Guide · Energy efficient rooflights

Low-E Coatings and Argon Fill

A modern rooflight insulates because of two things you cannot see: a coating thinner than a soap film and a gas sealed between the panes. Here is what each one does, and what it means for the room below.

14 min read10 chapters

Two invisible layers doing the real work

A modern sealed rooflight owes its insulation to two things you cannot see: a metal oxide coating a few hundred atoms thick on one pane, and a heavier-than-air gas sealed into the gap between the panes. Take either away and the same skylight loses heat noticeably faster.

Look up through a new rooflight and it reads as plain, clear glass. Look at it from outside at a low angle on a bright day and you may catch a faint sheen, slightly silver or slightly green depending on the product. That sheen is the low-emissivity coating, usually shortened to low-E. Tap the edge of the unit and nothing tells you what is in the cavity, but in a current double or triple glazed rooflight the space between the panes is almost always filled with argon rather than ordinary air.

Neither of these is an optional extra in the way that self-cleaning glass or an electric blind is. They are the reason a double glazed unit can now reach a centre-pane U-value around 1.0 to 1.2 W/m²K in the vertical position, when the same two panes of clear glass with air between them would sit closer to 2.7. They also decide how warm the inner pane feels on a February morning, how much of the sun's heat reaches the room, and in some cases whether dew forms on the outside of the glass. This guide explains what each layer does, where it sits in the unit and what it means for the light and comfort in the room below. For the wider picture of how glass, frame and upstand combine, the energy efficient rooflights service page sets out how we specify a whole unit.

How heat actually crosses a pane of glass

Heat leaves a room through a skylight in three ways at once: conduction through the glass and gas, convection currents inside the cavity, and long-wave infrared radiation passing from the warm inner pane to the cold outer one. Low-E coatings attack the third route and argon slows the first two.

It helps to separate the three because each layer answers a different one. Glass itself is a poor insulator, but it is thin, so the pane barely matters on its own. The cavity is where the insulation happens. Across a sealed gap of 12 to 16 mm, heat moves by conduction through the still gas, by slow convection as gas warmed by the inner pane rises and gas cooled by the outer pane sinks, and by radiation straight across the gap.

Radiation is the largest of the three in an uncoated double glazed unit. Ordinary float glass has an emissivity of about 0.84, meaning its surface radiates heat almost as readily as a theoretical perfect emitter. The warm inner pane glows in the infrared, the cold outer pane absorbs that energy and sheds it to the sky, and in a unit with two clear panes this radiant exchange accounts for roughly two thirds of the heat crossing the cavity. That is why a coating that stops the glow is so effective, and why gas fill on its own, without a coating, gives only a modest improvement.

Once radiation has been cut back, the remaining heat moves through the gas. Here the choice of gas and the width of the gap take over, which is where argon comes in.

What a low-E coating is and where it sits

A low-E coating is a microscopically thin layer of metal and metal oxide applied to one face of a pane, transparent to visible light but highly reflective to long-wave heat. It is placed on a surface facing into the sealed cavity, where it is protected from weather, cleaning and condensation.

There are two broad families. Hard-coat, or pyrolytic, low-E is fused onto the glass while it is still hot on the float line. It is durable enough to handle and has an emissivity of roughly 0.15 to 0.2. Soft-coat, or sputtered, low-E is applied afterwards in a vacuum chamber, building up several layers that include a film of silver. It performs far better, with emissivity typically in the range 0.02 to 0.05, but it is delicate and would oxidise if exposed to air and moisture. So soft coatings only ever face into the sealed cavity, and the coating is stripped from a narrow band around the edge of the pane (edge deletion) so that the spacer and seals bond to bare glass.

Glazers number the faces of a sealed unit from the outside in. In a double glazed rooflight, surface 1 faces the weather, surfaces 2 and 3 face the cavity, and surface 4 faces the room.

Exploded view of a double glazed and a triple glazed rooflight unit, showing the outer toughened pane, coatings, argon cavities, warm-edge spacers and the inner laminated pane.×2×31234567
Fig. Exploded double glazed (left) and triple glazed (right) rooflight units, outside on the left.
  1. Outer toughened pane: heat-strengthened to take hail, foot traffic during maintenance and thermal stress.
  2. Solar-control coating (optional) on the inside face of the outer pane, cutting heat gain on south and west roofs.
  3. Argon-filled cavity: a denser gas than air, so less heat crosses the gap.
  4. Warm-edge spacer: a low-conductivity edge that keeps the units’ edges warmer and cuts condensation at the frame.
  5. Low-E coating: a microscopically thin metal layer on a cavity face that reflects room heat back inside.
  6. Inner laminated pane: two sheets bonded to an interlayer, so if it ever breaks, the glass stays in place overhead.
  7. Triple glazing only: a third pane and a second argon cavity, usually with a second low-E coating. Warmer, heavier, and it lets in slightly less light.
  • Surface 2 (inner face of the outer pane) is where a combined solar control and low-E coating usually goes. Here it reflects solar heat before it has entered the cavity, which keeps summer gain down.
  • Surface 3 (cavity face of the inner pane) is the classic position for a pure heat-retaining coating. It keeps the room's radiant heat on the room side and lets more winter sun through.
  • Triple glazing has two cavities and normally carries two coatings, one per cavity, which is a large part of why its U-value is lower.

Which surface is used depends on the product and the glass make-up, and we read it from the unit's specification rather than assume it. The position matters to the room, as the sections on sunlight and outside dew show.

Argon, krypton and the width of the gap

Argon is an inert, colourless, non-toxic gas that conducts heat about a third less readily than air. Filling the cavity with it cuts conduction and slows convection, and the gain is largest once a low-E coating has already dealt with radiation.

Argon makes up a little under one per cent of the air we breathe and is separated out industrially in large volumes, which is why it is the standard fill. Its thermal conductivity is around 0.016 to 0.018 W/mK, against roughly 0.025 for dry air. Being a heavier gas it also circulates more sluggishly, so the convection loop inside the cavity carries less heat. Units are filled during manufacture to a high concentration, commonly specified at 90 per cent or more, and the edge seal is what keeps it there.

Krypton goes further, with a conductivity near 0.009 W/mK, but it is rare and costly. Its advantage is that it performs best in a narrower gap, so it turns up in slim triple glazed units and in conservation rooflights where the overall glass depth has to stay small to fit a slender frame. Xenon exists as a fill in principle but is not something a homeowner is likely to meet.

Gap width is a balance. Too narrow and the gas conducts heat straight across; too wide and a convection current gets going and carries heat round the loop. For argon in a vertical window the sweet spot is usually around 15 to 16 mm, and for krypton nearer 10 to 12 mm. A rooflight is not vertical, and that changes the arithmetic, as the next section explains. The spacer that holds the gap and carries the seal is covered in its own answer on warm edge spacers, and the gradual reduction of fill over the life of a unit is covered in does argon gas escape from rooflights.

Why the same unit performs worse lying flat

A sealed unit laid close to horizontal, with the warm pane underneath, sets up a stronger convection current in the cavity than the same unit standing upright. The coating still works, but the gas has to do more, and centre-pane figures rise by roughly 0.3 to 0.5 W/m²K.

In a wall window, warm gas rises up the inner pane and cold gas falls down the outer one in a tall, slow loop. Turn the unit flat, with the warm pane below and the cold pane above, and warm gas rises straight across the gap into the cold pane, cools, and drops back. The cells of circulating gas are short and busy, much like water heated from below in a pan. More heat crosses the cavity as a result.

The figures below are indicative centre-pane U-values for common double glazed make-ups with 4 mm panes, drawn from standard glass calculation methods. They are a guide to the size of each effect, not the rating of any particular product.

Make-upUprightFlat
Clear, air, 16 mmabout 2.7about 3.0
Low-E, air, 16 mmabout 1.4about 1.8
Low-E, argon, 16 mmabout 1.1about 1.5
Low-E, krypton, 10 mmabout 1.0about 1.3

Two things follow. First, the coating does the heavy lifting and the gas then adds a further worthwhile step. Second, a gap that is ideal upright may not be ideal lying flat, which is why good flat rooflight manufacturers tune their cavity widths for the angle the unit is actually fitted at. Since the 2021 changes to Part L, rooflight U-values are assessed in the horizontal plane, so the figure on a current datasheet should already reflect this. Our guide to rooflight U-values explains how to tell a horizontal whole-unit figure from a flattering upright centre-pane one, and the Part L requirements guide covers the limiting value a replacement has to meet.

What the coating does to sunlight and daylight

A low-E coating is designed to pass visible light and block long-wave heat, but it cannot be perfectly selective. It trims a little daylight, it trims more of the sun's near-infrared heat, and the surface it sits on decides how much of that summer heat reaches the room.

Sunlight arriving at the glass is mostly visible light and short-wave infrared. The heat radiating from a warm room, a radiator or your own skin is long-wave infrared, a very different part of the spectrum. A heat-retaining soft coat reflects the long-wave heat strongly and lets most of the visible light through, so a clear double glazed unit with argon and one coating typically transmits somewhere around 70 to 80 per cent of visible light, against the low 80s for two panes of clear glass. In a room lit from above you are unlikely to notice that difference by eye, though a low-iron outer pane can win some of it back.

The solar heat figure, the g-value, moves more. Clear double glazing lets through roughly three quarters of the sun's energy. A standard low-E unit is nearer 0.5 to 0.6, and a combined solar control coating on surface 2 can bring it down to 0.3 or lower while still passing a useful share of daylight. This is where a coating stops being a winter insulation feature and becomes a summer comfort decision, and the choice belongs to the slope and the room rather than the catalogue.

For north slopes and rooms that already struggle for light, a heat-retaining coating with the highest light transmission available is usually the right starting point. For south and west slopes, especially over a bedroom, a desk or a kitchen island, the coating is part of the glare and heat plan. The detail of that trade-off sits in our guides to solar control glass and g-value and light transmission.

Warmer inner glass, and dew on the outer pane

By holding the room's heat on the room side, a low-E and argon unit keeps the inner pane several degrees warmer than older glazing. The side effect is a colder outer pane, and on a clear, still night a rooflight facing the open sky can collect dew or frost on the outside.

The inner pane is the one you feel. On a cold night an old single glazed skylight can sit only a few degrees above the outside temperature, which is why the air under it chills, sinks and makes the room feel draughty. A modern double glazed unit with a soft coat and argon keeps the inner surface far closer to room temperature, so that cold fall of air is much weaker and the pane is less likely to drop below the dew point of the room air. Our guide to rooflight condensation covers the inside surface, the frame and ventilation in more detail.

Outside, the picture reverses. Because so little heat leaks through, the outer pane stays close to the air temperature and, facing a clear sky, can radiate its warmth away until it falls below it. Dew then forms on surface 1, exactly as it forms on a car roof or a lawn. It is a sign that the unit is insulating well, not a fault, and it clears as the morning warms up. A flat rooflight looks at the whole sky, and the big open skies over the Fens make clear, still nights common in spring and autumn, so it is more likely here than on a wall window. A self-cleaning or hydrophilic outer coating helps dew sheet off rather than bead, and a slight fall on the glass helps it run clear.

What you can and cannot do with an older unit

Neither a coating nor argon can be added to a sealed unit after it has been made, and neither can be topped up in place. If an older skylight lacks them, the route to the benefit is a new sealed unit or a new rooflight.

It is difficult to tell by eye what an existing unit contains. Some manufacturers print the make-up on the spacer bar inside the unit, and a glazier can confirm a coating with a simple meter that reads which surface carries one. Argon content can be checked with a non-destructive gas analyser shone through the glass, although few homeowners will have this done. A unit from the 1990s may well have air in the cavity and a hard coat or none at all, while older wired glass and single glazed units have neither.

Misting between the panes is the plainest sign that an edge seal has failed. Once moist air has entered the cavity, whatever argon was there has been diluted and the coating may start to degrade, and the unit will not recover. That calls for a replacement, and depending on the frame that may be the sealed unit alone or the whole rooflight. Our guides on upgrading single-glazed rooflights and double versus triple glazing help with the decision about what to replace it with.

Window films sold as retrofit low-E are applied to the room face of the glass, which is the worst place for them on a sealed unit. They can raise the temperature of the inner pane in sunshine and put stress on the seal, and they can affect the manufacturer's glass warranty.

Reading the glass line on a specification

A rooflight glazing specification written as a line of numbers and letters tells you the pane thicknesses, the gap, the gas and the coatings. Knowing how to read it lets you compare two quotes like for like.

A typical line might read 6 mm toughened solar control low-E, 16 mm argon, 6.8 mm laminated. From the outside in, that is an outer pane with a coating (the wording implies surface 2), a 16 mm cavity filled with argon, and an inner laminated pane that holds together if broken. A triple unit adds a middle pane, a second cavity and usually a second coating. Beside the make-up, a good datasheet should give you four figures:

  1. The whole-unit U-value, stated in the horizontal plane or at the fitted pitch.
  2. The g-value, so you know how much solar heat will reach the room.
  3. The light transmission, so you know how much daylight you keep.
  4. The gas fill and spacer type, since both affect edge temperature and life.

If a quote gives only a centre-pane figure measured upright, or does not say whether the cavity is argon or air, ask. The difference between two apparently similar units can be a whole coating or a gas fill, and it shows up in comfort for the next twenty years. On every job we set these figures out in the written light plan, with the reason for each choice against the slope and the room, as described on how we plan the light.

Questions people ask

Does a low-E coating wear off?

Not in normal use. A soft coating sits inside the sealed cavity, where nothing touches it, and a hard coating is fused into the glass surface. The coating is only at risk if the edge seal fails and moist air gets into the cavity, at which point the unit needs replacing anyway.

Will a low-E skylight look tinted from inside the room?

A heat-retaining low-E coating on its own is close to neutral, and in daylight from above it is hard to notice. Stronger solar control coatings can give a slight blue, grey or green cast, and a sheen from outside. If colour matters, for a studio or a kitchen with pale finishes, ask for a neutral coating and see a sample in daylight.

Is argon fill dangerous if a rooflight breaks?

No. Argon is a normal part of the air, it is inert and non-toxic, and the small amount in a cavity disperses harmlessly the moment a pane is broken. The real safety issue with overhead glass is the glass itself, which is why the inner pane of a rooflight should be laminated.

Is krypton worth paying extra for?

Only where the glass depth is limited. In a standard rooflight with room for a 14 to 16 mm cavity, argon gets most of the benefit. Krypton earns its cost in slim conservation units and some triple glazed units where the gaps have to stay narrow. If you want to talk through the glass for a particular roof, book a light survey and we will set it out in writing.

Book a light survey

Tell us about the room

  • No obligation
  • Light plan in writing
  • 10-year guarantee
Book a survey Call