What polycarbonate was doing on your roof
Polycarbonate went onto thousands of UK roofs because it was light, cheap and easy to cut, and on a lean-to or a small flat roof it did its job for a while. Replacing it with glass today is an upgrade on four fronts at once: clarity, quiet, warmth and the way the light sits in the room.
You will usually find polycarbonate in one of three places. The first is the multiwall sheet: twinwall or triplewall panels, often 10mm to 25mm thick, clipped into aluminium or plastic glazing bars on a lean-to, a covered side passage or a conservatory roof. The second is the moulded dome or pyramid on a kerb, common over flat-roofed kitchens and bathrooms built from the 1970s onwards. The third is a flat single or twin-skin polycarbonate rooflight on a timber upstand, often found on garage conversions and single-storey rear extensions where the original builder wanted something that would not break if a ladder slipped.
In Cambridge all three turn up behind gault brick terraces in Romsey and Petersfield, where a narrow side return was roofed over decades ago, on 1930s semis in Cherry Hinton and Arbury with a flat-roofed kitchen at the back, and on village bungalows around Histon, Cottenham and the Shelfords. The material was chosen for cost and weight. It was never chosen for the light it would give a room twenty years later, and that is the gap a glass replacement closes.
This guide is about moving from polycarbonate to glass specifically. If your unit is a plastic dome and you are mostly weighing a new dome against a flat glass rooflight, the guide to replacing dome rooflights goes deeper into the upstand side of that choice.
Why the sheet has turned yellow and dull
Polycarbonate is a plastic that slowly breaks down in ultraviolet light. Sheets are made with a thin UV-resistant layer on the outer face, and once that layer has weathered away the plastic underneath begins to yellow, haze and lose strength.
The change is gradual, which is why it is easy to stop noticing. A kitchen that once had a bright pool of daylight ends up with a flat, slightly amber cast, and you find the lights going on at three in the afternoon in October. Several things are happening together:
- Yellowing. UV breakdown shifts the colour of the transmitted light towards amber, so white walls and worktops read as cream and food looks different under it.
- Surface haze. The outer face becomes micro-crazed and chalky, which scatters light and holds dirt, so the sheet looks grubby even after a wash.
- Green and black growth. Multiwall sheets have open flutes. Where the end tape has failed, moisture and algae get into the channels and you see dark lines running down the length of the panel.
- Brittleness. Aged polycarbonate loses much of the impact resistance that made it attractive in the first place, and older sheets can crack at fixing points or around the edges.
None of this can be reversed by cleaning. Polishing compounds can take off a little surface bloom, but they also strip whatever protection remains, and the yellowing runs through the material itself. The answer page on why a rooflight goes cloudy covers how to tell polycarbonate ageing from a failed sealed unit or worn coating, because the replacement route differs for each.

What glass changes about the light in the room
Clear double glazing lets through more daylight than aged polycarbonate and, just as importantly, lets it through without colour. The room goes from a soft amber glow to real daylight with a direction to it.
That second point is the one to plan for. Opal and aged polycarbonate diffuse the light, spreading it evenly across the ceiling and walls with no sharp sun patch. Clear glass does not. On a south-facing slope or a flat roof in summer, the sun comes straight through and draws a bright, well-defined shape on the floor or the worktop that moves across the room through the day. In February, with the sun low over the Fens, that patch can reach well up a wall. In June it sits almost directly under the opening around midday.
For a kitchen or a family room this is usually exactly what people want: a room that feels outdoors-bright in the morning and has a sense of time passing. For a home office, a room with a television on the wall, or a narrow side return where the light lands on the dining table at lunchtime, it is worth deciding in advance how sharp you want it. There are three levers:
- Glass type. A solar control or neutral-tinted outer pane cuts heat and brightness without the yellow cast. An obscure or satin-finish inner pane restores the diffusion of the old sheet while keeping the clarity and thermal gains of glass.
- Position. Replacement is a rare chance to move or resize the opening so the light falls where the room is used. The guide to repositioning a rooflight when replacing it explains when this is worth doing.
- Shading. An internal blind or an external shade gives day-by-day control, particularly on south and west roofs.
Our light planning page shows how orientation and season shape that sun patch, and the answer on whether a new rooflight will be brighter explains when coatings trade a little brightness for comfort.
- Outer toughened pane: heat-strengthened to take hail, foot traffic during maintenance and thermal stress.
- Solar-control coating (optional) on the inside face of the outer pane, cutting heat gain on south and west roofs.
- Argon-filled cavity: a denser gas than air, so less heat crosses the gap.
- Warm-edge spacer: a low-conductivity edge that keeps the units’ edges warmer and cuts condensation at the frame.
- Low-E coating: a microscopically thin metal layer on a cavity face that reflects room heat back inside.
- Inner laminated pane: two sheets bonded to an interlayer, so if it ever breaks, the glass stays in place overhead.
- Triple glazing only: a third pane and a second argon cavity, usually with a second low-E coating. Warmer, heavier, and it lets in slightly less light.
Warmth, heat and the Part L numbers
Swapping polycarbonate for a modern double or triple glazed skylight usually improves the thermal performance of that part of the roof, and it has to: replacement roof glazing in an existing home is expected to meet the current Part L standard.
Multiwall polycarbonate varies widely. Thin twinwall sheet insulates poorly, and even thick multiwall panels tend to sit around or above the Part L limit once you account for the glazing bars and the gaps at the ends. Moulded single-skin domes insulate very little. Approved Document L (2021) sets a limiting U-value of 2.2 W/m²K for rooflights in existing dwellings, measured in the horizontal plane, and a well-specified double glazed flat rooflight or lantern can come in comfortably below that. Triple glazing goes further again.
In practice the difference shows up in three places. In winter, the area under the old sheet stops feeling like a cold spot, and the down draught that runs off cold overhead glazing is much reduced. Condensation on the inside face becomes far less likely, because the inner pane of a sealed unit stays much closer to room temperature. And in summer, a glass unit with a low solar gain coating lets in daylight while holding back more of the heat, which matters on the flat-roofed rear kitchens in Cambridge where the whole roof sees the sun from mid-morning to evening.
For the numbers behind this, including how a failed or poor unit affects a heating bill, see the answer on whether a misted rooflight loses heat.
A quieter room when it rains
Rain on thin polycarbonate drums. Glass, and especially laminated glass, damps that noise so heavy rain becomes a soft background sound rather than something you have to talk over.
The reason is mass. A multiwall sheet weighs very little per square metre and acts like the skin of a drum: each drop sets it vibrating, and the hollow flutes can amplify the sound. A sealed glass unit is many times heavier, with two or three panes separated by gas-filled cavities, and a laminated inner pane adds a plastic interlayer that absorbs vibration. The practical effect is most noticeable in kitchens and side-return dining rooms directly under the roof, and in bedrooms or bathrooms under a small flat rooflight, where a night of rain on the old sheet could be enough to keep someone awake.
A laminated inner pane is also what Part K expects of overhead glazing in most homes, because if the glass is ever broken it stays in place rather than falling into the room. So the specification that makes the room safer is the same one that makes it quieter.
Wind noise changes too. Loose polycarbonate sheets can rattle or creak in their glazing bars as they expand and contract with the temperature, which is often heard as a tick or a creak on a sunny afternoon. A glass rooflight bedded on a proper kerb with gaskets does not move in the same way.
Comparing the old sheet with the new unit
The table sets out the differences between a typical aged polycarbonate rooflight and a modern double glazed replacement. Figures vary by product, so treat it as a guide to direction rather than a specification.
| Aspect | Aged polycarbonate | Glass replacement |
|---|---|---|
| Light colour | Yellow or amber cast | Neutral, true colour |
| Clarity | Hazy, diffuse | Clear, or satin if chosen |
| Thermal | Often poor | Meets Part L |
| Rain noise | Loud drumming | Much quieter |
| Weight | Very light | Heavy, needs a sound kerb |
| Surface life | UV layer wears out | Glass does not yellow |
The weight row is the one that shapes the job. Glass is far heavier than the plastic it replaces, so the roof around the opening needs to carry it, and the kerb or glazing bars need to be designed for it. That is where the installation work goes.
What the replacement involves on the roof
The route depends on what the polycarbonate is sitting in. A flat sheet on a timber kerb can often become a flat glass rooflight on a rebuilt upstand; a multiwall lean-to roof usually becomes either a new glazed roof built for glass or a solid roof with a rooflight or lantern set into it.
Flat and domed rooflights on a kerb. The existing kerb is checked for size, level, rot and height. Modern flat roof guidance looks for an upstand of at least 150mm above the finished roof surface, and a flat glass unit wants a fall of around 5 degrees so rain runs off; many older kerbs were built lower and level. The usual answer is to build up or replace the upstand, fit a pre-angled kerb if needed, and dress the roof covering up and over it so the new unit sits on a properly weathered base. The guide to replacing an old flat rooflight covers the upstand options in detail.
Multiwall lean-to and conservatory roofs. Glass cannot simply be dropped into bars designed for polycarbonate. The bars, their spacing and the rafters beneath were sized for a sheet weighing a few kilograms per square metre. There are two sound routes. One is a new glazed roof system engineered for sealed glass units, on a structure checked or strengthened to carry them. The other, often the better choice for year-round comfort, is a solid insulated roof with a rooflight or roof lantern set where the light is most wanted. That second route is covered in the guide to replacing a conservatory roof with a lantern.
Size. You do not have to keep the old opening. Going larger means trimming the roof structure, going smaller means infilling and insulating around the new kerb; the survey weighs up which suits the room.
If the flat roof covering around the rooflight is itself near the end of its life, it makes sense to do both together so the new upstand is dressed into a new membrane in one visit. Replacing rooflights alongside a new roof is covered in the guide to replacing rooflights during a reroof.
Choosing the glass for your roof
The right glass follows from which way the roof faces and how the room is used, not from a default. On a polycarbonate replacement the choice matters more than usual, because the room has been living under diffused, dimmed light and the new unit will change its character.
A few pairings work well in Cambridge homes. For a north-facing slope or a shaded side return between two terraces, clear double glazing with a standard low-E coating gives the most light and the soft, steady quality that north light has anyway; there is little direct sun to manage. For a flat-roofed kitchen extension that sees the sun from late morning, a solar control outer pane with a neutral tint keeps the heat down without turning the light blue or grey, and a laminated inner pane handles safety and rain noise. For a bathroom or a room overlooked by a neighbour's upstairs window, a satin or obscure inner pane gives privacy and keeps the even, diffuse light the old polycarbonate provided, without the yellow. For a south-facing lean-to used as a dining space, a low g-value coating with an integral or fitted blind gives the most comfortable result through the summer.
Self-cleaning outer coatings are worth considering on a shallow flat rooflight, where dust and pollen from nearby trees would otherwise sit on the glass. Triple glazing makes sense where the room is heated well into the evening and the rooflight is large, though it adds weight and slightly reduces light transmission, so it is a balance rather than an automatic upgrade.
These choices go into the written light plan that comes with every quote, with a line explaining why each was picked for your roof. You can see the thinking behind them before we visit in our published light planning notes.
Building Control, planning and the old sheet
Replacing a polycarbonate rooflight with a glass one is generally treated as replacement roof glazing, and the new unit has to meet current Building Regulations. Where the work is notifiable, we handle the Building Control notification.
Two parts of the regulations matter most for this swap. Part L sets the thermal standard the new unit must meet, and Part K covers safety of overhead glazing, which is one reason laminated inner panes are the norm. Where the structure is being changed to carry heavier glass or to enlarge the opening, Part A (structure) also comes into play, and the Building Control route may be a full application rather than a simple notification. The guide to Building Control for replacement rooflights explains when replacement becomes notifiable and how that is handled.
On planning, a like-for-like replacement of a rooflight in a house usually needs no permission. Changing a lean-to from polycarbonate to a solid roof, enlarging an opening, or raising a unit more than 150mm above the roof plane can change that, and conservation areas, listed buildings and flats have their own rules. Greater Cambridge Shared Planning covers both Cambridge City and South Cambridgeshire, and its constraints map shows whether your street sits in one of the conservation areas. If there is any doubt, we check before anything is ordered.
The old polycarbonate itself is taken away at the end of the job, along with any old glazing bars and timber. The answer on what happens to the old rooflight explains removal and disposal.
Questions people ask
Can I just fit new polycarbonate instead of glass?
You can fit fresh multiwall sheet into existing bars, and it will be clearer for a while, but it will follow the same path of yellowing and loss of UV protection over the years, with the same rain noise and a thermal performance that often falls short of Part L. Glass costs more at the outset and gives a clearer, quieter and warmer result that does not discolour.
Will the new glass rooflight be heavier than my roof can take?
It will be much heavier than the sheet it replaces, which is why the structure is assessed at the survey. A flat rooflight on a sound timber kerb is often straightforward. A lean-to built for lightweight sheeting usually needs a new roof system or a solid roof with a rooflight set into it.
Is the room going to get too hot once the yellow sheet has gone?
It can, on a south or west roof, if the glass is chosen for clarity alone. Specifying a solar control coating and planning for a blind keeps the daylight gain without the summer overheating. On north-facing and shaded roofs, clear glass rarely causes heat problems.
How long does the swap take?
A single flat rooflight on an existing kerb is typically a one-day job, including making good inside. Rebuilding an upstand, or replacing a whole lean-to roof, runs to several days. The timing for your roof is set out in the quote. When you are ready, book a light survey or read more on the misted and failed rooflight replacement service page.