Guide · Sun tunnels

Sun Tunnel Ventilation Kits

A windowless bathroom needs light and it needs the steam gone. A sun tunnel ventilation kit can do both through one round fitting, if the air route is planned as carefully as the light.

15 min read11 chapters

One ceiling fitting, two jobs

A sun tunnel ventilation kit pairs a tubular skylight with an extract route, so a windowless bathroom gets daylight and a way to clear steam through a single round fitting in the ceiling.

The basic sun tunnel is sealed from top to bottom. The dome on the roof, the reflective tube and the diffuser in the ceiling form a closed light path, and no air passes through it. That is deliberate: a sealed tube keeps warm, damp room air out of the cold loft and stops dust settling inside the reflective lining. A ventilation kit adds a separate air path alongside the light path. In most designs a vent ring or grille sits around the diffuser, air is drawn into it, and it travels up a duct to an outlet on the roof or at the eaves.

Manufacturers approach the detail in different ways, and product ranges change, so treat what follows as a description of the common patterns rather than a promise about any one kit. Some systems draw the air up a sleeve that wraps around the light tube. Others take a flexible duct off the ceiling ring and route it through the loft to a separate tile vent or soffit outlet. Some are passive; others carry a small fan, either in the ceiling ring or inline in the loft. What they share is the look from below: one neat circle on the ceiling rather than a diffuser in one place and an extract grille in another.

If you are new to how the light side works, how sun tunnels work covers the dome, tube and diffuser. The sun tunnel installation hub explains where tubular skylights suit a Cambridge home in general. This guide is only about the bathroom, and about the air.

Why bathrooms are where these kits earn their place

An internal bathroom has two problems at once: no daylight and nowhere for shower steam to go, and a combined kit answers both through the same small hole in the ceiling.

Cambridge has plenty of these rooms. In the terraces of Romsey, Petersfield and the streets off Mill Road, the bathroom was often carved out of a back bedroom or squeezed into the middle of the plan when the outside toilet went, leaving it with no external wall. Loft conversions across Chesterton and De Freville frequently put an en-suite under the ridge, tucked behind the bedroom where a roof window will not reach. Newer homes at Eddington, Trumpington Meadows and Great Kneighton have en-suites and shower rooms in the centre of the plan, lit only by a downlight and ventilated by a fan that clicks on with the light switch.

In all of these, a sun tunnel changes the character of the room. Daylight through a diffuser is soft and even, it shows true skin tones at the mirror, and it means you do not need the electric light on for a morning shave in June. But the room still produces a lot of moisture, and a new opening in the ceiling is a natural moment to sort out the extract as well. Running both through one fitting keeps the ceiling tidy, which matters in a small room where two circles and a light fitting can start to look cluttered.

Kitchens are a different case. Cooking needs a cooker hood or an extract rated for a kitchen, and a sun tunnel there is about lighting a dark corner or island. The guide on whether a sun tunnel can go in a kitchen covers that; ventilation kits are really a bathroom, en-suite, shower room and utility product.

What the Building Regulations ask of a bathroom

Approved Document F sets the ventilation expected in a bathroom, and the usual benchmark for an intermittent extract fan is 15 litres per second, with Building Control having the final say on what your particular room needs.

Approved Document F is the government guidance that shows one way of meeting Part F of the Building Regulations, which deals with ventilation. For a bathroom it sets out a minimum extract rate. For an intermittent fan, one that runs when the room is in use and then switches off, the figure generally used is 15 l/s. Continuous systems, which run at a low trickle all the time and boost when needed, are assessed against different figures, and whole-house ventilation in a newer home may already be designed to serve the bathroom.

A few points follow from that benchmark, and they are worth understanding before choosing a kit:

  • The rate is measured at the room, not on the box. A fan's catalogue figure is usually tested with no duct attached. Every metre of duct, every bend and the outlet itself reduce the air actually moved, so a kit that looks comfortable on paper can fall short once installed.
  • A passive vent may not reach it. A kit with no fan relies on warm, damp air rising on its own. That helps, but it may not deliver a dependable rate, so in a room with no openable window Building Control may look for a powered extract.
  • Run-on matters in a room without a window. Guidance generally expects a fan in a windowless bathroom to keep running for a period after the light goes off, commonly 15 minutes, so the steam clears after you have left.
  • Air needs a way in. Extract only works if replacement air can reach the room, which is normally a gap under the door. A new, tight-fitting door with no undercut can starve the fan.

Whether the work is notifiable, and what evidence is needed, depends on the scope. A new roof opening, a new extract and any electrical work in a room with a bath or shower can each bring the Regulations into play. We handle the Building Control notification where the work is notifiable, and the electrical side is carried out by a qualified electrician, who issues the paperwork for it. For the light fitting alone, do sun tunnels need building regulations explains where the line usually falls. The figures in this section are the published benchmark; the decision on your room sits with Building Control.

The ways a kit can move the air

Ventilation kits fall into three broad patterns: passive, fan in the ceiling ring, and fan inline in the loft, and each trades noise, extract rate and ease of fitting differently.

PatternHow air movesNoise in roomBest suited to
PassiveWarm air rises unaidedSilentRooms with other extract
Ceiling fanFan in the ringAudibleShort, simple duct runs
Inline fanFan in the loft ductQuietLonger runs, en-suites

A passive arrangement is the simplest. There is no motor and no wiring, and it never needs switching on. It suits a cloakroom or a utility, or a bathroom that already has a working extract fan somewhere else and just needs daylight with a little background air movement. As the main extract for a shower room with no window, it is unlikely to satisfy the benchmark on its own.

A fan in the ceiling ring keeps everything in one assembly, which makes it neat. The fan sits close to the room, so you will hear it, much as you hear an ordinary ceiling extract fan today. Because the fan pulls hardest near its inlet, it copes best with short, direct duct runs.

An inline fan sits in the loft, somewhere along the duct. Moving the motor away from the ceiling makes it noticeably quieter in the room, and inline fans are generally better at pushing air along a longer or bendier route. The cost is a slightly more involved installation: the fan needs a solid mounting, a power supply in the loft and access for later cleaning.

Which one is right depends on the room, the loft and whether you already have an extract that works. There is no single best kit, and it is sensible to be wary of any choice made from a brochure before someone has looked at the loft.

Keeping the daylight when you add the air

A vent ring takes up space around the diffuser and the duct takes up space in the loft, so the light side has to be planned with the air side from the start.

On the light side, the question is the same as for any bathroom tube: enough diameter for the room, as short and straight a run as the roof allows, and a dome placed where it sees the most sky. For a typical bathroom, a 250mm tube is the usual starting size, stepping up for a larger room or a long run; the sun tunnel diameter guide goes through that choice. Every bend and every extra metre of tube costs light, as sun tunnel length and bends explains, and a vent sleeve or a neighbouring duct should never force the light tube into an extra elbow it would not otherwise need.

Where the circle lands on the ceiling matters for both jobs. For light, the diffuser generally does most good over the basin and mirror, where you need to see your face clearly, or over the middle of the room if it is small. For air, extract works best close to the source of steam, over or near the shower or bath, and away from the door, so that replacement air sweeps across the room rather than short-circuiting straight from the door gap to the grille. In a narrow Cambridge terrace bathroom, those two positions can be a metre apart. Where they conflict, we will say which one we think should win and why, and sometimes the honest answer is a separate extract over the shower and a plain sun tunnel over the basin.

The sun tunnel diffusers guide covers the different finishes, and where to put a sun tunnel on the roof explains how the dome position on the slope affects the brightness below.

Section through a pitched roof and loft showing a sun tunnel: a dome and flashing on the tiles, a rigid reflective tube with an offset bend through the loft, and a ceiling diffuser spreading light into the hallway below.1234567
Fig. A sun tunnel taking daylight from the roof, through the loft, into a hallway with no window.
  1. Dome: a clear, UV-stable dome that catches daylight from a wide angle.
  2. Flashing: a flashing plate that sits into the tiles or slates, like a roof window flashing.
  3. Rigid reflective tube: a highly reflective lining bounces the light down its length. Rigid tube loses far less light than flexible.
  4. Adjustable bends step the tube around joists, purlins or tanks. Every bend and every metre costs some light, so the run is kept short and straight.
  5. Ceiling diffuser: a ring and a frosted lens that spread the light evenly and seal the ceiling.
  6. Light into the room: a hallway, landing or bathroom with no window gets real daylight.
  7. Loft insulation made good around the tube, which is often sleeved in the loft to limit condensation.

Condensation, insulation and the cold loft

Warm, wet bathroom air meeting a cold loft is the risk that a ventilation kit has to manage, and the answer is insulation around both the duct and the tube, and a sensible fall to the outlet.

A bathroom duct carries air at room temperature and close to saturation. In a Cambridge winter the loft above can be not much warmer than outside. If that duct is left bare, moisture condenses on its inside wall and runs back towards the ceiling, where it can drip from the grille or stain the plaster. The same applies to the light tube itself: its outer surface can reach dew point if the loft insulation is pulled away from it.

The practical precautions are well known:

  1. Use insulated duct, or wrap the duct fully, for its entire length through the cold loft.
  2. Keep the duct as short and direct as the route allows, with the fewest possible bends.
  3. Where the route allows, run the duct with a gentle fall towards the outlet so any moisture drains outwards rather than back into the room, or fit a condensation trap where a fall is impossible.
  4. Restore the loft insulation snugly around the light tube and any sleeve, so there is no cold ring around the ceiling.
  5. Terminate at a proper outlet, a roof vent tile, a ridge or soffit terminal, or the kit's own roof collar, never into the loft space.

That last point is worth stressing. Discharging bathroom air into the loft and hoping it disperses is a recipe for damp timbers and mould. Every duct we install ends outside. For more on the tube side, see can a sun tunnel go through loft insulation and do sun tunnels cause condensation.

Controls, switching and evening light

A fan needs a way to switch on and off, and the choice of control decides whether the room stays dry without anyone having to think about it.

The common options are straightforward. A fan wired to the bathroom light switch starts when you go in and, with a timer, runs on after you leave. A humidistat starts the fan when the air reaches a set humidity, whatever the light is doing, which suits a room where the daylight from the tube means nobody switches the light on in the morning. That is a real point with a sun tunnel: if the fan only runs with the light, and the light is no longer needed at 8am, the shower steam may never be extracted. A humidistat, a presence sensor or a separate switch closes that gap.

Many bathroom kits can also take an LED ring inside the diffuser, so one fitting gives daylight by day, electric light at night and extract whenever it is needed. Sun tunnels with LED lights covers how those rings work. Electrical fittings in a bathroom must be suitable for their zone near the bath or shower, and we plan the diffuser position with that in mind.

Roof, planning and the outlet you will see from the street

A ventilation kit can add a second thing on the roof, a vent terminal, so it is worth thinking about how the outside will look as well as the inside.

Where the kit vents through its own collar around the dome, there is only one penetration. Where it uses a separate duct, the outlet might be a vent tile on the same slope, a ridge terminal or a soffit vent at the eaves. On a slate roof in Romsey, a discreet slate vent on the rear slope is barely noticeable; on a thatched or plain-tiled village cottage, the outlet position deserves more care. A soffit outlet avoids any roof penetration at all, but it only works if the eaves are close enough to reach without a long, bendy duct.

Sun tunnels on a house generally fall within permitted development, provided they do not project more than 150mm from the roof plane and the other limits are met. In a conservation area, on a flat or maisonette, or on a listed building, the position can be different, and an Article 4 direction can remove permitted development rights altogether. Greater Cambridge Shared Planning covers Cambridge City and South Cambridgeshire, and it is worth checking constraints on your address before committing. See do sun tunnels need planning permission and sun tunnels in a conservation area for more.

Replacing an old fan with a combined kit

Many internal bathrooms already have an extract fan, and a combined kit can replace it so the ceiling ends up with one fitting instead of two.

Before removing a working fan, it helps to know where its duct goes and whether it actually reaches outside. In older conversions the answer is not always reassuring. If the existing duct is sound, insulated and correctly terminated, it can sometimes be kept and the new fan connected to it, with the old ceiling hole made good. If it is uninsulated, crushed or discharging into the loft, it is better replaced along with the new kit. Either way, replacement work should leave the room ventilated at least as well as it was before, and Building Control may want to see that the new arrangement meets the current benchmark.

Sometimes the right answer is to keep the fan exactly where it is, over the shower, and add a plain sun tunnel over the basin. That gives the best position for each job and avoids compromising either. The light survey is where we look at the loft, trace the existing duct and decide which route gives the better room.

What happens on the day

A combined kit is fitted in much the same way as a plain sun tunnel, with extra time for the duct route, the fan and the electrics.

The roof opening and dome come first, then the tube is run through the loft to the ceiling, followed by the vent ring or sleeve, the duct and the outlet, the fan if there is one, insulation around everything in the loft, and finally the diffuser and ring from below. An electrician wires the fan and any LED ring and provides the electrical paperwork. The ceiling is made good around the fitting and the room is left clean. For a sense of how long a typical tube takes, see how long sun tunnel installation takes. Every quote comes with a written light plan showing the tube size, dome position, diffuser position and extract route, and the reason for each, and the work is covered by our 10-year workmanship guarantee.

Questions people ask

Can a sun tunnel on its own ventilate a bathroom?

No. A standard sun tunnel is sealed so no air passes through it. For ventilation you need either a kit designed to add an extract path or a separate extract fan.

Will a passive kit meet Building Regulations in a windowless shower room?

It may not. The usual benchmark in Approved Document F for an intermittent bathroom fan is 15 l/s, and a passive vent may not reliably reach it. Building Control decides what your room needs, and a powered extract is the safer plan where there is no openable window.

Does adding ventilation reduce the light?

Only slightly, if planned well. The vent ring sits around the diffuser rather than in front of it. The bigger risk is a duct that forces the tube into an extra bend, which is why the two routes are planned together.

Can I add a ventilation kit to a sun tunnel I already have?

Sometimes, depending on the make and model. Some ranges offer a retrofit ring; others do not, in which case a separate extract or a replacement unit is the practical route. Book a light survey and we will look at what you have.

Book a light survey

Tell us about the room

  • No obligation
  • Light plan in writing
  • 10-year guarantee
Book a survey Call