What the kerb is actually doing
A flat rooflight upstand, also called the kerb, is the short wall built around the roof opening that the glass sits on. It keeps water away from the glass edge, gives the roof covering somewhere to finish, carries the fixings and usually sets the fall of the glass.
From the garden you barely see it. From inside you look up through it. It is easy to treat the upstand as a bit of carpentry that happens before the real product arrives, but on a flat roof it does more work than any other single part of the installation. A good unit on a poor kerb will stand in water, sit at the wrong angle and leave a cold edge around the opening. A modest unit on a well-built kerb will shed rain, stay warm at the reveal and look deliberate.
It helps to list the jobs separately, because each one sets a different dimension:
- Height. The kerb lifts the glass clear of water that sits or runs on the roof surface, and gives the waterproof covering a vertical face to turn up against and terminate.
- Fall. A kerb that is taller on one side than the other tilts the glass so rain runs off rather than lying on it.
- Fixing. The rooflight frame, or on a frameless unit the glass itself, is fixed or bonded to the top of the kerb, so its top edge has to be flat, square and the right size.
- Insulation. The kerb is part of the roof's thermal envelope. If it is not insulated to match the roof, the edge of the opening becomes the coldest surface in the room.
- The light well. Inside, the kerb adds to the depth of the shaft that daylight passes through before it reaches the ceiling line, which changes how much sky the room sees.
The rest of this guide takes those jobs one at a time. It sits under our main page on flat roof rooflight installation in Cambridge, which covers the whole project from survey to handover.
The 150mm minimum, and where you measure it from
Flat roofing guidance from the single-ply and membrane trade bodies asks for the waterproof covering to turn up at least 150mm above the finished roof surface at any upstand. For a flat skylight upstand, that means the lowest side of the kerb, not the average and not the tall side.
The figure exists for plain physical reasons. Rain hitting a flat roof splashes. Wind drives water along the surface and up against anything standing proud of it. A blocked outlet or a shallow dip lets water pond for a day or two, and in a cold spell snow can sit against the kerb and melt slowly. The 150mm upturn keeps the top edge of the membrane, and the joint between the covering and the rooflight frame, above all of that.
The word that matters is "finished". The height is taken from the top of whatever ends up on the roof, not from the deck. On a bare membrane roof the two are almost the same. On other roofs the difference is large:
- A ballasted single-ply roof with a layer of pebbles loses the depth of that ballast.
- A roof terrace with paving on pedestals may lift the walking surface 50 to 100mm or more above the membrane.
- A sedum or green roof adds its drainage layer, substrate and plants, and the kerb has to clear all of it with a gravel margin around it. The answer on fitting a flat rooflight on a green roof goes into that build-up.
- A roof that is going to be overlaid with new insulation later, as part of a warm deck upgrade, will rise by the thickness of those boards.
So the kerb is sized from the roof as it will be finished, not as it is on the day the opening is cut. We check this at the survey, because an extension roof drawn as bare membrane can end up with paving on it two years later. The separate answer to how high a flat rooflight upstand should be covers the cases where a taller kerb is worth having even on a plain roof.

Timber kerbs built on the roof
The traditional flat rooflight upstand is a box of treated softwood built directly on the roof structure around the opening. It is cheap in material, can be made to any size or shape, and a good carpenter can build in the fall as they go.
A site-built kerb is usually framed from pressure-treated timber, sheathed in exterior grade plywood or OSB, and fixed down through the deck into the joists and the trimmers that frame the opening. On a larger rooflight it may be two layers of timber, or deeper sections, so that it stays rigid while the glass is lifted on and does not twist as the timber dries. The top has to be flat along each side and square across the diagonals, because a rooflight frame will not pull a twisted kerb straight, and on a frameless unit any twist shows as an uneven silicone joint.
The weakness of a plain timber kerb is heat. Softwood is a far better insulator than steel or concrete, but a 47mm stud wall with no insulation behind it is still much colder than the 120 to 150mm of rigid board on a modern warm deck. The standard answer is to line the kerb: insulation board fixed to the outside face under the membrane upturn, the inside face, or both, so the thermal line of the roof carries up and round the opening without a gap.
Timber kerbs suit roofs that do not fit a standard size, openings where the fall has to go an unusual way, and older extensions where the roof is being stripped and rebuilt anyway. They take longer to build than a factory upstand, and the quality depends entirely on the person holding the saw.
Factory insulated upstands
An insulated upstand is a prefabricated kerb, usually a rigid insulation core in a PVC, GRP or composite skin, made to match a particular rooflight. It arrives square, at the right size and often with the fall already built in.
Many rooflight manufacturers offer one to pair with their own units, and some supply the rooflight already mounted on its upstand. The advantages are consistency and speed. The kerb has a declared thermal performance, the top dimensions match the frame exactly, and the fixing points are where the manufacturer expects them. On a new extension with a regular opening, fitting a factory upstand can take a fraction of the time of building one.
The limits are size and compatibility. Factory upstands come in set heights and footprints, so an odd-sized opening or a deep ballasted roof may need a timber base under the upstand, or a timber kerb instead. The skin also has to suit the roof covering: EPDM, single-ply, GRP, felt and metal all bond or dress in different ways, and the membrane manufacturer's guidance on what it will adhere to has to be followed. The guide to flat rooflights and roof coverings sets out how each covering is weathered into the kerb.
| Point | Site-built timber | Factory insulated |
|---|---|---|
| Size | Any size or shape | Set sizes, matched to unit |
| Fall | Built in by the carpenter | Often pre-formed |
| Insulation | Added by lining | Built into the core |
| Time on roof | Longer | Shorter |
| Best for | Odd openings, rebuilds | New, regular openings |
Neither is better in every case. The right kerb is the one that suits the roof build-up, the opening and the unit, and the choice is written into the light plan with the reason for it.
How the upstand sets the pitch of the glass
A flat rooflight is never quite flat. The glass needs a fall of around 5 degrees so rain runs off, and very often it is the upstand, taller on one side than the other, that provides it.
Some units have the pitch built into the frame, so they can sit on a level kerb. Others, particularly many frameless designs, rely on a kerb built to a fall. Where the roof itself already falls in the right direction, the kerb only has to make up the difference. The answer on the minimum pitch for a flat rooflight explains why 5 degrees is the working figure and what happens to glass laid flatter.
- Joists, with doubled trimmers either side of the opening to carry the loads of the cut joists around it.
- Deck (usually 18mm ply or OSB) with a vapour control layer laid on it.
- Insulation boards above the deck (a warm roof), often tapered to give the roof its falls.
- Waterproof membrane dressed up the upstand and over its top, so the joint is lapped, not sealed.
- Upstand, or kerb: insulated timber, finishing at least 150mm above the finished roof surface to keep standing water and splash off the joint.
- Rooflight unit fixed over the kerb, its frame skirt shedding water outside the membrane turn-up.
- Plastered reveal lining the opening from the ceiling up to the frame, finished white to bounce the light down.
- Roof falls to an outlet: designed at about 1:40 so the finished roof never falls less than 1:80.
The geometry is simple enough to check with a tape. A 5 degree fall rises about 87mm for every metre of run. So a kerb under a rooflight that is 1200mm in the direction of the fall is roughly 105mm taller on its high side than its low side. Because the low side still has to be at least 150mm above the finished roof, the high side of that kerb ends up around 255mm. On a 2000mm unit falling along its length, the difference is about 175mm, and the high side reaches around 325mm. That is why a long rooflight is usually set to fall across its shorter dimension.
Direction matters as much as angle. The low edge should discharge onto the roof towards the outlets or gutter, not towards a parapet, a house wall or the joint where the extension meets the main house. Water leaving the glass arrives at the kerb in a concentrated line, so the roof below that edge needs a clear run to drain. On a parapet roof or a narrow side return, where the roof is boxed in by walls, the direction of fall is often decided by where the outlet is before anything else.
A tall high side has a second effect: it shows. On a single-storey extension seen from bedroom windows above, a steeply tilted kerb reads as a lump. Setting the fall across the shorter side and using a unit with some pitch in its own frame keeps the profile low.
Keeping the insulation line unbroken
The opening cut for a rooflight is a hole in the roof's insulation, and the upstand is where that hole is closed again. If the kerb is colder than the roof around it, the reveal inside will be the first surface to collect condensation on a winter morning.
On a warm deck roof, where the insulation sits above the deck and under the membrane, the kerb has to carry insulation of a similar thickness up its outer face to meet the rooflight frame. The membrane then runs over that insulation and up to its termination. The answer on fitting a rooflight to a warm deck flat roof shows how the layers turn the corner. On a cold deck roof, with insulation between the joists, the kerb is insulated inside, where the lining meets the ceiling insulation, and the ventilation of the void around the trimmers has to stay open.
The vapour control layer matters here too. It sits on the warm side of the insulation, and around a rooflight it has to be carried up the kerb and sealed to the frame, otherwise moist air from a kitchen or bathroom finds its way into the roof build-up around the opening. The answer on whether a flat rooflight needs a vapour control layer covers the detail.
What the kerb does to the light in the room
From inside, the daylight has to travel down a shaft before it reaches the ceiling line: the kerb, the roof depth and the ceiling below. The taller that shaft, the less sky the room sees, and the more the light is shaped by the reveal.
A typical extension roof, with joists, a warm deck and a plasterboard ceiling, is already around 250 to 350mm deep. Add a 150mm kerb on the low side and 250mm or more on the high side, and the light well can be half a metre deep or more. On a small rooflight that depth has a real effect. The opening frames a narrower cone of sky, and direct sun only reaches the floor when it is high enough to clear the rim of the well. The unit's own thickness adds a little more, which the answer on how thick a flat rooflight is sets out.
Orientation decides which side of the well matters. In Cambridge the winter sun at noon is only about 14 degrees above the horizon, rising to about 61 degrees at midsummer. Through a deep well, the low December sun barely reaches below the ceiling, so the room gets soft sky light rather than a sun patch. In June the high sun drops straight in and lands a bright rectangle on the floor or worktop. If the tall side of the kerb faces south, it shades the glass a little on winter afternoons; if it faces north, the south edge sits lower and lets more low sun through. That is one reason the direction of fall is part of the light plan rather than just the drainage.
The reveal itself can help. Splaying the internal lining outward, so the opening is wider at the ceiling than at the glass, spreads the light across more of the room and softens the edge between bright glass and dark ceiling. A white or pale reveal bounces light further than a dark one. On a narrow room such as a side return, a splayed reveal on the long sides can make a modest rooflight feel much larger. Our page on how we plan the light explains how we weigh these choices against the room below.
Replacing a rooflight on an old kerb
When an older flat skylight is replaced, the existing upstand decides a lot about the job. Some kerbs can be kept and reused; others are the reason the old unit failed.
Older extensions around Cambridge, from the flat-roofed kitchen additions on 1960s and 1970s houses to the early side returns on Romsey and Mill Road terraces, often have kerbs that would not be built today. Common findings include a kerb well under 150mm, especially once the roof has been re-covered and raised; a kerb built level with no fall, relying on a domed unit to shed water; bare timber with no insulation; and sheathing that has softened where the old covering stopped short.
Whether the kerb stays depends on three checks: its height above the finished roof, its condition when the old covering is peeled back, and whether its top matches the size and fall the new unit needs. A flat glass unit replacing an old polycarbonate dome is the classic case for rebuilding, because the dome shed water by its shape and the new glass needs the kerb to provide the fall instead. When the kerb is rebuilt, the roof covering around it is renewed at the same time so the upturn is continuous.
The fitting order for either case is set out in the guide to flat roof skylight fitting step by step. If you want the kerb on your roof looked at before choosing a unit, book a light survey and we will measure it, open the covering where needed and put the answer in the written light plan.
Questions people ask
Can a flat rooflight sit directly on the roof without an upstand?
No. Without a kerb the frame or glass edge would sit in the water running across the roof, the covering would have nothing to turn up against, and there would be no simple way to give the glass its fall. Even units sold as low profile still sit on a kerb; it is simply shorter above the frame or partly hidden within the roof build-up.
Does a taller upstand make the rooflight more likely to need planning permission?
It can. When a rooflight is added to an existing roof, permitted development generally allows it to project no more than 150mm beyond the roof plane, and a kerb plus the unit can exceed that. On a new extension the rooflight is usually assessed as part of the extension. Where the height is close, it is worth checking with the council before the kerb is built.
Should the upstand be the same size as the opening in the ceiling?
The kerb's outer size is set by the rooflight, and its inner face forms the top of the light well. The ceiling opening can be the same size for a crisp, straight-sided reveal, or larger if the lining is splayed to spread the light. That choice depends on the room and is agreed before the roof is opened.