Question

Does a flat rooflight need a vapour control layer?

The short answer

Yes, in the sense that the roof around it does, and the rooflight has to join that layer without a gap. The vapour control layer stops warm, damp room air reaching the cold parts of a flat roof. Where a skylight goes in, the layer is cut, so it must be carried up the upstand and sealed to the frame, or moisture finds the break.

What the vapour control layer is doing up there

A vapour control layer is a sheet, usually a reinforced polythene, a foil-faced membrane or a bitumen-based layer, placed on the warm side of the insulation so that water vapour from the house cannot pass into the roof and condense where it is cold.

Warm air holds more moisture than cold air. A kitchen with a pan on the hob, a bathroom after a shower, or a bedroom with two people asleep in it all push water vapour up towards the ceiling. If that vapour can drift into the roof build-up, it keeps going until it meets a surface below its dew point, then turns back into water. In a flat roof that surface is usually the underside of the waterproof covering or the cold face of the insulation. The water collects out of sight, soaks the deck or the boards, and shows up months later as a stain on the ceiling that looks, to anyone standing below, exactly like water coming in from outside.

Approved Document C of the Building Regulations requires roofs to be designed so that condensation within the construction does not harm the building, and it points to BS 5250, the British Standard on managing moisture in buildings. The vapour control layer is the main tool for doing that on a flat roof. A rooflight does not change the principle. It just puts a large hole in the layer, at the point where the warmest, dampest air in the room tends to gather.

Why the opening is the weak point

Warm air rises and collects at the highest part of the ceiling, and a rooflight well is exactly that: a short shaft reaching up out of the room, lined with timber and plaster, with the coldest surface in the whole ceiling at its top.

When the opening is cut, the vapour control layer is cut with it. If it is simply trimmed back to the edge of the hole and left, room air can travel round the end of the sheet, into the gap between the upstand and the insulation, and up into the roof. The plasterboard lining of the reveal is not a vapour barrier on its own, and nor are the screw holes, the joints at the corners, or the gap where the lining meets the frame.

The effect is concentrated. Over a kitchen island or a hob run, a flat skylight sits in the path of the steam, and its reveal is the first thing that steam meets. That is why a vapour control layer that is sound across the rest of the roof can still fail at the one place the homeowner looks at every day.

How the layer is carried up to the rooflight

The answer is continuity: the vapour control layer is turned up the kerb and sealed to the rooflight so that there is no route for room air round its edge.

The exact detail depends on the roof build-up, but the sequence on a typical extension roof runs like this:

  1. The opening is trimmed and the upstand is fixed to the deck or the joists.
  2. The vapour control layer on the deck is cut with enough spare to lap up the face of the kerb, rather than trimmed flush.
  3. It is dressed up the upstand and bonded or taped to it, with the corners folded and sealed rather than slit and left open.
  4. At the top of the kerb it is sealed to the underside of the rooflight frame or to the maker's vapour seal, using the tape or sealant the rooflight system specifies.
  5. Insulation and the roof covering then go on over it, and the reveal is lined inside only after the seal has been checked.

On a warm deck the layer sits on top of the timber deck, so it turns up the outside face of the upstand under the insulation boards. Our answer on fitting a rooflight to a warm deck covers how that insulation joins the kerb. On an older cold deck, where the insulation sits between the joists, the vapour control layer is at ceiling level, so it is taped to the inside of the trimmed opening and to the lining of the light well instead. The upstands guide explains the kerb types these layers are sealed to.

Where it matters most in Cambridge homes

The risk rises with the humidity of the room and the coldness of the roof, so the detail deserves the most care where the two meet.

SituationWhy it needs care
Kitchen extensionSteam rises straight to the rooflight well
Bathroom or en suiteHighest humidity in the house
Older cold deck roofLayer at ceiling level, easy to break
Rooflight added laterExisting layer cut, must be rejoined

The side-return and rear kitchen extensions behind terraces in Romsey, Petersfield and Chesterton are the classic case: a small, busy room, a flat roof, and a skylight placed over the cooking area because that is where the light is wanted. Garage conversions and older flat-roofed extensions on post-war houses can have cold deck roofs, where the layer is a sheet of polythene above the ceiling and is easy to tear when the opening is cut from below.

Ventilation helps too. An opening rooflight lets moist air out at the highest point of the room, which is where it collects. Our guide to fixed and opening flat rooflights covers which rooms benefit, and a cooker hood extracting to outside does more than any rooflight can.

Adding or replacing a skylight in an existing roof

Retrofitting is where continuity is hardest, because the vapour control layer already exists and is being cut in place rather than laid around a planned opening.

When a new flat rooflight goes into an existing roof, the roof is opened up enough to find the vapour control layer, check it is intact and dry, and rejoin it to the new upstand with compatible tape before the roof is closed. If the boards or deck around the opening are wet when they are exposed, that points to moisture already in the roof, and it is dealt with before the rooflight is fitted rather than sealed in. Our answer on fitting to an existing roof covers the other checks.

When an older unit is replaced, the same joint is renewed. Older skylights were sometimes fitted with the layer trimmed short, and staining in the corners of the reveal can be the first sign. Replacing the unit is a good moment to put that right. Where the work is notifiable, we handle the Building Control notification, and the seal is checked before the lining goes back, as part of the fitting sequence. The wider service is set out on our flat roof rooflight installation page.

Questions people also ask

Is condensation on the glass the same problem?

No. Droplets on the inside face of the glass on a cold morning are surface condensation, which you can see and wipe. A missing vapour control layer causes condensation inside the roof, which you cannot see until it stains the ceiling. Better glass reduces the first; only the sealed layer prevents the second. Our glazing guide covers the glass.

Does the rooflight maker supply the vapour seal?

Many flat rooflight systems include a vapour control collar or specify a tape for the joint between frame and upstand. Where one is supplied, it is used; where it is not, the roofing layer is taped to the kerb with a compatible product.

Can the vapour control layer be added from inside later?

Partly. On a cold deck, a vapour-check plasterboard or a taped membrane can be fitted to the ceiling and the reveal, but it is harder to make continuous than a layer fitted at roof level. It is simpler to get it right when the rooflight goes in.

Will the light well show where the seal failed?

Usually, yes. The top corners of the reveal are the coldest point, and grey spotting or damp plaster there is the typical sign. A light, matt painted reveal also bounces more daylight into the room, as our page on how we plan the light explains, so it is worth keeping clean and dry. If you want the detail checked on your roof, book a light survey.

Book a light survey

Tell us about the room

  • No obligation
  • Light plan in writing
  • 10-year guarantee