Question

Do sun tunnels need building regulations?

The short answer

Sometimes. A sun tunnel always has to meet the Building Regulations, but whether the job must be notified to Building Control depends on the work itself: whether a rafter or joist is cut, whether the tube passes through a ceiling that acts as a fire separation, and how the roof and loft insulation are made good. Building Control decides, and we handle the notification when the work is notifiable.

Why there is no single yes or no

The Building Regulations apply to building work, not to products, so the question is less "is a sun tunnel notifiable?" and more "is this particular installation notifiable?".

A tubular skylight is a small thing: a dome on the roof, a reflective tube through the loft and a diffuser in the ceiling, as our guide to how sun tunnels work explains. On many roofs a 250mm or 350mm tube slips between the rafters and between the ceiling joists without touching either, and the only change to the building is a neat hole in the roof covering and one in the plasterboard. On other roofs the same kit means trimming a rafter, cutting through a fire-resisting ceiling or rebuilding a section of a flat roof deck.

Those are different jobs in the eyes of the regulations, even though the product in the box is identical. That is why we will not give a blanket answer here, and why nobody should. What we can do is set out the parts of the regulations that come into play, so you can see which way your own job is likely to fall before the survey.

The parts of the regulations a sun tunnel can touch

Four parts of the Building Regulations for England are the ones that usually matter for a tubular skylight, and each is triggered by a different feature of the job.

PartWhat it coversWhen it matters
A, structureRafters, joists, loadsA rafter or joist is cut or trimmed
B, fireFire separation, spreadThe tube passes a fire-resisting ceiling or sits near a party wall
L, energyHeat loss through the roofRoof or ceiling insulation is disturbed or renewed
C, moistureCondensation, weatherThe tube runs through a cold loft

If the job also brings in an LED kit or an extract fan, Part P (electrical safety) and Part F (ventilation) can join the list. Our guides to sun tunnels with LED lights and sun tunnel ventilation kits cover those add-ons. Electrical work in a bathroom, for example, is often notifiable in its own right, usually by the electrician who does it.

Decision path for a rooflight project: whether the roof structure is altered leads to Building Control or a competent person scheme, and whether the house is listed or in a conservation area leads to asking the council or usually permitted development.YNYN≤150mm1234567
Fig. Two separate questions for most rooflight projects. A general guide, not advice for your house: check with the council.
  1. Is the roof structure altered? For example rafters or joists cut and trimmed to make a new or bigger opening.
  2. Yes: usually a Building Regulations application to Building Control (the council or a registered building control approver) before work starts.
  3. No, for example a like-for-like replacement: usually self-certified by an installer in a competent person scheme, or notified to Building Control.
  4. Is it a listed building or in a conservation area, or a flat? These can change what is allowed.
  5. Yes: check with the council first. Listed building consent or planning permission may be needed.
  6. No: rooflights on a house are usually permitted development if they stand no more than 150mm proud of the roof slope, sit no higher than the ridge, and any on a side slope are obscure-glazed and fixed below 1.7m. Lanterns often stand higher, so check.
  7. Both answered: the work goes ahead. Keep the certificates, since a buyer’s solicitor will ask for them.

Cutting timbers: the structural question

If the tube fits between the existing rafters and joists, the roof structure is left as it was; the moment a timber has to be cut, the job becomes a structural alteration.

Rafters in a typical Cambridge terrace or 1930s semi sit at roughly 400mm to 600mm centres, so the clear gap between them varies from house to house. A 250mm tube for a bathroom will fit most gaps comfortably. A 350mm or larger tube, the size often chosen for a dark landing, may not, and on a trussed roof in a newer home at Trumpington or Cambourne the trusses must not be cut at all without an engineer's design. Our diameter guide shows how the tube size follows the room, and the survey tells us whether that size fits the timbers you have.

Where a rafter does need trimming, the load it carried has to be picked up by new timbers either side. That is work Building Control will want to see, and it is one of the clearest signs a job is notifiable.

Fire separation where the tube passes through

A ceiling is sometimes more than a ceiling: in some homes it is part of the fire protection, and a hole cut through it has to keep that protection intact.

Examples include the ceiling of an integral garage below a bedroom, the ceiling over the protected stair in a converted loft, and the ceiling between a top floor flat and the roof void shared with neighbours. If you live in a flat, the lease also matters, which our answer on fitting a sun tunnel in a top floor flat covers. Close to a party wall, the roof itself plays a part in stopping fire spreading to the house next door, so the dome position needs care there too. In these cases the detail around the tube, how the ceiling is sealed and what the diffuser assembly is made of, is something Building Control may ask to approve.

Thermal performance and condensation

A tube crossing a cold loft is a small channel of warm room air meeting cold outside air, so the insulation around it matters for heat loss and for moisture.

Part L sets standards for the thermal performance of roofs and ceilings when they are altered, and the way the tube passes through your loft insulation is where that shows. Leaving a gap in 270mm of mineral wool around a tube is both a heat leak and an invitation for warm, damp air to condense on the cold tube wall. Our answers on running a sun tunnel through loft insulation and condensation in sun tunnels set out the details. On a flat roof, where the dome sits on an upstand, the warm deck and its insulation have to be made good around the opening as well.

How the notification works when it is needed

When Building Control agrees that a job is notifiable, it goes through either the council's Building Control service or a registered building control approver, and we take care of that for you.

For a small job this is usually a building notice or a short application before work starts, followed by an inspection or evidence of the key stages and a completion certificate at the end. That certificate is worth keeping with the house deeds: a buyer's solicitor may ask about any alteration to the roof, and a completion certificate answers the question cleanly. Building Regulations are separate from planning permission, which is a different test about how the dome looks from outside; see do sun tunnels need planning permission? for that side. Where a job is not notifiable, we still install to current Building Regulations, and the written light plan that comes with your quote records the position, size and route of the tube.

Questions people also ask

Can I just fit a sun tunnel myself without telling anyone?

The regulations apply whoever does the work, and if a job is notifiable the homeowner is ultimately responsible for it being notified. If you are unsure, ask Building Control before you start. Our sun tunnel installation service includes that question as part of the survey.

Does replacing an old sun tunnel need Building Control?

A like-for-like replacement in the same opening, with no timbers cut and the insulation restored, is a lighter job than a new installation. Whether it needs notifying still depends on what the work involves, so we check it at the survey rather than assume.

Is a sun tunnel treated like a rooflight under the regulations?

It raises some of the same questions, because it is an opening in the roof covering, but it is a much smaller one with no large glazed area. The thermal and fire checks are similar in kind, just on a smaller scale.

Who decides in the end?

Building Control does. We give you our reading of the job at the survey, and where there is any doubt we ask them before the roof is opened. Book a light survey and we will look at your roof, loft and ceiling together.

Book a light survey