Question

Can a flat rooflight be fitted to an existing roof?

The short answer

Yes. A flat rooflight can be fitted to an existing roof when three things check out: the joists can be trimmed around a new opening, the covering has enough life left to be weathered into a new upstand, and the insulation build-up is known, so the kerb can be set high enough and the insulation line carried round it without a cold gap.

Reading the roof you already have

Before anyone talks about glass, a retrofit starts with finding out how the existing roof was put together, because a flat roof gives away very little from either side.

From the garden you see a covering and an edge trim. From the room you see a plastered ceiling. Between the two there is a deck, a set of joists and, somewhere in that sandwich, some insulation or none at all. A single-storey kitchen added behind a Mill Road terrace in the 1980s is likely to be a cold deck: felt on chipboard or plywood, joists below, and a thin layer of mineral wool laid on the ceiling. A side-return extension built on a Petersfield or Romsey terrace in the last fifteen years is more likely to be a warm deck, with rigid insulation boards on top of the timber and the membrane over those. A garage or utility roof on a 1960s house may have no insulation at all.

At the survey we find out which one you have without guessing. The simplest routes are an existing opening (a roof vent, a light fitting, a cable run), the depth of the roof edge compared with the joist depth, and the completion paperwork if the extension was signed off. Where none of those settles it, a small inspection opening in the area that will be removed anyway for the rooflight answers the question before anything is ordered.

Structure: can the joists take an opening?

Cutting a rooflight into an existing roof means one or more joists stop short, and their load has to be picked up by the timbers either side.

For a modest skylight, say 600mm by 900mm between joists at 400mm centres, one joist is cut, trimmers are fixed across the ends, and the two full-length joists alongside are doubled. That is routine carpentry. As the opening grows, more joists are cut, and past a certain width the trimming joists need to be sized by calculation or replaced with an engineered timber or steel member. Joist depth, span, centres and what else the roof carries (a condenser unit, solar panels, a sedum layer) all feed into that decision. Our separate answer on whether a flat roof needs strengthening for a rooflight goes into the trimming detail.

The retrofit twist is direction. The joists already run one way, and the rooflight is easiest to fit with its long side running along them. Turning a long rectangular unit across the joists cuts more of them for the same glass area, so the direction of the existing joists quietly shapes the rooflight you end up choosing.

Covering: is there enough life left in it?

A new rooflight is weathered into the existing covering, so the covering has to be worth weathering into.

EPDM and GRP roofs from the last decade or so usually take a new upstand well: the membrane is cut back, the kerb goes in, and new material is bonded up the kerb and lapped onto the old. Older built-up felt is a different conversation. Felt that is blistered, crazed or brittle does not hold a new lap reliably, and a rooflight dressed into it will outlast the roof around it. In that case the sensible answer is to renew the covering at the same visit, which also gives the chance to upgrade the insulation. Lead, zinc and green roofs each have their own detail, covered in our guide to flat rooflights and roof coverings.

Falls matter as well. The glass needs about 5 degrees of fall for water to clear, which the kerb or the unit provides, but the roof around it must still drain. A rooflight placed across the path water currently takes to the gutter creates a dam, so the position is checked against the existing falls as well as against the room below.

Section through a flat-roof rooflight: joists and trimmers, deck, insulation laid to falls, a kerb at least 150mm above the finished roof with the membrane dressed over it, the rooflight unit and a plastered reveal.150mm1:4012345678
Fig. Section through a flat-roof rooflight on a warm-deck roof, drawn at about 1:20.
  1. Joists, with doubled trimmers either side of the opening to carry the loads of the cut joists around it.
  2. Deck (usually 18mm ply or OSB) with a vapour control layer laid on it.
  3. Insulation boards above the deck (a warm roof), often tapered to give the roof its falls.
  4. Waterproof membrane dressed up the upstand and over its top, so the joint is lapped, not sealed.
  5. Upstand, or kerb: insulated timber, finishing at least 150mm above the finished roof surface to keep standing water and splash off the joint.
  6. Rooflight unit fixed over the kerb, its frame skirt shedding water outside the membrane turn-up.
  7. Plastered reveal lining the opening from the ceiling up to the frame, finished white to bounce the light down.
  8. Roof falls to an outlet: designed at about 1:40 so the finished roof never falls less than 1:80.

Insulation depth and the height of the kerb

How much insulation sits in the roof, and where, decides how tall the upstand has to be and how the rooflight is kept free of condensation.

The kerb must stand at least 150mm above the finished roof surface. On a warm deck, the finished surface is the top of the insulation boards, which may be 120mm to 150mm above the timber deck, so the upstand is built taller to clear it and the boards are cut tight around the kerb. The detail is set out in our answer on fitting a rooflight to a warm deck flat roof. On a cold deck, the insulation is between or below the joists, so the light well that runs down through the joist zone passes straight through it. That reveal has to be lined with insulation and a vapour barrier, otherwise the linings of the well become the coldest surface in the room and collect condensation each winter. The answer on vapour control layers covers that part.

An uninsulated roof is the one case where the rooflight exposes a wider problem: a new unit meeting Part L will be far warmer than the roof around it. That is not a reason to stop, but it is worth knowing before the ceiling is opened.

What you haveWhat it means for the retrofit
Warm deck, sound membraneTaller kerb to clear the insulation; covering lapped up
Cold deck, sound coveringWell lined with insulation and a vapour barrier
Old, brittle feltRenew the covering at the same visit
No insulationRooflight fits; a roof upgrade is worth weighing up

Where the light can land in a finished room

A retrofit has fewer free choices than a new build, so the light plan works around what the room already has.

In a new extension the rooflight can go wherever the drawings put it. In an existing kitchen, the joist layout, a party wall, downlights, an extractor duct and the fall of the roof all narrow the options. A rooflight within 1500mm of a party wall is out, for fire-spread reasons explained in our answer on how close a rooflight can be to a party wall. Within what is left, we use the sun path over the roof to place the opening where it helps: over the worktop rather than the fridge, or near the back wall of a deep rear extension so the far end of the room stops feeling like a corridor. On a roof shaded by the house to the south, a rooflight in the back half of the extension sees much more sky than one tucked against the house wall. Our guide to positioning a flat roof skylight goes further, and how we plan the light explains the method.

Permission and paperwork for a retrofit

Adding a rooflight to an existing flat roof is often permitted development, but it is always a Building Regulations matter.

For a house outside a conservation area or Article 4 area, a flat rooflight that does not project more than 150mm above the roof plane is usually permitted development. Listed buildings, flats and some conservation areas need an application, and our answer on whether a flat rooflight needs planning permission sets out the cases. Cutting a new opening is structural and changes the thermal envelope, so Building Control is notified. We handle that notification where the work is notifiable, and install to current Building Regulations, including the Part L limit of 2.2 W/m²K for the rooflight.

On the day, a straightforward retrofit follows the sequence in our flat roof skylight fitting guide: protect the room, open the ceiling, trim the joists, build and insulate the kerb, weather it in, fit the unit, then line and plaster the well. More on the service as a whole is on our flat roof rooflight installation page.

Questions people also ask

Can I stay in the house while a rooflight is retrofitted?

Yes. The room below is sheeted and screened while the ceiling is open, and the roof is made weathertight before the end of each working day. The rest of the house carries on as normal.

How deep will the light well be?

The light well runs from the rooflight down to the existing ceiling, so its depth is the joist zone plus the deck and the kerb. On a cold deck that is often 250mm to 400mm, and it can be finished square or splayed to spread the light wider across the room.

Can an old skylight be swapped for a bigger one?

Often, yes. The existing opening is widened by trimming more joists, and the new kerb is weathered into the covering. The same checks on structure, covering and insulation apply as for a brand new opening.

Is a survey needed before a quote?

Yes, because the joists, the covering and the insulation depth are what set the detail and the price. Book a light survey and every quote comes with a written light plan.