Two numbers on every glass data sheet
Every rooflight or skylight unit has a g-value, which tells you how much of the sun's energy gets through as heat, and a light transmission figure, which tells you how much visible daylight gets through. Choosing glass is mostly a matter of setting those two against each other for the slope you have.
The g-value, sometimes written as total solar energy transmittance, is a fraction between 0 and 1. A g-value of 0.60 means that 60% of the solar energy striking the outside of the glass ends up inside the room. That total has two parts: the energy that passes straight through the panes as radiation, and the heat that the glass itself absorbs and then gives off towards the inside. Both count, because both end up warming the room.
Light transmission, shown as LT, Tv or τv on European data sheets, is also a fraction or a percentage. It measures only the visible part of the spectrum, weighted to match the sensitivity of the human eye. An LT of 70% means the glass passes seven tenths of the daylight that falls on it. This is the number that decides how bright the room feels, how far the light reaches across the floor and how much you will need the ceiling lights on a grey January afternoon.
Both figures are worked out to a European standard, BS EN 410, for light arriving square on to the glass. That detail matters on a roof, as we explain below. The U-value, which describes heat escaping outwards through the unit, is a separate measure altogether; our guide to rooflight U-values covers it. A unit can have an excellent U-value and still let in far too much summer heat, or the reverse.
Why daylight and heat are not the same thing
Sunlight carries roughly half its energy in the visible band and most of the rest in the near infrared, which you feel as warmth but cannot see. Modern coatings exploit that split, holding back infrared while passing as much visible light as they can.
Plain clear glass does not discriminate much. It lets through most of the visible light and most of the infrared, so its g-value and its light transmission sit close together. Add a low-emissivity coating and the g-value drops a little while the light hardly changes. Add a solar control coating, a thin stack of metal and metal oxide layers on one face inside the sealed unit, and the g-value can fall a long way while the light falls by much less.
The useful way to compare glass is the ratio of the two, often called selectivity or the light to solar gain ratio: LT divided by g. Clear double glazing comes out a little above 1. A good low-E unit sits around 1.3. Well-made neutral solar control glass reaches roughly 1.8 to 2, and physics puts a ceiling not far above that, because some of the sun's energy is visible light and any glass that passes light must pass that energy too. So when a supplier offers a glass with a very low g-value, check its LT next to it. If the ratio is poor, the glass is simply dark, and a dark glass cuts heat by cutting daylight, which is the thing you paid for the rooflight to deliver.
Tinted body glass, the older bronze and grey types, works this way. It absorbs energy in the glass itself and cuts light almost as much as heat. Most current solar control glass for rooflights uses reflective coatings instead, which is why it can look fairly clear from inside while still doing its job.

Typical figures for common rooflight glass
The figures below are broad, typical ranges for sealed double and triple units. Each manufacturer publishes its own, and they vary with coating, pane thickness and whether the inner pane is laminated.
| Glass make-up | Light (LT) | g-value | Ratio |
|---|---|---|---|
| Clear double, no coating | about 80% | 0.72 to 0.77 | about 1.1 |
| Double, low-E | 75 to 80% | 0.55 to 0.63 | about 1.3 |
| Triple, low-E | 65 to 73% | 0.45 to 0.55 | about 1.4 |
| Double, neutral solar control | 55 to 70% | 0.28 to 0.40 | 1.7 to 2.0 |
| Double, strong solar control | 35 to 50% | 0.20 to 0.28 | 1.6 to 1.8 |
Three things stand out. Triple glazing already cuts solar gain compared with double, because each extra pane and coating takes a share of both light and heat; double against triple is partly a light decision for that reason. Low-E on its own is not solar control: it is there to keep winter heat in, and it only trims summer gain. And the strongest solar control glass has a worse ratio than the neutral grades, so it buys its last few points of heat reduction with a lot of daylight.
A laminated inner pane, which overhead glazing needs for safety, lowers LT by a point or two and blocks almost all ultraviolet. Low-iron outer glass nudges LT up and removes the faint green cast of ordinary float glass. Neither changes the picture much on its own, but together they can move a unit a few percent either way.
- Outer toughened pane: heat-strengthened to take hail, foot traffic during maintenance and thermal stress.
- Solar-control coating (optional) on the inside face of the outer pane, cutting heat gain on south and west roofs.
- Argon-filled cavity: a denser gas than air, so less heat crosses the gap.
- Warm-edge spacer: a low-conductivity edge that keeps the units’ edges warmer and cuts condensation at the frame.
- Low-E coating: a microscopically thin metal layer on a cavity face that reflects room heat back inside.
- Inner laminated pane: two sheets bonded to an interlayer, so if it ever breaks, the glass stays in place overhead.
- Triple glazing only: a third pane and a second argon cavity, usually with a second low-E coating. Warmer, heavier, and it lets in slightly less light.
Flat glass faces the summer sun head on
A wall window in June sees a high sun at a steep, glancing angle, which it partly reflects. A rooflight on a flat roof or a low pitch sees that same sun almost square on, which is exactly the angle at which g-values are measured, so it takes in close to the full published figure at the hottest time of year.
In Cambridge the midsummer sun climbs to about 61 degrees above the horizon at midday. For a vertical south window that is a shallow angle of incidence; for a flat rooflight it is not far from overhead. In December the noon sun is only about 14 degrees up, so the position flips: the wall window catches the low winter sun well and the flat rooflight catches very little. Horizontal glass therefore gathers most of its solar energy in the months when you least want it and gives back least in the months when you would welcome it.
The flat land around the city adds to this. With no hills and few tall buildings to the south of most homes in Chesterton, Cherry Hinton or the new streets at Eddington, a roof sees the whole sun path from sunrise to sunset. A rooflight over a single-storey kitchen extension in a Romsey terrace may get some shade from the neighbouring wall in the morning, but by early afternoon it will be taking full sun.
This is why the same g-value that suits a wall of glazing can be too high for a roof, and why our guide to rooflight overheating in summer treats roof glass as its own problem rather than a scaled-up window.
Setting the balance by orientation
The right pair of figures depends on which way the glass faces, how steep it is and what the room is for. A kitchen you cook in at 6pm and a loft bedroom you sleep in need different answers even on the same slope.
North-facing slopes
A north-facing roof window gets soft, even sky light for most of the day and very little direct sun, except in the early morning and late evening around midsummer. Here the priority is light, not heat control. A standard double or triple low-E unit with the highest LT you can get is usually the better choice, because a solar control coating would take daylight away from a room that has none to spare and protect it from a sun that rarely arrives. Heat loss matters more than heat gain on this side, as our answer on north-facing rooflights explains.
East and west
East glass takes the morning sun, which is lower and cooler, and the room has the rest of the day to lose the heat. West glass takes the late afternoon sun after the room and the roof have already warmed up, which makes it the harder side to keep comfortable. A west-facing skylight over a living room or a home office often suits a moderate solar control glass, somewhere near a g-value of 0.35 to 0.45, while east glass over a kitchen can often stay with a good low-E unit.
South-facing slopes and flat roofs
South slopes and flat roofs are where g-value does most of the work. On a flat rooflight or lantern over an open-plan kitchen, a neutral solar control unit with a g-value in the region of 0.30 to 0.40 and an LT of 60% or more keeps the light while taking the edge off the heat. We set out how to pick a figure for this side in what makes a good g-value for a south-facing rooflight. Bedrooms on a south slope are the most demanding case of all, since the room is used in the evening and at night after a full day of gain, and there glass usually works best alongside external shading.
These are starting points, not rules. Room size matters too: a small rooflight in a large room adds little heat whatever its glass, while a lantern taking up a fifth of a kitchen ceiling is a significant heat source on a clear afternoon.
Reading a data sheet without being misled
Glass figures are easy to quote and easy to compare badly. A few checks make sure you are comparing like with like.
- Centre-pane or whole unit. Most g and LT figures describe the glass only. The frame blocks both light and sun, so a unit with a deep frame admits less of each than its glass figure suggests. That is not a bad thing for heat, but it matters for light.
- The same standard. BS EN 410 figures and those calculated under other methods can differ by a few points. Compare units measured the same way.
- External reflectance. Strong solar control glass can look mirrored from outside. In a conservation area, or on a front slope in De Freville or Newnham, that appearance can matter as much as the performance.
- Colour. Some coatings give a faint blue, green or grey cast, and a colour rendering figure (Ra) above 90 keeps food, skin and paint colours looking true. Our answer on blue or neutral solar control glass covers the difference in practice.
- UV transmission. A laminated inner pane blocks most UV, which helps with fading, although visible light and heat also fade fabrics over time.
Watch for the old "shading coefficient" too. It is the g-value divided by the g-value of a single clear pane, about 0.87, so it always reads a little higher than g. Mixing the two makes one glass look worse than it is.
What the eye notices, and what it does not
The human eye adapts quickly to overall brightness, so a change in light transmission of a few percent is hard to see. A drop from 78% to 65% is noticeable side by side, but in a room on its own it tends to read as calmer light rather than dim light.
That is why neutral solar control glass with an LT around 60% to 70% rarely feels dark under an open Cambridge sky, especially on a flat roof, which sees far more sky than a wall window does. It is also why very dark glass, below about 40%, often does. The room may feel shaded rather than lit, and on overcast winter days the difference becomes obvious. If you are worried about this, our answer to whether solar control glass makes a room darker goes into how it looks in practice.
What people do notice is glare and heat. A clear rooflight with a high g-value throws a sharp, hot sun patch across the worktop or the sofa, and that patch moves across the room through the day. Solar control glass softens its edges and cools it. It does not stop the patch, because a coated pane still passes direct sun. If the problem is where the sun lands rather than how hot it is, position and a blind will help more than a lower g-value.
The winter side of the equation
A low g-value is not free. The same coating that keeps out July heat also keeps out the small amount of useful winter sun that a well-placed skylight can provide.
On a flat roof in a Cambridge winter the loss is small, because the low sun barely reaches horizontal glass. On a steep south-facing roof window, perhaps at 45 degrees or more on a Victorian terrace, the winter sun arrives much closer to square on, and a clear low-E unit can pick up worthwhile heat on bright days. Our answer on whether a skylight can warm a room in winter looks at how much. For that kind of window, strong solar control glass may cost more comfort in winter than it saves in summer, and an external awning blind that comes off in autumn can be a better balance.
So choosing glass is really a decision across the whole year. The questions are how steep the glass is, which way it faces, when the room is used, and whether shading can do some of the work so the glass does not have to do all of it. External shading stops heat before it reaches the glass and can be taken away when you want the sun, which no coating can do.
How we choose glass for a light plan
At the survey we record the orientation and pitch of each proposed opening, the obstructions around it and how the room is used, and then pick the glass to suit rather than using one unit throughout the house.
A typical Cambridge extension might end up with three different glass choices: a neutral solar control lantern on the flat roof over the kitchen, a clear low-E roof window on the north slope of the loft for a study, and a moderate solar control unit on a west-facing slope over the stairs. Each is set out in the written light plan with its g-value, its light transmission and the reason for it, so you can see what you are buying and compare it with anything an architect or another installer proposes.
The same thinking runs through how we plan the light for any job, and the wider questions of U-values, Part L and frame design are covered from the energy efficient rooflights hub. If you have a slope in mind and want to know which figures would suit it, book a light survey and we will set the glass out in writing with the rest of the plan.
Questions people ask
Is a lower g-value always better for a rooflight?
No. A lower g-value cuts summer heat, but it also cuts winter solar gain and usually some daylight. On a north slope it can make a room darker for little benefit. The right figure depends on orientation, pitch and room use, and on how the light transmission compares.
Can I add solar control to an existing skylight?
Coatings are applied inside the sealed unit when it is made, so an existing unit cannot be given one. Applied films exist, but they can overheat and stress sealed glass. The reliable routes are external shading or replacing the unit with a correctly specified one.
What light transmission should I aim for?
For most living spaces, an LT of 60% or more keeps a room feeling bright under a Cambridge sky. North-facing rooms and deep terraced plans benefit from the highest figure available, while a sunny flat roof can accept a little less in exchange for a lower g-value.