Question

How do I know what skylight I have?

The short answer

Open the sash and look at the top of the frame: a pitched roof window usually carries a data plate or label there with the maker, type and a size code, such as MK04 on a VELUX. No label, or a flat rooflight? Measure the frame and the kerb it sits on, note the glazing and how it opens, and photograph the lot.

Start with the data plate on a roof window

A pitched roof window is the easiest skylight to identify, because the larger makers put a plate or sticker on the frame that names the product.

On a VELUX window, open the sash as far as it goes. On a centre pivot window you tip the glass round until it is out of the way; on a top hung window you push it out from the bottom. The plate sits on the top part of the outer frame, facing into the room once the sash has moved. Older windows tend to have a small stamped metal plate, newer ones a printed label. Other makers, FAKRO and Keylite among them, also label their frames, but where the label sits and what the string of letters means is specific to each maker, so read it against that maker's own guidance rather than VELUX's.

If the frame has been painted over a few times in a loft bedroom, the plate may be under emulsion. A gentle wipe with a damp cloth sometimes brings the lettering back. Do not scrape it. And photograph it the moment you find it, so you are not going back up the ladder later.

Reading a VELUX size code

The current VELUX code is a letter, a K and two digits: the letter gives the width and the digits give the height, measured across the outside of the frame.

So MK04 is 78 x 98 cm and CK02 is 55 x 78 cm. The same size code is used for blinds and flashings, which is why it matters so much when you order anything for an existing window. Alongside the size you will usually see a type code, such as GGL or GGU for a centre pivot window or GPL for a top hung one, with further letters or numbers for the glazing and the generation of window.

Size codeOuter frame (w x h)Typical place
CK0255 x 78 cmSmall loft, landing, bathroom
CK0455 x 98 cmNarrow rafters, stairwell
MK0478 x 98 cmLoft bedroom, study
MK0878 x 140 cmLarger loft room

Older VELUX windows used different formats, such as a letter and two digits, or three digits on the oldest windows. Those translate to modern sizes, though not always one to one, and windows made before around 2001 sit at a different depth in the roof and need a specific replacement flashing. The VELUX window installation page explains how older windows are handled when they are changed.

Identifying a flat rooflight

Flat rooflights rarely carry a readable plate you can reach, so the useful facts come from a tape measure and a close look at how the unit sits on the roof.

From inside, measure the clear opening in the ceiling: width and length, from finished plaster to finished plaster. Then, if you can do it safely from a window or a secure ladder, look at the kerb or upstand the rooflight sits on. Is it a timber kerb built by the roofer, or a factory upstand that is part of the product? Many flat rooflights are sized to the inside of the kerb, but some makers quote the outside of the frame, and the two can differ by several centimetres. That is maker-specific, so write down both if you can, and never climb onto a flat roof to get them.

Then note what you are looking at:

  • glass or plastic: a flat sheet of glass, a raised dome or a polycarbonate panel
  • fixed or opening, and if opening, manual or electric
  • a slim frameless edge or a visible aluminium or uPVC frame
  • any etched mark in a corner of the glass, which can name the glazing maker or the date

Lanterns, sun tunnels and conservation windows

These three are identified more by their form than by a code, and the details that matter are the ones that change the replacement.

For a roof lantern, measure the upstand it sits on and count the glazing bars on each side. Note whether the frame is aluminium or uPVC and whether there is a ridge vent. For a sun tunnel, the size is the diameter of the tube, which you can read off the ceiling diffuser. For a conservation roof window, look for the slim profile and the central glazing bar, then check the frame for a plate in the same place as an ordinary roof window. If you are not sure which of these you have, the explainer on the difference between a rooflight, skylight and roof window and the guide to types of rooflight will help you name it.

Why the details matter when you replace it

Knowing what you have tells you whether a like for like swap is simple, whether the flashing and lining can stay, and what choices you have for the light.

A standard size code means a matching new roof window can often go into the same opening. A flat rooflight on a sound kerb of known size can usually be renewed without disturbing the roof around it. But the old unit is only the start. If a loft room overheats in summer under a south or west slope, or the sun patch lands on a desk or a TV screen, the replacement is the moment to change the glass, the blind or even the size. Our guide to skylight replacement options sets out those choices, and replacing a skylight with a bigger one covers enlarging the opening. If the glass has misted between the panes, the page on misted and failed rooflight replacement explains why the whole unit is usually renewed.

If you cannot find a plate, or the codes do not match anything, that is fine. At a light survey we read what is there, measure the opening and the kerb, look at the slope's orientation and set out the recommended skylight, glass and shading in the written light plan that comes with the quote. You can book a light survey, or send photographs of the plate and the frame when you message us on WhatsApp. More on how we work is on our skylight and rooflight installation in Cambridge homepage.

Questions people also ask

Where is the size code on a VELUX window?

Open the sash fully and look at the top of the outer frame. The plate or label faces into the room and carries the type code and size code, such as GGL MK04. On some older windows the plate is small and may be painted over.

Can I tell the size of a skylight from inside?

You can measure the opening in the ceiling, but that is the lining, not the window. A roof window size code refers to the outside of the frame, so the ceiling opening only gives you a guide. For a flat rooflight, note the ceiling opening and, where it is safe to see it, the kerb size.

What if my rooflight has no label at all?

Photograph the frame, the glass, the opener and the view from outside if you can, and measure what you can reach. An installer can usually match it to a current product, or specify a new one for the opening, at a survey.

Does the make matter if I am changing to a different brand?

It helps. The existing make and size tell the installer the opening, the flashing depth and how the lining was formed, which decides how much making good the change involves. The guide to the rooflight replacement process explains the stages.

Book a light survey

Tell us about the room

  • No obligation
  • Light plan in writing
  • 10-year guarantee
Book a survey Call