Question

Can a flat rooflight be self cleaning?

The short answer

Yes. A flat rooflight can have self-cleaning glass: a thin coating on the outer pane that breaks down organic grime in daylight and makes rain spread into a sheet that rinses it away. On a flat skylight laid at around 5 degrees, water runs off slowly, so the coating keeps the glass clearer for longer but does not remove the need for an occasional rinse.

What the coating actually does

Self-cleaning glass works in two stages, and both depend on the weather: daylight loosens the dirt, then rain carries it off.

The coating is a microscopically thin layer, usually based on titanium dioxide, on the outside face of the outer pane. In ultraviolet light it acts as a photocatalyst, slowly breaking down organic deposits such as pollen, leaf residue, algae and the greasy film that traffic and wood burners leave on glass. The same layer is hydrophilic: instead of beading into droplets that dry as spots, rainwater flattens into a continuous film across the pane. That film lifts the loosened residue and carries it towards the edge.

On many products the coating is bonded into the glass surface during manufacture rather than sprayed on afterwards, so it is expected to last as long as the sealed unit. It needs a spell of daylight after installation before it starts working at full effect, which is why a newly fitted rooflight can look no different from ordinary glass for its first week or two.

Why a near-flat pane is the hard case

The coating was developed with vertical and steep glass in mind, where gravity pulls the water film off quickly. A flat rooflight gives it far less help.

Flat rooflights are not truly flat. The glass is set at a fall of about 5 degrees, either by a pitched upstand or by the unit itself, so that water drains rather than pooling. Our answer on the minimum pitch for a flat rooflight explains where that figure comes from. At 5 degrees the sheet of rainwater still forms, but it moves slowly, and in light drizzle it can evaporate before it reaches the lower edge. What was dissolved in it is left behind as a faint tide line.

The low edge is where this shows first. On a framed unit, the frame lip at the bottom of the glass can hold back a narrow band of water and fine grit. On a frameless unit, where the glass oversails the kerb, the water leaves the pane cleanly, which is one of the practical differences covered in our guide to framed vs frameless flat rooflights. A steeper fall, from a taller or more sharply angled upstand, also helps; the guide to flat rooflight upstands covers how the kerb sets that angle.

What it clears and what it leaves

The coating is good at organic film and poor at anything heavy, mineral or stuck fast, so the setting of the roof decides how much it can do.

DepositCoating effectWhat helps
Pollen and light grimeBreaks down and rinses wellRegular rain
Tree sap and honeydewSlow, partialOccasional hose rinse
Bird droppingsSoftens over weeksRinse early
Leaves and seed podsNo effectClear by hand
Dust and fine soilLittle effectRain or a rinse

Cambridge adds its own conditions. Gardens in the tree-lined streets of De Freville and Newnham, or backing onto green space, catch lime and sycamore honeydew in summer, a sticky film that the coating deals with only slowly. Fenland villages see fine windblown soil in dry spring weather, which is mineral and so untouched by the photocatalytic reaction. A skylight on a side-return extension tucked against a two-storey rear wall may sit partly in a rain shadow, where the wall intercepts rain driven on a westerly wind and the glass is wetted less often than open roof. None of these makes the coating pointless, but each is worth knowing before you choose it.

What cleaner glass does for the light in the room

The reason to care about dirty rooflight glass is the room below: a grimy horizontal pane softens and greys the daylight long before it looks dirty from the kitchen.

A flat skylight faces the whole sky, which is what makes it such a strong source of daylight on the level ground around Cambridge, but it also faces every falling leaf, bird and shower of pollen. Vertical windows are washed by driving rain; a near-flat pane collects. A film of grime scatters the incoming light, so a sun patch that should have crisp edges on the worktop turns hazy, and on overcast days the room simply feels flatter. Self-cleaning glass slows that drift, which matters most where the rooflight is the only daylight, as in a deep terrace kitchen or a side return.

Looking after self-cleaning glass

Care is simple, but the wrong product can damage the coating, so it is worth knowing the few things to avoid.

In a dry spell, a gentle rinse with clean water from a hose restarts the cleaning cycle, provided the glass can be reached safely from a ladder at the roof edge rather than by standing on the glass or the covering. If something more is needed, use warm water with a small amount of mild washing-up liquid and a soft cloth or squeegee. Avoid abrasive pads, scrapers, razor blades, silicone-based sprays and ordinary glass cleaners with additives, since these can scratch the coating or leave a water-repellent film that stops the sheeting effect. Clear leaves from the roof around the upstand too, so water leaving the glass has somewhere to go. The manufacturer's care sheet for the specific unit takes precedence over any general advice.

Is it worth specifying?

For flat roofs that are hard to reach, the coating is a sensible default; the case weakens where the glass is easy to clean or sits under trees all year.

It earns its place on a rooflight over a two-storey rear extension, a dormer top or a parapet roof, where getting to the glass means a ladder and some care. It matters less on a single-storey garage roof you can reach from the garden with a hose. When we write the light plan for a flat roof rooflight, the glass specification is chosen alongside the position and orientation, so the coating is weighed against the trees, the fall and how often you can reach the roof. Where a unit is going into a room with trees overhead, we also look at where the skylight sits, since moving it a metre clear of a canopy can do more than any coating. The effect on the overall budget is covered on our costs page, and how we plan the light explains the survey that sets it all out. To see what it would mean for your roof, book a light survey.

Questions people also ask

Does self-cleaning glass work on a north-facing flat rooflight?

Yes. A flat rooflight faces the sky rather than a compass point, and diffuse daylight from a cloudy sky still carries enough ultraviolet to drive the reaction. It works more slowly in winter, when days are short, than in summer.

Can self-cleaning glass be added to an existing rooflight?

Not in a way that matches a factory coating. Spray-on treatments exist, but they are a different product. The practical route is to renew the glazed unit or replace the rooflight with one that has the coating built in.

Does the coating make the glass look tinted?

From below it is hard to see any difference. Seen from outside at a low angle, some coated glass has a faint blue or silvery reflection, which is usually less noticeable than solar control glass.

Will a self-cleaning skylight still need cleaning inside?

Yes. The coating is only on the outer face. The inner pane collects the same household dust and kitchen steam as any other glass, and is cleaned in the normal way.

Book a light survey

Tell us about the room

  • No obligation
  • Light plan in writing
  • 10-year guarantee
Book a survey Call