Guide · Misted and failed rooflight replacement

Replacing a Failed Roof Lantern

A worn roof lantern is a chance to fit a better one. This guide explains when a new lantern can sit on the existing upstand, when the kerb should be rebuilt, and how to choose glass for the light you want.

13 min read10 chapters

When a lantern has reached the end of its life

A roof lantern is due for replacement when its glass, its frame or the kerb it sits on can no longer give the room clear, warm, dry light, and roof lantern replacement is the chance to fit a better unit than the one that came with the extension.

Lanterns age in a recognisable way. The sealed units mist between the panes, one after another, until the view of the sky turns milky. Older uPVC lanterns from the 1990s and early 2000s develop sagging hip bars and gaps at the ridge where the cappings have moved. Polycarbonate lanterns yellow, go brittle and drum loudly in rain. Inside, condensation runs down cold glazing bars and marks the plaster on the upstand reveal. None of this is sudden, which is why many owners live with it for years before deciding the room deserves better.

The question this guide answers is how the replacement should be done. There are two routes. The first keeps the existing upstand and sets a new lantern on it, which is quick and keeps the internal ceiling untouched. The second takes the upstand down to the roof deck and builds a new kerb, which costs more time but lets you change the height, the size and sometimes the position, and replaces the weaknesses a tired kerb hides with a sound, insulated base. Choosing between them is mostly about the condition and the dimensions of what is already there, and about what you want the room to feel like afterwards.

If only one pane has failed on an otherwise sound lantern, a single pane swap may be enough, and our answer on replacing a single roof lantern glass panel covers that case. This guide is about renewing the whole lantern skylight.

Reading the upstand before anything is ordered

The upstand decides the route, so the survey looks at it first, from the roof and from the room, before a single lantern size is written down.

Most lanterns in Cambridge extensions sit on a timber kerb built up from the flat roof deck, with the roof covering dressed up its outer face and the plasterboard reveal lining its inner face. The lantern frame sits on top and is fixed down through a base plate or a timber sole. When the kerb is sound, square and high enough, it can carry a new lantern for decades. When it is not, a new lantern on it inherits every fault.

At the survey these are the things that are checked:

  • Height above the finished roof. Current guidance for flat roof glazing looks for an upstand of at least 150mm above the finished roof surface, so that standing water and driven rain stay below the frame. Plenty of older kerbs were built lower, and a new roof covering laid over the old one reduces the height further.
  • Square and level. A new lantern is made to a fixed size. If the kerb is out of square by more than a small tolerance, or twists along its length, the frame will not bed evenly and the glass units carry stress they were not designed for.
  • Condition of the timber. Softness at the corners or along the lowest side, where water has sat against the covering, shows up when the old lantern comes off. It is better to plan for it than to discover it on the day.
  • Insulation. Many older kerbs are bare timber with nothing behind the reveal. That cold strip around the opening is where condensation forms, and it is one of the reasons the old lantern felt chilly on winter mornings.
  • The roof covering around it. Felt, single ply membrane or GRP has to be sound where it meets the kerb. If the whole flat roof is near the end of its life, the lantern and the covering are best renewed together, as our guide to replacing rooflights during a reroof explains.

Some of these can only be confirmed once the old lantern is lifted, so the written quote says plainly what is assumed and what would change the plan.

Three-quarter view of an aluminium roof lantern on a flat roof, showing the ridge, hip bars, glazing bars, glass panels, eaves beam with its drip line, and the upstand.1234567
Fig. Anatomy of an aluminium roof lantern on a flat roof.
  1. Ridge: the spine where the slopes meet, usually with an end cap or finial.
  2. Hip bars run from each corner to the ends of the ridge and carry the most load.
  3. Glazing bars hold the glass on each slope. Slimmer bars mean more glass and more light.
  4. Glass panels: sealed units, usually with a solar-control coating, since a lantern takes sun from every side.
  5. Eaves beam: the perimeter frame the whole roof sits on, carrying the rafters and often housing a thermal break.
  6. Gutter and drip line: rain runs down the glass, into the eaves beam and off a drip edge clear of the upstand.
  7. Upstand: the insulated kerb that lifts the lantern clear of the flat roof, with the roof membrane dressed up it.

Route one: a new lantern on the existing upstand

Keeping the upstand works well when the kerb is at least 150mm clear of the roof, square, dry and insulated, and when the size of the opening already suits the room.

This is the lighter job. The old lantern is unscrewed from the kerb and lifted off in pieces or as a whole, the top of the kerb is cleaned and checked, and the new lantern is bedded and fixed in its place. The roof covering is disturbed only along its top edge, where the new frame and its trims overlap it. Inside, the ceiling and the reveal usually stay as they are, apart from a decorated line where the new frame meets the old plaster.

The lantern is ordered to the external dimensions of the kerb, which is why accurate measuring matters so much. Lantern manufacturers size their units to the outside of the upstand, and the frame is designed to overhang it slightly so that water runs off clear of the joint. A kerb that measures 2,000 by 1,500mm on one side and 1,985mm on the other needs attention before the order goes in, not after the lantern arrives.

The benefit of this route is speed and minimal disruption. The limit is that everything about the opening stays as it was: the same footprint of light, in the same place, at the same height above the roof. If the old lantern always felt slightly too small for the kitchen, or sat over the wrong end of it, keeping the upstand keeps those decisions.

Route two: rebuilding the upstand for a better unit

Rebuilding the kerb is the right call when the existing one is low, rotten, out of square or uninsulated, or when the new lantern should be larger, longer or better proportioned than the old one.

The work goes further down. After the old lantern is removed, the timber kerb is cut away to the roof deck, the edges of the roof covering are lifted back, and a new kerb is built from treated timber to the new size and height. Insulation goes into or behind the kerb so that the reveal is no longer the coldest surface in the room. The roof covering is then dressed up the new upstand and sealed, and the new lantern is set on top. Inside, the reveal is lined, plastered and made good.

A new upstand is also the moment to reconsider the size. The general rule of thumb in the trade is a lantern covering somewhere around 15 to 20 percent of the flat roof it sits in, with higher ceilings able to carry a larger unit without the room feeling like a glasshouse. An old lantern that was fitted to whatever the builder had in stock is often narrower than the room would like. Where the opening changes size, the joists around it have to be trimmed to suit, and that becomes a structural question for the survey and, where needed, an engineer.

Moving the lantern along the roof is possible in the same way, though it is a bigger decision: the old opening has to be infilled and insulated, and the new one formed. Our guide to repositioning a rooflight when replacing it looks at when that is worth doing.

Comparing the two routes

The table sets the two routes side by side; the survey fills in which one your roof points towards, and the written quote explains why.

QuestionExisting upstandNew upstand
Kerb height150mm or more, soundLow or worn
Size of lightStays the sameCan change
Roof coveringEdge onlyDressed up new kerb
Inside the roomLight decorationReveal relined
Time on siteOften one dayTwo to three days

The times are a guide for a typical domestic lantern and depend on access, the size of the unit and the weather. A large lantern, an awkward roof or a new opening in the joists takes longer, and the quote says so.

What a modern lantern gives the room

The biggest difference most owners notice is not the brightness but the quality of the light: clearer glass, slimmer bars and a warmer room in both January and July.

Older lanterns, especially uPVC ones, carry wide glazing bars and deep internal cappings. Seen from below they break the sky into narrow strips and cast a grid of shadow across the worktop. A modern aluminium lantern carries the same glass on much slimmer bars, with thermally broken sections so the frame stays warm enough to resist condensation. The ridge is neater, the hips are straighter, and the whole unit reads as a lighter object on the roof.

The glass is where the replacement does the most for how the room feels. A lantern has several slopes facing different directions, so it takes low east light in the morning, high sun at noon and low west light in the evening. On the flat, open ground around Cambridge there is rarely a hill or a tall neighbour to shade it. That makes glass choice the main control over heat and glare:

Solar control glass cuts the heat that reaches the room while letting most of the visible daylight through, which suits kitchens and garden rooms where the lantern faces a lot of open sky. A low emissivity coating keeps warmth in during winter, which matters most on the side of the room where people sit. Self-cleaning outer glass helps on a lantern that is hard to reach, and a laminated inner pane adds safety overhead. Tints are chosen with care, because a strong blue or grey tint changes the colour of the whole room. Whether the new lantern will actually be brighter depends on how much light the old one had lost and on the coating chosen, as our answer on whether a new rooflight will be brighter explains.

On thermal performance, a replacement rooflight should meet the current Part L limit, which for rooflights is a U-value of 2.2 W/m2K measured in the horizontal plane. Good double glazed lanterns reach this comfortably, and triple glazed lanterns go further. Our light planning page shows how orientation shapes the glass choice for each slope.

Weight, structure and the move from plastic to glass

Where the old lantern was polycarbonate, the new glass unit will be heavier, so the roof around the opening has to be checked before a glass lantern is specified.

A polycarbonate lantern weighs little, and some were fitted onto lightweight kerbs and joists that were never designed for glass. A double glazed aluminium lantern of the same size is considerably heavier, and a triple glazed one heavier again. On most modern extensions the trimmed joists around the opening carry this comfortably, but on older ones, or on conversions where a conservatory roof was replaced with a flat roof and lantern, it needs to be confirmed. The survey looks at the joist size, span and trimming, and where there is any doubt an engineer checks it before the order goes in. The same applies when the opening grows.

The gains from leaving plastic behind are large: a quieter room in rain, far less heat loss, no yellowing and a clear view of the sky. Our guide on replacing polycarbonate rooflights covers those gains in more detail. Where an entire glazed conservatory roof is the problem rather than a lantern, see replacing a conservatory roof with a lantern.

Planning, Building Control and the paperwork

A like-for-like lantern replacement rarely raises a planning question, but a taller, larger or relocated lantern can, and the Building Regulations apply to the new unit either way.

On planning, replacing a lantern with one of similar size and height on a rear extension is generally treated as a like-for-like change. Where a new lantern would sit noticeably higher, the permitted development rules for rooflights added to an existing roof limit projection to 150mm above the roof plane, and a raised kerb plus a taller lantern can push past that. Listed buildings, conservation areas and homes covered by an Article 4 direction are more sensitive. Greater Cambridge Shared Planning covers the city and South Cambridgeshire, and the details of any particular house are worth checking with them before committing to a bigger change.

On Building Regulations, the new lantern must meet Part L for heat loss and, as overhead glazing, needs safety glass on the inner pane. Where the replacement is notifiable, we handle the Building Control notification as part of the job; our guide to Building Control for replacement rooflights explains when that applies and what the notification involves. Any change to the joists around the opening brings in the structural side of the regulations too.

How the day unfolds

Lantern replacement is planned so that the roof is open for as short a time as possible, with the new lantern on site and checked before the old one comes off.

The weather forecast is watched in the days before. On the morning, the room below is cleared and the floor and worktops covered. Access is set up: for a single storey extension this is usually a tower or ladders with edge protection, and for larger or higher lanterns a scaffold or a lifting aid. Our answer on whether replacing a rooflight needs scaffolding goes into the options.

  1. The glass is taken out of the old lantern first, pane by pane, to make the frame light and safe to lift.
  2. The frame is unfixed and removed, and the upstand is inspected with the lantern off.
  3. On the existing upstand route, the kerb top is prepared; on the rebuild route, the new kerb is built, insulated and the roof covering dressed up it.
  4. The new lantern frame is assembled and fixed, the glass units are set in, and the ridge and hip cappings go on.
  5. Inside, the reveal is made good and the old lantern is taken away for disposal and glass recycling.

If the job runs over a day, the opening is covered and made weathertight overnight. Inside, the disturbance is usually confined to the reveal and a narrow band of ceiling around it, which is explained in our answer on whether replacing a rooflight will damage the ceiling.

Questions people ask

These are the points that come up most when a lantern skylight replacement is being planned.

Can I keep my old lantern blinds?

Rarely. Lantern blinds are made to the exact glass sizes and bar positions of one lantern, and a new unit will differ. Plan new blinds at the same time, and consider that solar control glass may reduce how much you need them.

Will the new lantern look the same from the garden?

It can be close in outline, but modern aluminium lanterns are usually slimmer and lower in profile at the ridge. If the kerb is rebuilt higher, the lantern will sit a little taller on the roof.

Can I change the colour of the frame?

Yes. Aluminium lanterns are powder coated, commonly in greys, black or white, and many can have a different colour inside and outside. Grey outside and white inside is a popular pairing because it keeps the ceiling bright.

How do I start?

Start with a survey of the lantern and the upstand. You receive a written light plan with the route, the size, the glass and the reasoning, alongside the quote. The misted and failed rooflight replacement service page shows the wider process, and you can book a light survey or message us on WhatsApp.

Book a light survey

Tell us about the room

  • No obligation
  • Light plan in writing
  • 10-year guarantee
Book a survey Call