Where the warmth goes on a January night
A rooflight loses heat in winter through five routes at once: the glass, the edge of the sealed unit, the frame, the upstand or lining it sits on, and any air that slips past the joints. The glass is the largest route by area, but the other four decide whether the unit feels cold.
Picture a flat rooflight over a kitchen extension in Chesterton at eleven o'clock on a still, clear night in January. The room is at 20°C, the air above the roof is just below freezing and the sky is cloudless. Heat is leaving the room through the middle of the glass by conduction and radiation. At the perimeter it is running sideways along the spacer bar that separates the panes. It is flowing through the metal or plastic of the frame, down through the timber kerb that lifts the unit clear of the roof, and out through any gap where the roof insulation stops short of the opening. If the unit opens, or if the seal between frame and kerb was never made airtight, warm air is also being pushed out and cold air drawn in.
A datasheet collapses most of that into a single number, the whole-unit U-value, which our guide to rooflight U-values explains in detail. What that number does not include is the upstand, the junction with the roof and the air leakage around the installation. Those three belong to the fitting rather than the product, and they are the reason two skylights with identical U-values can behave very differently in the same street.
This guide takes each route in turn, says roughly how much it matters, and ends with the order of priorities we work through when we specify or replace a unit. The wider choices, including glass, orientation and summer comfort, sit on the energy efficient rooflights page.
The glass: the biggest surface, facing the coldest sky
Glass is where most of a rooflight's winter heat loss happens simply because it is most of the area. Lying close to flat makes it lose more than the same glass would in a wall, for two separate reasons.
The first is convection inside the sealed unit. In a vertical double-glazed window the gas in the cavity forms a slow circulating loop, which carries a modest amount of heat across. Tilt the unit towards horizontal and the warm inner pane sits underneath the cold outer pane. Warm gas rises, meets the cold pane, sinks, and the loop becomes a more efficient heat pump from room to sky. This is why Part L now asks for rooflight U-values to be declared in the horizontal position: the same glass unit can read noticeably worse lying flat than standing upright.
The second is the sky itself. A wall window looks at the street, the house opposite and a band of sky. A flat skylight looks at nothing but sky. On a clear, dry night the effective temperature of the sky can sit twenty degrees or more below the air temperature, so the outer pane radiates heat upwards into what is, in effect, a much colder room than the thermometer suggests. That is why a rooflight is often the first surface on a house to frost over after a clear night on the Fen edge, and why frost on the outside of the glass is a good sign: it means the outer pane is cold because very little room heat is reaching it.
What controls this route is the glass build-up. A low-emissivity coating on one of the cavity faces cuts the radiant exchange between the panes. Argon in the cavity, instead of air, slows the conduction and convection. A third pane adds a second cavity. The low-E coatings and argon fill guide covers how those work inside the unit, and double versus triple glazing weighs the extra pane against its weight and light cost.
One practical point: the glass figure you see advertised, the centre-pane Ug, is measured away from the edges. It will always be lower than the whole-unit figure. For a small rooflight the gap between the two is large, because the edges make up a bigger share of the total; for a big lantern panel it narrows.

The edge of the sealed unit
Around the perimeter of every sealed glass unit is a spacer bar holding the panes apart, and in winter it is a narrow bridge carrying heat straight past the insulating cavity. On a small skylight it matters far more than its width suggests.
Traditional spacers are hollow aluminium, which conducts heat very well. The result is a cold strip around the inside edge of the glass, usually 50 to 70mm wide, that runs several degrees below the centre of the pane. Engineers describe this edge loss as a linear figure, in watts per metre of perimeter per degree, because it depends on the length of edge rather than the area of glass.
That is what makes it significant for rooflights. A 600mm by 600mm unit has 2.4 metres of edge wrapped around only 0.36 square metres of glass. Double the dimensions and the area quadruples while the edge only doubles. Small skylights, the kind used over landings and bathrooms in a Romsey terrace, therefore lose a far larger share of their heat through the edge than a large glazed panel does.
Warm edge spacers, made from stainless steel, structural foam or composite, reduce the edge loss substantially and lift the temperature of that inner strip. The benefit you notice is less about the heating bill and more about the edge of the glass staying dry on a cold morning. Our answer on what a warm edge spacer is goes further, and the link between cold edges and moisture is picked up in the rooflight condensation guide.
The frame
The frame is a thinner route than the glass but a denser one: a solid path of material from the warm side to the cold side. How much it matters depends on what it is made of and whether that path is interrupted.
Unbroken aluminium is the weakest case. Aluminium conducts heat many hundreds of times better than timber or uPVC, so an aluminium frame without a break is effectively a cold rail connecting the room to the outside. You can feel it with the back of a hand on a frosty morning, and it is often where a line of condensation forms first. Older aluminium kerb-mounted domes and early lantern systems fall into this group.
A thermally broken aluminium frame is split into inner and outer sections joined by a low-conductivity insert, usually glass-reinforced polyamide. The metal still looks continuous from inside, but heat has to cross the insulating strip to escape. Well-designed breaks bring a modern aluminium frame close to the performance of uPVC or timber while keeping the slim sightlines people choose aluminium for. Our guide to thermally broken rooflight frames covers the construction.
uPVC and timber frames conduct poorly by nature, which helps, but they are bulkier, and on a pitched roof window the frame is also where the roof insulation has to meet the product. Frameless units change the picture again: the glass sits directly on the kerb, so the frame route almost disappears and the edge of the glass and the kerb beneath it take over its role.
The upstand and kerb: the part no datasheet shows
A flat rooflight sits on an upstand at least 150mm above the finished roof, and that upstand is a small wall exposed to the weather on its outside face. If it is built as bare timber, it can lose as much heat per metre as a poor frame.
- Joists, with doubled trimmers either side of the opening to carry the loads of the cut joists around it.
- Deck (usually 18mm ply or OSB) with a vapour control layer laid on it.
- Insulation boards above the deck (a warm roof), often tapered to give the roof its falls.
- Waterproof membrane dressed up the upstand and over its top, so the joint is lapped, not sealed.
- Upstand, or kerb: insulated timber, finishing at least 150mm above the finished roof surface to keep standing water and splash off the joint.
- Rooflight unit fixed over the kerb, its frame skirt shedding water outside the membrane turn-up.
- Plastered reveal lining the opening from the ceiling up to the frame, finished white to bounce the light down.
- Roof falls to an outlet: designed at about 1:40 so the finished roof never falls less than 1:80.
On most flat roofs in Cambridge extensions the upstand is a site-built timber kerb, framed from structural timber, clad in the roof membrane and capped by the rooflight. Timber is a reasonable insulator compared with metal, but a 47mm thick kerb has nowhere near the resistance of the 120mm to 150mm of rigid insulation in the roof deck around it. Heat takes the easy route: out of the room, up the inside face of the kerb, across the timber and into the cold membrane on the outside.
A well-built kerb is wrapped in insulation on its outer face before the membrane goes over, and the roof insulation is carried right up to it with no gap at the base. Some manufacturers supply insulated factory upstands, typically uPVC or GRP with insulation built in, which take the site-built kerb out of the question. Either way, the inside face of the opening is lined and finished so that no bare timber is left open to the room with cold behind it.
On a pitched roof the equivalent is the lining around a roof window, running from the frame down to the ceiling. The frame sits between the rafters, and the roof insulation has to be brought tight up to it on all four sides. Manufacturers make insulating collars that fit around the frame for this reason. Leave a gap between the frame and the insulation, and the cold reaches the plasterboard lining, which then shows as a darker, damp-looking band in the corners of the reveal each winter.
The upstand also affects the light, which is why we consider the two together. A deep, narrow kerb in a thick roof acts like a short tunnel, cutting the angle of sky the room sees. Splaying the internal lining outwards towards the room lets the light spread wider and, as a side effect, gives more room to place insulation on the cold side. The same detail that spreads the light can also cut the heat loss.
Joints, gaps and moving air
Air leakage is the heat loss route that ignores U-values completely. Warm air escaping through a gap takes its heat with it, and a surprisingly small gap at roof level can move a lot of air, because warm air rises and presses outwards at the top of a room.
That upward pressure, the stack effect, is strongest at the highest point of the heated space, which is exactly where a rooflight sits. A draughty joint in a wall window at knee height leaks less than the same joint in a skylight at the top of a double-height stairwell. There are three places to look.
- Between the frame and the kerb or rafters. This joint is sealed during installation, not in the factory. It needs an airtight seal on the room side and a weathertight seal on the outside, with the vapour control layer of the roof taped to the frame so it runs continuously.
- Around the opening sash. Opening rooflights rely on compression seals. Once those age or the sash no longer closes evenly, they let air through every time the wind picks up.
- Through the lining. Downlights, cable holes and unsealed plasterboard joints in the reveal let warm, moist air into the cold roof zone around the unit, where it loses heat and can condense.
There is a second kind of moving air that feels like a draught even when every joint is sealed. Air in contact with cold glass cools, becomes denser and sinks. Under an older single- or early double-glazed skylight that falling air can be felt as a steady cold flow onto a sofa or a dining table below. It is a comfort problem more than an energy one, and it largely disappears once the inner pane runs warmer. Our answer on why a rooflight feels cold underneath covers it in more depth.
Putting rough numbers on a Cambridge winter
A worked example shows the scale. The figures below are illustrative physics, not a measurement of any particular unit, but they show which improvements move the result and which barely register.
Take a single 1m by 1m flat rooflight in an otherwise well-insulated extension roof. On a cold night with the room at 20°C and 0°C outside, heat flow is the whole-unit U-value multiplied by the area and the temperature difference. Across a whole heating season, a common rough measure is heating degree days; eastern England sees somewhere around 2,000 of them a year, and multiplying by U, area and 24 hours gives an approximate annual figure in kilowatt hours.
| What fills the 1m² | U (W/m²K) | Watts at 20°C gap | Rough kWh a year |
|---|---|---|---|
| Insulated roof | 0.15 | 3 | 7 |
| Modern triple | 0.9 | 18 | 43 |
| Modern double | 1.3 | 26 | 62 |
| Early double | 2.8 | 56 | 134 |
| Single glazed | 5.8 | 116 | 278 |
Three things stand out. First, the jump from single glazing to any modern sealed unit is far larger than anything that follows. Second, going from a good double to a triple saves a modest amount on a single metre of glass; it is more worthwhile where there is a lot of roof glazing, such as a large lantern or several rooflights in one room. Third, none of these figures include a poorly insulated kerb, a gap in the roof insulation or a leaking seal, which can add a real share on top of the unit itself.
Against that loss, a skylight also brings heat in. On a clear winter day the low sun delivers some solar gain even through a flat pane, and a south-facing roof window catches more. Over a whole Cambridge winter a north slope gains little, so its losses stand largely unoffset. The balance by orientation is covered in whether north facing rooflights lose more heat, and the sunny-day side in whether a skylight can warm a room in winter.
What to prioritise, in order
If the aim is a rooflight that stays warm to the touch and costs little to heat under, the order in which the routes are dealt with matters more than any single headline figure.
- Get rid of single glazing and failed units first. A single-glazed dome, a wired-glass pane or a sealed unit that has misted between the panes is the largest single loss in the roof. The upgrading single-glazed rooflights guide covers the options.
- Choose a frame with a proper thermal break, or a timber or uPVC frame, together with warm edge spacers. This deals with the cold border where discomfort and condensation start.
- Insulate the upstand or lining and join it to the roof insulation with no gaps. This is installation work, and it is invisible once the room is finished, so it is worth asking how it will be done before the job starts.
- Seal the frame to the air barrier on the room side and weatherproof it outside, and make sure an opening sash closes evenly on its seals.
- Then decide on the glass build-up. A low-E, argon-filled double unit meets current standards; triple glazing is worth considering on a north slope, a large lantern or a room heated by a low-temperature heat pump.
Where the work is notifiable, the replacement or new unit must meet the limiting values set by Building Regulations, currently 2.2 W/m²K for a rooflight assessed horizontally. Most modern double-glazed units comfortably pass that. The detail is on the Part L requirements for rooflights page.
How winter losses shape the light plan
Heat and light are planned together, because the choices that cut winter loss also change what the room looks like on a grey February afternoon. Each extra pane and coating trims a little of the daylight that reaches the floor.
On a north slope in a Petersfield terrace, where the roof gets no direct winter sun at all, the skylight gives steady, soft light and loses heat every hour of the heating season. That is the case where a triple unit, a warm edge and a well-insulated lining pay their way, and where a slightly lower light transmission is a fair trade. On a south-facing slope at Trumpington Meadows the same room might gain useful sun on bright winter days but overheat in July, so the glass is chosen more for summer control and the winter loss is handled by the frame and upstand detail.
Size and placement play a part too. One well-placed opening over the part of the room you use will often do the lighting work of two smaller ones, with less total edge and frame to lose heat through. Setting the unit away from a cold external wall corner, and keeping the reveal short where the roof build-up allows, helps both the light and the warmth.
At the survey we look at the slope, the roof build-up and how the room is used, then write down the unit, glass, frame and upstand detail in the light plan that comes with the quote. If you are planning a new rooflight or replacing an old one and want to know how it will behave in winter as well as summer, book a light survey or message us on WhatsApp.
Questions people ask
Is it normal for frost to form on the outside of a new rooflight?
Yes. A well-insulated unit keeps room heat away from the outer pane, so on a clear night that pane can drop below freezing and frost over. It clears once the sun reaches it. Frost is a sign the glass is doing its job, not a fault.
Will a thicker blind stop the heat loss through a skylight at night?
A close-fitting insulating or blackout blind does reduce night-time loss and the cold downdraught, especially under older glass. It traps a layer of air against the pane. It does not touch the losses through the kerb, the frame or air gaps, and it has to be open by day for the light.
Does replacing the glass alone fix a cold rooflight?
Only if the glass was the main problem. If the frame is unbroken aluminium, the kerb is bare timber or the roof insulation stops short of the opening, new glass leaves those routes in place. Replacing the whole unit and rebuilding the upstand detail deals with all of them together.