Why fixed is the normal answer
A walk-on rooflight is first a piece of floor, and floors are easiest to make strong, level and watertight when nothing moves. That is why the fixed unit is the default across the market.
The top pane of walk-on glass is a thick laminated build-up, carried on continuous bearing all the way round its edge. A fixed unit can sit on that bearing permanently, with the seals compressed once and left alone. The moment a pane has to lift or slide, the design has to solve several extra problems at the same time: the glass must be carried by a moving frame rather than a fixed bed, the frame must still give the pane full edge support when it closes, and the seal between moving and fixed parts must keep water out at a level where there is almost no upstand to help. The load ratings guide explains what the fixed bearing is doing and why it matters.
Weight is the other reason. Walk-on glass is heavy, as the answer on how heavy a walk-on rooflight is sets out, and a pane that has to be lifted by hand, a gas strut or an electric actuator needs a mechanism sized for that weight every time it moves.
The kinds of opening walk-on units you may find
Where a maker does offer an opening walk-on rooflight, it usually falls into one of a small number of patterns. The details vary from one product to the next, so read these as types to ask about, not as a specification.
- Hinged, for ventilation. The walk-on pane lifts on one edge, usually by an electric actuator, to let warm air out of the room below. It is closed and locked whenever anyone uses the terrace.
- Hinged, for access. A larger lifting unit that works as a hatch, so people can climb out from a stair or ladder onto a roof terrace, with the closed glass forming part of the terrace floor.
- Sliding. The pane runs horizontally over the adjoining roof or into a housing. Because it moves across the surface, the surrounding finish and the path it travels over need planning from the start.
Not every maker offers all three, sizes are often more limited than for fixed walk-on glass, and some opening units carry a different load rating from the same maker's fixed range. Those points are the reason to go to the product's own technical sheet before settling on a layout.
What changes when the glass opens
An opening walk-on rooflight is safe to walk on only when it is shut and locked. While it is open, it is a hole in the terrace floor, and it has to be treated that way.
That has practical effects on how the terrace is used. A pane that opens for air on a warm afternoon is open at exactly the time people want to sit outside. If the unit is on a roof terrace, the open edge is a fall risk to anyone on the terrace, and the Building Regulations guidance on protection from falling (Approved Document K) is relevant to how that edge is dealt with. The answer on whether a walk-on rooflight needs a guard rail covers guarding in more depth; for an opening unit, the question to put to the maker and to Building Control is what protection is needed while it is open.
Controls matter too. Some opening units can be linked to a rain sensor so they close when the weather turns, which is a common feature on opening flat rooflights. Whether that is offered on a particular walk-on product, and how the unit behaves if someone is standing near it when it closes, are points to confirm from the maker's details rather than assume.
Other ways to get air and access
If the aim is ventilation or a way out onto the roof, an opening walk-on unit is one answer, but it is rarely the only one. Splitting the jobs between two products often gives a better room and a simpler terrace.
A fixed walk-on pane can do what walk-on glass does best: bring daylight down into the room below while keeping the terrace or courtyard fully usable. Air can then come from somewhere that does not have to carry feet, such as an opening window in a wall, or an opening flat rooflight on a part of the roof nobody walks on. Warm air collects at ceiling level, so a high opening anywhere in the room helps it escape. For access onto a flat roof, a purpose-made access rooflight or a door from a stair enclosure is designed for that one job.
The comparison of walk-on and standard flat rooflights is useful here, because some roofs are better served by a standard opening skylight than by walk-on glass at all. On a roof terrace, the fixed and opening parts can often be placed so the glass you walk on never has to move.
How opening affects the light below
Choosing an opening walk-on skylight also changes the daylight in the room, and it is worth weighing that alongside the air and access.
An opening unit needs a deeper frame to hold the mechanism and the seals, so the glass area for a given opening can be a little smaller than with a fixed pane, and the frame edge may be more visible from below. Flat, horizontal walk-on glass already throws a hard-edged pool of sun into the room on a clear summer day, as the guide to glare below walk-on glass explains, and the frame of an opening unit sits inside that pool. In a Cambridge side return or basement room, where the walk-on glass is the main source of daylight, those few centimetres of frame are worth checking on the drawing before deciding.
At the light survey we look at where the sun will fall through the day and the year, how the room is used, and whether air is better brought in through the walk-on glass or somewhere else. The written light plan then sets out the position, size and glass for each part. You can read more about that approach on how we plan the light, or see the walk-on rooflight installation page for the wider picture.
Questions people also ask
Can I stand on an opening walk-on rooflight when it is closed?
Only if the maker rates it for that when closed and locked. Check the product's declared load rating, because an opening model may not carry the same rating as the maker's fixed range.
Can an opening walk-on rooflight be electric?
Some are, using actuators to lift the heavy pane, and some can be linked to rain sensors. What is available depends on the product, so confirm controls and sensors from the maker's details.
Does an opening walk-on rooflight need planning permission?
The same planning points apply as for fixed walk-on glass and the terrace it sits in. The answer on planning permission for walk-on rooflights covers them.
Are opening walk-on units made in large sizes?
Usually in smaller sizes than fixed walk-on glass, because of the weight to be moved. The answer on the largest size for a walk-on rooflight explains the limits for fixed panes.