What changes when an old flat rooflight comes out
A flat rooflight replacement takes out the whole unit, glass and frame together, and sets a current one on the upstand below it, either the upstand that is already there or a new one built to suit the better rooflight.
That second choice is the heart of the job, and it is the one people rarely hear about. The glass is what you look at from the kitchen, so it gets the attention. But a flat rooflight is really three things stacked on each other: the roof deck with its opening, the upstand (or kerb) that lifts the glass clear of standing water, and the rooflight itself sitting on top. When an older flat skylight has reached the end of its life, the question is how far down that stack the replacement should go.
In Cambridge the old units come in every shape. There are aluminium framed rooflights from the early 2000s on side-return extensions in Romsey and Petersfield, with sealed units that have misted and frames that stay cold all winter. There are timber kerbs on 1970s flat-roofed kitchen extensions in Cherry Hinton and Arbury carrying units that were never insulated. And there are newer homes in Trumpington and Great Kneighton where the original rooflight is sound in its structure but gives the room more heat and glare than the owners want to live with. Each of them is a flat rooflight replacement, and each leads to a different answer at the upstand.
This guide follows the replacement from the top down: what the new unit offers, what the upstand has to be, how the roof covering is joined back up, and what the room gains. If you are still deciding whether new glass in the old frame would do, read glass only or full unit replacement first. The wider service, including how the survey runs, is on the misted and failed rooflight replacement page.
Reading the old upstand before anything is ordered
The upstand decides the replacement, so it is measured and judged at the survey before a new unit is specified.
Four things are checked. The first is height. Current guidance from the flat roofing bodies asks for an upstand that finishes at least 150mm above the finished roof surface, so that rain pooling on the roof and snow sitting against the kerb cannot reach the joint under the rooflight. Plenty of older kerbs were built lower, sometimes only 75mm or 100mm above the felt, and a roof that has been overlaid once or twice since has crept up the kerb and made it lower still.
The second is fall. A flat rooflight needs its glass to shed water, and the usual way is a slight slope, commonly at least 5 degrees, built into the kerb or into the rooflight frame. An old kerb built dead level under a unit that relied on a domed or pitched top will leave a flat glass unit holding puddles, which dry into rings of grime across the view.
The third is construction and condition. Most older kerbs are timber: a box of treated softwood fixed to the joists and wrapped in the roof covering. The survey looks for softened timber at the corners, for movement where the kerb meets the deck, and for whether the kerb was ever insulated. An uninsulated timber kerb is a cold bridge right at the edge of the opening, and it is often the reason the plaster around an old flat skylight shows dark lines or mould in winter.
The fourth is size. The new rooflight has to sit on the kerb with the right overlap on every side. Manufacturers size their flat rooflights to the internal kerb dimension, so the measurement that matters is the inside of the upstand, not the old glass. Where the old kerb sits between standard sizes, the choice is between a made-to-measure unit and adjusting the kerb.
- Joists, with doubled trimmers either side of the opening to carry the loads of the cut joists around it.
- Deck (usually 18mm ply or OSB) with a vapour control layer laid on it.
- Insulation boards above the deck (a warm roof), often tapered to give the roof its falls.
- Waterproof membrane dressed up the upstand and over its top, so the joint is lapped, not sealed.
- Upstand, or kerb: insulated timber, finishing at least 150mm above the finished roof surface to keep standing water and splash off the joint.
- Rooflight unit fixed over the kerb, its frame skirt shedding water outside the membrane turn-up.
- Plastered reveal lining the opening from the ceiling up to the frame, finished white to bounce the light down.
- Roof falls to an outlet: designed at about 1:40 so the finished roof never falls less than 1:80.

Three routes: reuse, raise or rebuild the upstand
Once the upstand has been read, the replacement falls into one of three routes, and the light plan in your quote says which one and why.
| Route | When it suits | What changes |
|---|---|---|
| Reuse the upstand | Sound, insulated, tall enough, right size | Unit only; roof trim renewed |
| Raise and insulate | Sound timber, but low or cold | Kerb built up and lined; covering dressed up |
| Rebuild the upstand | Soft timber, wrong size or wrong place | New kerb, new trimming, new covering around it |
Reusing the upstand is the lightest touch. The old unit is unscrewed or cut free, the top of the kerb is cleaned and checked for level and fall, and the new rooflight goes straight on. It suits a kerb that was built properly in the first place, which is more common on extensions from the last fifteen years.
Raising the upstand is the middle route and often the best value. The existing timber stays, a new section is added on top to bring the height to 150mm or more above the finished roof, and insulation is fixed to the kerb faces so the edge of the opening is no longer cold. The roof covering is then taken up the new height and finished under the rooflight. From inside the room, the light well becomes a little deeper, which makes a small difference to how the light spreads: a deeper, lined well gives a slightly softer edge to the sun patch on the floor.
Rebuilding means taking the kerb back to the joists and starting again. It is the right call when the timber is no longer sound, when the new rooflight is a different size, or when the opening is going to move. Moving a rooflight is a larger subject with its own guide, repositioning a rooflight when replacing it, but it starts from the same point: a new upstand built where the light is wanted.
Choosing the new flat skylight for the room below
A like-for-like shape does not mean a like-for-like product: the unit going on the upstand can be chosen for the light, heat and use of the room, not simply to match the one coming off.
The first decision is framed or frameless. A framed unit has an aluminium frame around the glass, usually thermally broken, with drainage built into its edge. A frameless or minimal-frame unit bonds the glass to a hidden frame so that from the room you see sky right to the edge of the opening. On a narrow side-return in a terrace, where the rooflight might only be 600mm or 700mm wide, the slimmer edge can add a noticeable strip of glass. On a wide kitchen opening the difference is smaller and the framed unit's drainage detail may be the better trade.
The second decision is fixed or opening. A fixed rooflight is simplest and seals best, but it cannot let out the warm, damp air that collects at ceiling level in a kitchen or bathroom. An opening unit, usually electric with a rain sensor that closes it when the first drops land, lets the room purge heat on a July evening. Replacement is the easiest moment to make that change, because the upstand is exposed and a cable route can be planned before the ceiling is made good.
The third decision is the glass, and this is where orientation comes in, even on a flat roof. A flat rooflight sees the whole sky, so it receives the high summer sun at midday and very little in December. That makes it bright and even for much of the year, but it also means a clear pane over a south-facing garden room can turn the room into a heat trap on a still afternoon. Solar control glass with a lower g-value, a self-cleaning outer pane, and a laminated inner pane for safety overhead are the usual specification. Triple glazing is available on many units and suits bedrooms and rooms that are used on winter evenings. The light planning page explains how we weigh these choices against the room.
Joining the roof covering back to the new upstand
Whatever route the upstand takes, the roof covering has to be dressed up the kerb and finished under the new unit, and that detail decides how the replacement weathers for the next twenty years.
Older flat roofs in Cambridge are covered in a mix of materials: built-up felt on 1970s and 1980s extensions, EPDM rubber and single-ply membranes on newer ones, GRP fibreglass on many kitchen extensions from the 2000s, and lead or zinc on some period houses and higher-end work. Each one is taken up the upstand in its own way. Felt is lapped and torched in layers; EPDM and single-ply are bonded and trimmed; GRP is laid up with a matching resin and topcoat; lead is dressed and fixed at the head.
On a reuse route, the existing covering is often left in place up the kerb and the new rooflight's own trim or flashing kit covers the top edge. On a raise or rebuild route, the covering has to be extended or renewed around the kerb, and it is joined to the surrounding roof with a detail made in the same system. That joint is the one to ask about when you compare quotes. If the rest of the roof is near the end of its life too, it may make more sense to replace the rooflight and the covering together, which is covered in replacing rooflights during a reroof.
Access for this work depends on the height of the roof. A single-storey rear extension can usually be reached with ladders and roof edge protection, while a flat roof at first-floor level or above needs a tower or scaffold. The answer page on whether replacing a rooflight needs scaffolding sets out the options by roof type.
Inside the room: the reveal, the plaster and the light
From inside, a well-planned flat rooflight replacement changes the view up and the light across the floor, while leaving the ceiling around the opening largely as it was.
The reveal is the lined box between the ceiling and the underside of the rooflight. On a reuse route it is often untouched except for a new seal and a fresh coat of paint where the old frame met the plaster. On a raise or rebuild route the reveal gets deeper or is lined again, and the plaster edge is made good afterwards. Our answer on whether replacing a rooflight will damage your ceiling goes into what is protected, what is disturbed and how it is finished.
The light is where the gain shows. An old flat skylight with a misted or clouded sealed unit scatters light into a grey haze and loses the view of the sky. Clear new glass restores the edge of the sun patch, so you can see it move across the worktop through the morning. Slimmer frames add glass area inside the same kerb. The one change that can work the other way is solar control glass, which trims visible light a little as it cuts heat; on a north-facing or well-shaded room a clearer glass may be the better choice. The answer on whether a new rooflight will be brighter than the old one explains the balance.
It is also worth deciding on blinds now. Many flat rooflights take an integral or fitted blind that sits inside the reveal, and the reveal depth after the replacement affects which type fits. Planning the blind with the unit avoids a second visit.
Regulations that shape a flat rooflight replacement
A replacement flat rooflight has to meet current Building Regulations for thermal performance and safety, and where the work is notifiable we handle the Building Control notification.
Under Part L, a new rooflight fitted to an existing home should meet the current limiting U-value, which for rooflights is 2.2 W/m2K, now measured in the horizontal position that a flat rooflight actually sits in. Almost any good modern double-glazed flat rooflight meets that comfortably, and many are well below it. Part K asks for glazing overhead to be safe if it breaks, which is why a laminated inner pane is the normal specification. Part B matters if the rooflight sits close to a boundary or a party wall: rooflights should not sit within 1500mm either side of a party wall on a terrace or semi, which occasionally shapes where a rebuilt upstand can go on a narrow Cambridge terrace.
Whether the work is notifiable depends on what is being changed. A straight swap on the same upstand is treated differently from a new or enlarged opening that alters the roof structure. Our guide to Building Control for replacement rooflights sets out how the notification works and what it covers.
Planning permission is rarely needed for a like-for-like replacement on a flat roof, and a flat rooflight on a rear extension is usually out of public view. The points to check are a conservation area with an Article 4 direction, a listed building, or a flat or maisonette, where permitted development rights do not apply in the same way. Greater Cambridge Shared Planning's constraints map will show whether your address sits in one of the city's conservation areas.
How the replacement day runs
With the upstand route, unit and glass agreed in writing beforehand, a flat rooflight replacement on a single-storey extension is normally a one-day job, with a second day where the upstand is rebuilt.
- The room below is cleared under the opening and protected with dust sheets, and the reveal is masked off.
- Access and edge protection go up, and the new rooflight is checked against the kerb dimensions before the old one is touched.
- The old unit is released from the upstand, lifted off and lowered down. A temporary cover goes over the opening if any time passes before the new unit is set.
- The upstand is cleaned, reused, raised or rebuilt according to the plan, and insulated where it needs to be.
- The roof covering is dressed up the kerb and finished in the same system as the surrounding roof.
- The new rooflight is bedded, fixed and trimmed, and any electric opener or blind is connected and tested.
- Inside, the reveal seal is finished, any disturbed plaster is made good, and the room is cleaned.
The old unit leaves with us. Glass and aluminium can be separated and recycled; the answer on what happens to the old rooflight explains how. The 10-year workmanship guarantee then covers the installation work, with the manufacturer's own warranty covering the product. For a sense of what moves the price, from upstand work to glass choice to access, see the costs page, and when you are ready, book a light survey so the upstand can be read and the light planned before anything is ordered.
Questions people ask
Can a new flat rooflight go on my existing upstand?
Often, yes, if the upstand is sound, insulated, at least 150mm above the finished roof and sized to suit a current unit. Where it is low or cold it can usually be raised and lined rather than rebuilt, which keeps the ceiling opening where it is.
Does the replacement have to be the same size as the old skylight?
No. Keeping the size is simplest because the upstand and ceiling opening stay put, but going larger or smaller is possible with a rebuilt upstand. The answer on whether a replacement rooflight has to be the same size covers what each option involves.
Can I swap an old plastic dome for flat glass?
Yes, and it is one of the most common upgrades on older flat roofs. A flat glass unit usually needs a kerb with a built-in fall, so the upstand is normally adjusted at the same time. The guide to replacing dome rooflights covers that change in detail.
Will the room be warmer in winter after the replacement?
It should be noticeably more comfortable. A current unit with a thermally broken frame, low-E glass and an insulated upstand loses far less heat at the edge of the opening than an older single or early double-glazed flat skylight, and the cold drop of air under the opening is much reduced.