What a roof window combination is
A roof window combination is two or more roof windows fitted close together in the same slope, sealed by one purpose-made flashing so they read as a single glazed area. Stacked, side by side or paired with a vertical window below, a combination turns part of a pitched roof into something closer to a glazed wall.
A single roof window is sized to fit the gap between two rafters, or to fit a trimmed opening one rafter wider. That limits it to a strip of glass perhaps 55 to 134 cm wide, set at one height on the slope. A combination breaks that limit without asking one sash to do everything. Each unit stays a normal, standard-sized window with its own opening, glass and blind. The flashing kit that joins them is the part that makes it a combination: instead of every window having its own separate collar of aluminium, the kit runs continuously around the group and fills the narrow strip between frames.
People searching for this call it all sorts of things: a pitched roof skylight combination, a twin roof window, a glazed gable in the slope, a "wall of Veluxes". The trade name varies by maker, but the idea is the same. Several ordinary windows, arranged on a grid, finished as one piece of roof.
There are three basic arrangements, and they can be mixed:
- Side by side: two or three windows across the slope at the same height, separated by a rafter or a slim strip of roof.
- Stacked: one window directly above another in the same bay, the upper one usually fixed and the lower one opening.
- With a vertical element: a roof window in the slope with a fixed or opening vertical window in the wall below it, where the room has a wall rising above floor level before the roof begins.
Our main page on roof window installation in Cambridge covers single windows and the wider service. This guide is about the point where one window stops being enough, and what changes, inside the room and in the roof, when several are grouped.
Why group roof windows at all
A combination is worth the extra work when the room needs a wider spread of light, a view from both sitting and standing height, or a single glazed feature that suits the space. It is not automatically brighter per square metre than separate windows, and on the wrong slope it adds heat faster than it adds comfort.
Spread is the first reason. A single roof window throws a defined shape of daylight onto the floor and the opposite wall, and on a sunny day that sun patch moves across the room as the hours pass. Two windows side by side widen the patch and soften the dark bands either side of it, which matters in a long loft room where the useful part of the floor runs along the slope. The answer on how far apart roof windows should be sets out when spacing windows along the room lights it better than grouping them, and it is worth reading before settling on a combination.
The view is the second. A roof window gives you sky from a chair and a view out from a standing position, depending on how high it sits. A stacked pair gives you both at once: the lower window can have a sill low enough for someone seated to see the gardens below, while the upper window carries the glass up the slope to catch the sky. In a Cambridge terrace loft looking across the back gardens of Romsey or Chesterton, that lower view is what makes the room feel like part of the street rather than an attic.
The third reason is the room itself. A double-height space, a vaulted living room, a studio or the end wall of a long loft can take a composed group of glass in a way a small bedroom cannot. Here the combination is closer to architecture than to lighting: it sets the character of the room.
What a combination does not do is solve a room that is lit from the wrong side. A dark north-west corner stays dark if the group of windows sits on the opposite slope. Position still comes first, and our guide to positioning a roof window in a room is the place to start before thinking about quantity.

Side by side, stacked and vertical: the arrangements compared
Each arrangement changes the light in a different direction: side by side widens it, stacked lengthens it up the slope, and a vertical element brings it down to the floor. The table sets them against each other before the detail.
| Arrangement | Light it gives | Suits | Watch for |
|---|---|---|---|
| Side by side | Wider sun patch, even across the room | Long lofts, bedrooms, offices | Rafter left or trimmed between |
| Stacked | Sky high up, view low down | Tall slopes, vaulted rooms | Height of the upper sash |
| Vertical element | Light to floor level, view out | Rooms with a wall below the eaves | Eaves structure, guarding |
| Grid (2 by 2 or more) | A glazed wall in the slope | Studios, double-height spaces | Heat, glare, structure |
Side by side
Two windows across the slope can sit either side of a rafter that is left in place, or in a wider opening where the rafter between them is cut and the load carried by trimmers. Keeping the rafter is simpler structurally, and the combination flashing kit is made for that gap. The frames then sit a rafter width apart, with a timber lining between them inside. Cutting the rafter lets the windows sit closer, but it turns the job into a structural alteration, covered below. A row of three on a long slope reads well from inside and outside, provided the heads and sills line through.
Stacked
One window above another in the same bay stretches the glass up the slope. The upper unit is usually fixed, because its handle would be out of reach, and the lower one opens. The gap between them is a short strip of roof carried on a horizontal trimmer, and the flashing kit covers it in one piece. Inside, the horizontal lining between the two frames can be kept slim so the pair looks like one tall opening.
Vertical element
Where a room has a vertical external wall rising above the floor before the roof starts, a fixed or opening window can go in that wall directly below the roof window. The two frames meet at the eaves line and are finished as one. From inside, the glass then runs from knee height up into the slope, and you can stand at it and look straight out rather than up. This is the arrangement that most changes a room, and it is also the one with the most structure to think about.
- Rafter beside the opening, with insulation between the rafters.
- Trimmers across the rafters above and below the window, set back so they sit clear of the splayed lining.
- Battens and breathable underlay, the underlay turned up around the frame.
- Slates or tiles, cut and re-laid around the window.
- Flashing kit: an apron dressed over the slates below the window, and a head flashing tucked under the slates above.
- Insulation collar packed around the frame so the cold bridge at the opening is closed.
- Vapour control layer lapped to the frame with a collar, keeping warm, moist room air out of the roof.
- Lining: level at the head and plumb at the sill, so the opening widens into the room and throws more light down.
- Roof window: frame, sash and a sealed glazed unit, sitting a little above the slates in a standard fitting.
Where the light lands with a glazed slope
More glass in the slope means the orientation of that slope decides even more about how the room feels. A combination facing south over a Cambridge garden will need solar control glass and external shading; the same group facing north gives steady, cool light that suits a studio or study without much further thought.
Cambridge is flat, and flat land shades very little. A roof slope here sees the whole sky and, on a clear day, the sun from the moment it rises over the Fens to the moment it sets. That makes the arithmetic of a combination straightforward. Double the glass on a south slope and you roughly double the direct sun entering the room on a clear afternoon, along with the heat that sun carries. On a north slope you double the soft, even skylight instead, which is almost always welcome.
A side by side pair on a south-facing rear slope throws a broad rectangle of sun onto the floor in winter, when the sun is low and the light is precious. In June the same pair throws a smaller, brighter shape much closer to the base of the slope, and warms every surface it touches. East slopes give a strong, low morning sun that can reach deep into the room, pleasant in a bedroom that is empty by nine. West slopes do the same in the late afternoon and evening, the time a living space or a loft office is most likely to be in use, and they are the slopes where glare across a screen causes the most trouble.
The vertical element behaves differently from the glass above it. Vertical glass takes in less of the high summer sun and more of the low winter sun than glass in the slope, so a roof window with a vertical window below it spreads its gains more evenly through the year than a stacked pair of roof windows of the same total area. It also puts light right down onto the floor near the wall, where a roof window alone leaves a dim strip.
Glass choice follows from the slope. Solar control coatings reduce the share of solar energy that gets through, laminated inner panes make the overhead glass safe if it breaks, and triple glazing trims heat loss on a cold north slope. Each window in a combination can have its own specification, which is useful: a fixed upper unit on a south slope might carry a stronger solar control coating than the opening unit below it. The guide to roof window glazing options goes through the panes room by room. Our wider approach to orientation, sun path and glare is on how we plan the light.
The structure behind a group of windows
A combination that fits between existing rafters, with a rafter left between each window, is a light structural job. Once rafters are cut to make a wider opening or to take a vertical element, the roof needs trimmers sized for the load, and on a larger group that normally means a structural engineer's calculation.
Rafters in older Cambridge houses are commonly set somewhere between about 350 and 450 mm apart, and not always evenly. Newer homes built with trussed rafters are typically at 600 mm centres, and trusses must not be cut without a design from the truss maker or an engineer. The spacing decides which window widths fit without cutting and how many bays a combination has to span. A survey measures the actual spacing, not the drawing, because in a Victorian roof the two rarely match.
When a rafter is removed, the load it carried has to go somewhere. Trimmers across the head and foot of the opening carry it to doubled rafters either side, and those in turn carry it down to the wall plate and up to the ridge or purlin. A stacked pair needs an extra horizontal trimmer between the two windows. A grid of four needs the lot. Our guide to trimming rafters for a roof window explains how that works and when it becomes an engineer's job.
The vertical element adds the eaves to the picture. To put glass in the wall below the roof window, the timber at the eaves line, and sometimes the wall plate itself, has to be rearranged so the roof still bears properly on the wall. In a traditional cut roof with a knee wall, that can be straightforward. In a roof where the rafters sit directly on the external wall at floor level, there is no vertical wall for the element to go in without raising part of the roof, which is a different project.
Purlins matter too. Many terrace and 1930s roofs have a purlin running along the slope roughly halfway up, supporting the rafters. A stacked combination tall enough to cross the purlin line cannot simply cut through it. The group may need to be split either side of the purlin, or the purlin supported another way, and that is decided with the structure in front of you, not from a catalogue.
Flashings, pitch and the roof finish
Combination flashing kits are made for fixed gaps between frames, so the layout of the group is settled by the kit as much as by the room. They are made for particular roof finishes and pitch ranges, and the roof has to fall within both.
Each maker publishes combination kits for side by side, stacked and grid arrangements, in a range of standard gaps between frames. The gap inside the room is set by the same measurement, so the layout of the windows, the spacing of the rafters and the kit all have to agree before anything is ordered. A pair that looks right on a drawing but needs a gap no kit is made for has to be redrawn.
The roof covering matters in the usual way. Plain clay tiles, concrete interlocking tiles, pantiles and natural slate each take a different flashing profile, and on a combination the flashing runs further, so getting that profile right matters more. Our guide to roof window flashings sets out how the kits differ by covering. Slate on the older terraces around Mill Road and plain tiles on village cottages around Grantchester both take combinations well when the right kit is used. Recessed installation, which sets the frames lower in the roof so they sit closer to flush, is available in combination form for many sizes and is worth asking about on a visible slope.
Pitch limits apply to every window in the group, and a vertical element has its own limits for the roof angle it can be paired with. On a shallow roof, a stacked combination may be ruled out even where a single window is fine. Each maker publishes the pitch range for every window and kit, and the survey checks the real pitch against it.
Planning and Building Regulations
A combination of roof windows is treated in planning terms much like any roof window: often permitted development on a house, subject to limits and local restrictions. Under Building Regulations, new roof windows are normally notifiable, and a combination that cuts rafters or alters the eaves brings structure into the notification as well.
Under Class C of the permitted development rules for houses, roof windows can generally be added without a planning application if they project no more than 150 mm beyond the roof plane, sit no higher than the highest part of the roof, and, if on a side-facing slope, are obscure glazed and non-opening unless more than 1.7 m above the floor. Those rights do not apply to flats and maisonettes, and they can be removed by an Article 4 direction. A listed building needs listed building consent for any change. In Cambridge, planning is run by Greater Cambridge Shared Planning for both the city and South Cambridgeshire, and the council's constraints map shows whether a property sits in a conservation area or under an Article 4 direction.
In a conservation area, a large glazed group on a front slope facing the street is much harder to justify than the same group on a rear slope. The usual accepted pattern on the terraces of Romsey and Petersfield puts a dormer or larger glazing at the back and keeps the front to smaller, flush rooflights. A vertical element, because it alters the wall and eaves, may take a project outside permitted development even on a rear slope, and should be checked before design goes further.
For Building Regulations, the points a combination raises are structure (any trimmed rafters, purlins or eaves changes), thermal performance, where rooflights must meet a limiting U-value of 2.2 W/m²K, safety glazing and guarding where glass sits low, and escape if the room relies on a roof window for it. A vertical element with its sill close to the floor needs safety glass and may need guarding. Where the work is notifiable, we handle the Building Control notification. The answer on whether roof windows need building regulations covers what the inspector checks.
Choosing a combination for your room
Start with how the room is used and which way the slope faces, then decide the arrangement, and only then pick sizes. A combination chosen the other way round tends to give a striking roof and an uncomfortable room.
A few questions sort out most rooms. Where do people sit, stand and work, and at what times of day? A loft office used in the afternoon on a west slope needs a different group from a guest bedroom on the same slope. Is there a view worth bringing down to eye level? If so, a stacked pair or a vertical element earns its place; if the view is a neighbour's wall, a side by side pair higher up gives the light without the outlook. How tall is the slope inside the room? A short slope under a low ridge has room for one row, not two. And what sits below the windows? A bed, a desk or a stair each set their own limits on sill height and opening type.
The opening types within a group can be mixed. A fixed upper window above a top hung lower one gives the lower sash a full view when open and keeps the upper one simple. A pair of centre pivots side by side works where furniture sits close beneath. Where one window needs to serve as an escape route, that unit has to meet the escape rules on its own, whatever the rest of the group does. The guide to types of roof window compares the openings in detail.
Size down before you size up. Two smaller windows well placed will usually light a room better, and with less heat, than one oversized group over the wrong part of the floor. For a vaulted room, the guide to roof windows in vaulted ceilings covers setting the height of glass when the ceiling runs to the ridge.
Cost follows the number of units, the flashing kit, the structure and the finish inside, rather than the glass alone. The page on skylight and rooflight costs explains what moves the figure. Every quote we give comes with a written light plan setting out the arrangement, sizes, glass and shading we recommend for your slope, and why. If you are weighing up a combination, book a light survey and we will show you where the light will land before the roof is opened.
Questions people ask
Can I add a second roof window next to an existing one?
Often, yes, but it may not be possible to join them as a true combination. The existing window's size, age and flashing were chosen for a single unit. To seal the pair under one combination kit, the old window generally has to be replaced so both frames match and sit at the right gap. Two separate windows with their own flashings are simpler where the spacing allows.
Do all windows in a combination have to be the same size?
Side by side windows need matching heights so their heads and sills line through, and stacked windows need matching widths. Combination flashing kits are made for matching frame sizes in each direction, so mixing sizes in the same row or column is not usually an option.
Is a combination harder to keep weathertight than a single window?
Not when it is fitted with the correct combination flashing kit for the roof covering and pitch. The kit is designed to carry water around and between the frames as one unit. The work is in setting out the frames accurately so the kit fits as intended.
Can a combination include an electric window?
Yes. Any window in the group can be electric or solar-powered, which is useful for an upper unit that would otherwise be fixed because its handle is out of reach. A rain sensor closes it automatically when the weather turns.




