Guide · Flat roof rooflights

Framed vs Frameless Flat Rooflights

A framed rooflight holds its glass in aluminium; a frameless one bonds the glass so the pane is the top of the unit. Here is what that changes for heat, water, the view from the room and the roof it sits on.

16 min read9 chapters

Two ways of holding the glass

The difference between a framed and a frameless flat rooflight is where the glass stops and what holds it: a framed unit clamps the sealed glass inside an aluminium frame, while a frameless unit bonds the glass to its carrier so the pane itself is the top of the rooflight.

Everything else follows from that one decision. A framed rooflight has a perimeter of metal around the glass on both faces. Outside, a cap or cover strip sits over the glass edge and presses a gasket against it; inside, you see a frame border between the glass and the plastered reveal. The sealed unit sits in a rebate, much like the glass in a good aluminium window, and the frame is what meets the kerb.

A frameless rooflight takes the metal off the top. The sealed unit is bonded, usually with structural silicone, onto a carrier or an insulated upstand, and the outer pane is often stepped: it is cut larger than the inner pane so its edge oversails the kerb and sheds water past it. From outside you see a slab of glass with a thin dark border where the edge seal and the bond sit. From inside you look up at glass running close to the reveal on all four sides.

Both are proper products from serious manufacturers, and both can be fitted to current Building Regulations. The choice is not between a good type and a poor one. It is between two sets of trade-offs in heat loss at the edge, the way water leaves the glass, what you see from the room, and how the unit ages on a Cambridge roof. This guide works through each in turn. If you are still at the stage of deciding whether a flat rooflight is right at all, start with our page on flat roof rooflight installation in Cambridge and come back here when the type is the question.

The trade still uses both words for these units. A builder will say rooflight; a homeowner searching late at night will usually type skylight. The framed vs frameless skylight question and the framed vs frameless rooflight question are the same question, and everything below applies to either name.

Heat at the edge: the thermal break against the bonded seal

The coldest line on any flat rooflight is its edge, and the two types keep that line warm in different ways: the framed unit relies on a thermal break inside the aluminium, the frameless unit on keeping metal out of the path altogether.

Aluminium conducts heat very well. A solid aluminium frame running from the heated room to the winter air outside would act as a cold bridge, and on a still January night the inner face of the frame would drop low enough for condensation to form along it. Framed rooflights deal with this with a thermal break: the frame is made in an inner and an outer section joined by a strip of low-conductivity material, commonly a glass-reinforced polyamide. Heat has to cross that strip, and it crosses it slowly. A well-designed break keeps the inner frame close to room temperature. A poorly designed one, or a unit with no break at all (older rooflights sometimes had none), gives you a cold rim that weeps in winter.

A frameless unit has less metal to worry about. The glass edge sits on an insulated carrier or on the kerb itself, and the path from inside to outside runs through the sealed unit's edge spacer and the silicone bond. With a warm-edge spacer and an insulated upstand below, the edge can perform well. The weak point moves: instead of the thermal break in the frame, it is the junction between the underside of the glass and the top of the kerb, and whether the insulation below is continuous up to that line.

That is why the type of roof matters as much as the type of rooflight. On a warm deck roof, where the insulation sits above the deck, the upstand has to carry that insulation up to the underside of the unit, and the vapour control layer has to be dressed up the kerb as well. Our answer on fitting a rooflight to a warm deck flat roof covers that detail. Get it wrong and neither type will save you: a cold kerb under a frameless pane condenses just as surely as an unbroken aluminium frame.

On paper, compare whole-unit U-values, not centre-pane figures. Part L sets a limiting value of 2.2 W/m²K for a rooflight in an existing home, and under the 2021 edition it is assessed with the rooflight in the horizontal position, which is the honest way to rate a flat unit. A centre-pane figure for a triple-glazed unit can look impressive and say nothing about the frame. Ask for the whole-unit figure measured horizontally, and ask whether the upstand is included. Framed units carry more of their heat loss in the frame; frameless units carry more in the glass and its edge. The glass itself is a separate choice, set out in flat rooflight glazing choices.

Section through a flat-roof rooflight: joists and trimmers, deck, insulation laid to falls, a kerb at least 150mm above the finished roof with the membrane dressed over it, the rooflight unit and a plastered reveal.150mm1:4012345678
Fig. Section through a flat-roof rooflight on a warm-deck roof, drawn at about 1:20.
  1. Joists, with doubled trimmers either side of the opening to carry the loads of the cut joists around it.
  2. Deck (usually 18mm ply or OSB) with a vapour control layer laid on it.
  3. Insulation boards above the deck (a warm roof), often tapered to give the roof its falls.
  4. Waterproof membrane dressed up the upstand and over its top, so the joint is lapped, not sealed.
  5. Upstand, or kerb: insulated timber, finishing at least 150mm above the finished roof surface to keep standing water and splash off the joint.
  6. Rooflight unit fixed over the kerb, its frame skirt shedding water outside the membrane turn-up.
  7. Plastered reveal lining the opening from the ceiling up to the frame, finished white to bounce the light down.
  8. Roof falls to an outlet: designed at about 1:40 so the finished roof never falls less than 1:80.

Where the water goes: drainage paths and falls

A framed rooflight is designed to let a little water in and lead it out again; a frameless rooflight is designed to shed water before it ever reaches a joint, so the fall on the glass matters even more.

In a framed unit, the outer gasket is the first line of defence and not the only one. Any rain driven past it lands in a drained channel inside the frame and runs out through small weep slots on the low side. This is the same thinking as a well-made aluminium window. It tolerates a small amount of imperfection, and it tolerates the gasket ageing, because the drained cavity catches what gets past.

The price of that frame is a lip. On a shallow fall, the lower edge of the frame stands slightly proud of the glass, and water running down the pane has to climb over it or find its way round. Rain does, but the fine grit it carries can settle against the frame, and that is where the grey tidemark forms along the bottom edge of an older rooflight. Low-profile frames and capless designs reduce the lip. Some framed units build a pitch into the frame itself so the glass sits steeper than the kerb.

A frameless rooflight has no lip. Water runs straight off the stepped edge of the outer pane, clears the kerb and drops onto the roof covering. There is no drained cavity, though, and the weather seal is the silicone line at the glass edge. The product relies on that seal and on the fall. This is why frameless makers are usually firm about the minimum slope: somewhere around 5 degrees on the glass is the common figure, and some products ask for it to be built into the kerb rather than supplied by the unit. Our answer on the minimum pitch for a flat rooflight sets out why.

The fall also decides where the water lands. We fall the glass away from the house wall wherever the roof allows, so the run-off heads for the open side of the roof and the outlet, not into the corner where a side-return roof meets the main house. On a parapet roof, or a roof with a single outlet, that choice is made with the roofer before the kerb is built, because the kerb sets the fall.

What you see from the room: sightlines and the edge of the light

From below, a frameless rooflight reads as a clean opening of sky, and a framed one reads as a window in the ceiling; the difference is visible, and it also changes the shape of the light on the floor.

The frame border on a framed unit is typically a few tens of millimetres wide on the inside face, depending on the product and the size. On a small unit that border is a bigger share of the view than on a large one. Stand under a framed rooflight and you see the plastered reveal, then a strip of frame, then the glass. Stand under a frameless one and the reveal runs almost straight to the glass. In a pared-back kitchen with a flush plaster reveal, that is the look people are after, and it is often the reason the architect drew a frameless unit in the first place.

There is a small light gain too. For the same structural opening, a frameless unit usually gives a little more clear glass, because the edge that would have been frame is glass. That is not a dramatic difference in the amount of daylight, and we would never size a rooflight on it. The more useful effect is at the edges of the light. A frame and a deep reveal both cast shadow when the sun is low, and in Cambridge the sun is low for much of the year. At 52 degrees north, the midday sun at the winter solstice stands only about 14 degrees above the horizon, and even at midsummer noon it reaches only about 61 degrees. For months on end, direct sun comes through a flat rooflight at a shallow angle, and anything standing above the glass line, whether frame, upstand or reveal, trims the sun patch on the floor or wall.

Colour matters to the sightline as well. A dark frame reads as a crisp outline against the sky and makes the glass look brighter by contrast; a white frame against a white ceiling almost disappears, which some people prefer to a frameless edge. The answer on frame colours for flat rooflights goes through the options. And depth matters: frameless and framed units have different overall heights, which change how the unit sits on the upstand and how deep the internal reveal ends up. Our answer on how thick a flat rooflight is gives the typical ranges.

Weathering and ageing on a Cambridge roof

Both types age, but in different places: a framed unit ages at its gaskets and powder coat, a frameless unit at its silicone bond and the exposed glass edge.

A flat roof in Cambridge takes a lot of sky. The land is flat, there are few hills to shade anything, and a rooflight on a single-storey rear extension sees sun, frost and rain from every direction the weather comes. Ultraviolet light is the slow enemy of rubber and silicone. On a framed unit the gaskets sit mostly under the cap, shaded from direct sun, and on many products they can be renewed without disturbing the glass. The powder-coated aluminium itself lasts well if the coating is good and the roof is kept clear.

On a frameless unit, the structural silicone is shielded by the ceramic frit or dark border printed on the outer pane, which exists partly to block UV from reaching the bond. That border is doing a real job, so it is worth checking the product has one. The glass edge is exposed, though. The stepped outer pane is toughened or laminated and designed for it, but a slipped ladder or a dropped tool on the roof lands on glass, not on a metal cap. On a flat roof that is walked on for gutter clearing or roof maintenance, that is worth knowing.

Dirt behaves differently too. Tree-lined streets in Newnham and Chesterton drop leaves and seed onto rear extension roofs every autumn. On a framed unit with a lip, the debris gathers along the low edge of the frame. On a frameless unit it slides further, because nothing stops it at the glass edge, and it ends up against the upstand or in the roof outlet. Neither type cleans itself fully at a shallow pitch. A self-cleaning coating helps with fine dirt on both, within limits, as our answer on whether a flat rooflight can be self cleaning explains.

The biggest difference shows up years later, when a sealed unit fails. With many framed products, a misted sealed unit can be taken out of the frame and a new one set in. With a frameless product the glass is the rooflight, bonded to its carrier, so renewing the glass generally means replacing the whole unit. That is not a reason to avoid frameless glass. A good sealed unit should last a long time. It is a reason to buy the frameless product from a maker whose units, sizes and carriers are likely to be available when you need one.

Fitting tolerances: how true the kerb has to be

A framed rooflight forgives a kerb that is a few millimetres out; a frameless one asks for a kerb that is square, level along its length and built to the exact size the unit expects.

This is the practical point that decides a lot of jobs on older Cambridge houses. A framed unit sits on the kerb and its frame spans small irregularities. The frame has some depth to it, the fixings go through the frame into the timber, and the frame's own seal to the kerb can take up a little unevenness. On a 1930s semi with an extension roof that has settled, or on a Victorian terrace in Romsey where the rear roof was built on joists that are no longer quite straight, that forgiveness is useful.

A frameless unit either comes with its own factory upstand, which then needs a flat and level base, or bonds onto a site-built kerb that has to be dead true. Any twist in the kerb puts stress into a bonded pane, and a bonded pane has no frame to absorb it. The upstand also has to be the right height above the finished roof covering: 150mm is the usual minimum, as our guide to flat rooflight upstands explains, and it is measured from the finished roof, not the deck.

New builds are more forgiving of frameless glass than old roofs, simply because the roof is new and flat. On a newer home at Trumpington Meadows or Great Kneighton, where a rear extension may be only a few years old with a single-ply roof in good condition, a frameless unit on a factory upstand is often straightforward. On an older roof that needs its covering renewed around the new opening, the covering is laid first and the kerb checked before the glass arrives. The guide to flat rooflights and roof coverings sets out who does which part.

Size also has limits. Frameless panes get heavy quickly, and the bigger the pane, the more the unit relies on the structural bond and the more handling it needs on the day. Framed systems can be joined with intermediate bars into long runs. Frameless systems join too, with glass-to-glass silicone joints on some products, but they are specified with the maker. Our page on flat rooflight sizes covers the spans.

Side by side

This table puts the four points of difference together, with the caveat that individual products vary and the maker's data for the unit you are buying always wins.

PointFramedFrameless
Edge heatThermal break in the frameInsulated carrier and warm edge
WaterDrained frame, weep slotsSheds off stepped glass edge
Fall neededSome pitch built into frameAround 5 degrees, often in kerb
Inside viewFrame border to revealGlass close to reveal
KerbTolerates small errorsMust be square and true
Failed glassUnit often swapped in frameUsually whole unit replaced

A couple of things are the same for both. Overhead glazing over a room people stand in should have a laminated inner pane, so broken glass stays in place, and both types are made that way for domestic use. Both can be opening units, though the frameless opening options are fewer; the guide to fixed vs opening flat rooflights deals with ventilation. And both need the same Building Regulations thinking about structure, heat loss and fire near a party wall.

Which suits which room and roof

Choose frameless where the look of the ceiling matters most and the roof is new and true; choose framed where the roof is older, the opening is awkward, or you want a unit that can have its glass renewed in the frame.

A few situations are typical of the houses Cambridge has. A kitchen extension on a new-build with a flush plastered ceiling, a single-ply roof in good order and a clear fall away from the house is a natural home for frameless glass. The clean edge suits the room, and the roof gives the kerb what it needs. A side-return extension on a Mill Road terrace, overlooked from the back bedroom window of the house and its neighbours, is a different question. From above, a frameless pane reads as a sheet of glass lying on the roof, and a framed unit looks more like a window. Some owners prefer the first, some the second, and it is worth looking down from upstairs at the space before deciding.

A flat roof dormer on a loft conversion, where the rooflight is small and the ceiling below is often sloped on one side, tends to favour framed units. The border matters less on a small light, the dormer roof is tight to work on, and the frame's tolerance helps. A long garage or garden room roof, where the rooflight is more practical than decorative, is another place where a framed unit makes sense. For a walk-on or a very large single pane, you are into specialist products where the choice is set by the engineer and the maker.

Orientation plays its part in the choice of glass rather than the choice of frame. A frameless pane facing a clear south sky over a kitchen is still a south-facing pane, and it needs the same solar control glass and shading plan as a framed one. What the type does change is the edge of the sun patch, and in a room where you will sit under the light, such as a dining end or a snug, a clean edge to that patch can make the light feel calmer. That is the kind of detail we look at when we plan the light, and it is set out on how we plan the light.

Neither type is the right answer everywhere. What matters is matching the unit to the roof it will sit on and the room it will light, then detailing the kerb, the insulation and the fall properly. If you would like us to look at yours, book a light survey and we will put the recommendation, and the reason for it, in the written light plan that comes with the quote.

Questions people ask

Is a frameless rooflight less likely to let water in?

Not in itself. A frameless unit has fewer joints for water to find and no lip to hold it, but it relies on its silicone seal and a proper fall. A framed unit has more joints but a drained frame behind them. Either, fitted on a correct upstand with the roof covering dressed up properly, keeps water out.

Do frameless rooflights get more condensation?

They should not, if the upstand is insulated and the edge of the glass uses a warm-edge spacer. Condensation at the edge of any flat rooflight usually points to a cold kerb, a missing thermal break or a gap in the insulation line below the unit, rather than to the frame type.

Can I swap an old framed rooflight for a frameless one?

Often, yes. The old unit and usually the kerb come off, a new upstand is built or fitted to suit the frameless product, and the roof covering is renewed around it. Because frameless units ask for a truer kerb and sometimes a steeper fall, the upstand is normally replaced rather than reused.

Is one type more energy efficient than the other?

It depends on the product, not the category. Compare whole-unit U-values measured in the horizontal plane, which is how Part L now assesses rooflights, and check whether the figure includes the upstand. A good framed unit can beat a poor frameless one, and the other way round.

Book a light survey

Tell us about the room

  • No obligation
  • Light plan in writing
  • 10-year guarantee
Book a survey Call