has let moist air in and the desiccant in the spacer is saturated. Wiping and ventilating will not touch it, and the unit has lost much of its insulating value, so the sensible course is to replace the units or, on an older lantern with cold aluminium bars, to renew the whole lantern.

What the glazing and frame change

The warmer the inner surface of the lantern stays, the more humid the room has to be before anything forms on it, and modern glazing raises that surface temperature a long way.

A single-glazed or early double-glazed lantern can have an inner pane only a few degrees warmer than the outside air on a frosty night. A current double-glazed unit with a low-E coating, an argon-filled cavity and warm-edge spacers keeps the inner pane much closer to room temperature, because the coating reflects the room's own heat back in and the gas slows the loss through the cavity. Triple glazing raises it again, which helps in a kitchen that runs very humid.

The frame matters as much as the glass. Aluminium conducts heat readily, so an aluminium lantern without a thermal break has bars and a ridge that run close to outdoor temperature, and droplets line up along them. Current aluminium lanterns separate the inner and outer parts of each bar with an insulating break, and uPVC is a poor conductor to begin with. The comparison of aluminium and uPVC lanterns covers how each frame behaves, and the roof lantern glass options guide sets out double against triple glazing.

The upstand and the light well are part of the same picture. An uninsulated kerb or a light well lined with bare plasterboard over a cold void gives moisture a cold strip just below the glass. When we fit a lantern the upstand is insulated and the reveal is lined and plastered, which is one reason how a lantern is finished inside is worth thinking about early.

Getting the damp air out of the kitchen

Better glass raises the threshold; ventilation lowers the humidity. The two work together, and neither does the whole job alone.

The biggest single step is a cooker hood that is ducted to the outside and switched on before the pans boil, not after. A recirculating hood filters grease and smells but returns the water vapour to the room. Approved Document F expects a kitchen to have extract ventilation, and a new extension is a good moment to make sure it is ducted and sized for the space rather than carried over from a smaller room.

An opening vent in the lantern itself is the next tool. Warm, moist air collects at the top of the light well, so a vent at the ridge or in a hip lets it leave from the very place it gathers. An electric vent with a rain sensor can be left on a timer in the morning without anyone climbing up to it, and whether roof lanterns can open explains the manual and electric choices. Trickle vents in the doors or windows give a small, steady background air change that keeps humidity from building overnight.

Heating plays a part too. A room that is allowed to go cold overnight and then heated fast in the morning is at its worst for condensation, because the air warms and fills with steam before the glass has caught up. A steadier background temperature through winter keeps the glass warmer and the problem smaller.

Blinds, orientation and the morning light

The light plan for a lantern also affects condensation, because anything that keeps the glass colder or traps air against it makes droplets more likely.

A blind drawn across the underside of a lantern on a winter night holds a layer of air between the fabric and the glass. That air is cut off from the room's heat, the glass cools further, and the moisture that reaches it has nowhere to go. If you have lantern blinds, opening them in the morning lets warm air wash across the glass again. Whether roof lanterns need blinds looks at when they earn their place.

Orientation shifts things a little. Low morning sun on an east-facing roof warms the glass early and clears a light film within an hour or so, while a lantern on a north-facing extension sees little direct sun in winter and stays cooler for longer. That is not a reason to avoid a lantern on a north side, only a reason to specify a warmer glass unit there and to put the vent where it will actually be used. It also connects with winter comfort: the same cold inner surface that collects droplets drives the draught described in do roof lanterns make a room cold.

Questions people also ask

Is a little condensation on a roof lantern normal?

A light film on the inner glass on a cold morning after cooking is normal physics and clears as the room and glass warm. Water that runs down the bars and drips most days, or mist that never clears, is a sign the room is too humid, the lantern is too cold, or both.

Does misting between the panes mean the lantern has to be replaced?

It means the sealed unit has failed. On a sound, reasonably modern frame the glazed units can sometimes be renewed on their own; on an older lantern with cold, unbroken bars, replacing the whole lantern usually gives a far better result for the room below.

Will triple glazing stop condensation completely?

It lowers the risk a great deal by keeping the inner pane warmer, but no glass copes with a kitchen full of steam and no extraction. Pair it with a ducted hood and an opening vent.

Can condensation damage the ceiling around a lantern?

Regular dripping can mark paint and plaster in the light well over time, which is why the room-side causes are worth tackling. If you are planning a new or replacement lantern, our roof lantern installation page explains how we specify the glass, frame and venting, or you can book a light survey.

Book a light survey

Tell us about the room

  • No obligation
  • Light plan in writing
  • 10-year guarantee
Book a survey Call