Question

Are roof lanterns energy efficient?

The short answer

A modern roof lantern is energy efficient for glazing, but it will never match the insulated roof it sits in. A good thermally broken lantern with low-E double or triple glazing loses several times more heat per square metre than a well-insulated flat roof. It pays some of that back in daylight and winter sun, and the right size and glass keep the balance sensible.

The number that matters: the whole-lantern U-value

Judge a lantern on the U-value of the complete unit, frame and glass together, measured the way Building Regulations now measure it: in the horizontal plane.

A U-value tells you how many watts pass through one square metre of the element for each degree of difference between inside and outside, so lower is better. Brochures often lead with the centre-pane figure, which describes only the middle of the glass, well away from the frame. A low-E, argon-filled double glazed unit might be quoted at around 1.0 to 1.2 W/m²K at the centre. The frame, the glazing bars, the ridge and the spacers around each pane all lose heat faster than that, so the whole-unit figure for the same lantern is higher.

The second catch is how the test is set up. Glass laid flat or at a shallow pitch loses more heat than the same glass standing upright, because warm air rising against the underside of the pane keeps it moving. Older data sheets gave rooflight U-values in the vertical plane, which flatters them. The 2021 edition of Approved Document L assesses rooflights in the horizontal plane and sets a limiting value of 2.2 W/m²K for rooflights in existing homes, whether new or replacement. A quality lantern should sit comfortably below that. Ask for the whole-unit, horizontal-plane figure, and compare like with like.

Where the heat actually leaves: frame, bars and glass

Most of the difference between an efficient lantern and a poor one lies in the frame, because the glass in most current lanterns is broadly similar.

Aluminium conducts heat very well, so an aluminium lantern needs a thermal break: a strip of low-conductivity material, usually polyamide, that splits each profile into an inner and an outer half. Without it, the inside face of every bar tracks the outdoor temperature, and on a frosty night you get a grid of cold lines across the ceiling. With it, the inner face stays much closer to room temperature. uPVC is a poorer conductor to begin with, and its chambered profiles do a similar job, but the bars are thicker for the same span. We set out the full trade-off in our guide to aluminium vs uPVC roof lanterns.

Then come the choices that move the figure most:

  • Glass build-up. Low-E coated double glazing with argon is the usual base. Triple glazing lowers the U-value further, at the cost of weight and a little light. Our roof lantern glass options guide compares them.
  • Warm-edge spacers between the panes, instead of aluminium spacer bars, cut the cold band around each pane edge.
  • Bar count. Fewer, wider panes mean less frame per square metre, and frame is the weaker part.
  • The upstand. The kerb the lantern sits on is part of the thermal envelope. An insulated timber or factory-made upstand keeps a cold bridge from forming at the perimeter, which is where condensation tends to show first.

How a lantern compares with the roof it replaces

Every square metre of lantern replaces a square metre of insulated roof, and on heat loss alone the roof wins by a wide margin.

A new or renewed flat roof on an extension is insulated to a very low U-value, typically somewhere around 0.15 to 0.18 W/m²K under current guidance. Even an excellent lantern is several times higher than that. The worked example below uses a 3m by 1.5m lantern on a still winter evening, with the room at 20°C and the air outside at 0°C. The figures are rounded and illustrative, not a test of any product.

Element over 4.5m²U-value (around)Heat lost
Insulated flat roof0.15 W/m²Kabout 14W
Triple glazed lantern1.0 W/m²Kabout 90W
Good double glazed lantern1.4 W/m²Kabout 125W
Older lantern, poor frame2.8 W/m²Kabout 250W

The real glazed area of a lantern is a little larger than its plan area, because the hips and slopes rise, so the true figures are slightly higher again. Set against a whole house, 100W or so is modest: similar to an old incandescent bulb left on. Swapping a tired lantern for a modern one roughly halves that loss, which is why replacement is often the easiest energy upgrade in an extension.

What a lantern gives back: daylight and winter sun

A U-value only counts heat going out. A lantern also lets energy in, as daylight that replaces electric lighting and as sunshine that warms the room.

Overhead glass sees the whole sky, so a lantern lights a deep extension far better than a wall window of similar size. In a Romsey or Mill Road terrace with a long, dark rear room, that can be the difference between lights on all day and lights off until dusk from spring to autumn. Modern LED lighting uses little power, so the saving is real but small; the bigger gain is the room itself.

Solar gain is the other credit. On a bright February afternoon, low sun through a lantern adds free heat that the heating system does not have to supply. Cambridge helps here: flat land and a wide, open sky mean little shading from hills. The same openness is what makes summer the harder season, so the glass has to be chosen for July as well as January. That balance, and the solar control options that manage it, is covered in our guide to controlling heat and glare under a roof lantern. It is also the core of how we plan the light before a roof is cut.

Building Regulations and the glazing allowance

Building Regulations set both a performance floor for the lantern and, for extensions, a limit on how much glazing you can add before the design has to prove itself another way.

Fitting a new lantern is normally notifiable work, and we handle the Building Control notification where it is. Alongside the 2.2 W/m²K limit for the unit, Approved Document L generally expects the total area of windows, roof windows and doors in an extension to stay within about 25% of the extension's floor area, plus the area of any openings the extension has closed off in the existing house. Go beyond that and the designer usually has to show, by calculation, that the extra heat loss is made up elsewhere, for instance with better insulation or better-performing glazing. It is a good reason to settle the lantern size alongside the rest of the glazing rather than on its own; our roof lantern size guide sets out how. Your architect or Building Control body will confirm how the rules apply to your drawings.

Questions people also ask

Is triple glazing worth it on a roof lantern?

It lowers heat loss and keeps the inner glass warmer, which helps comfort under a large lantern. It also adds weight, so the frame and the roof lantern installation have to be designed for it, and it trims light transmission slightly. For a big lantern over a room you sit in on winter evenings, it is well worth pricing.

Does an energy efficient lantern stop the room overheating?

No. A low U-value slows heat moving through the glass in either direction, but it does little to stop direct sunshine entering. Summer heat is governed by the g-value, the share of solar energy the glass lets through. Our answer on whether roof lanterns make a room hot covers the fixes.

Will replacing an old lantern cut my heating bills?

It will reduce heat loss through that part of the roof, often by around half or more if the old unit has single glazing or an unbroken frame. The saving on the whole bill depends on the house, but the room usually feels noticeably warmer. See do roof lanterns make a room cold for why.

Are glass lanterns more efficient than polycarbonate ones?

Generally, yes. Thin polycarbonate sheet has a much higher U-value than modern sealed glass units and loses clarity over time. General market prices for both are on our costs page, and a light survey confirms which unit suits the room.

Book a light survey

Tell us about the room

  • No obligation
  • Light plan in writing
  • 10-year guarantee
Book a survey Call