Knowing what is on your roof now
Before any cast iron rooflight replacement is planned, it helps to be sure the unit really is an original and to understand why it is being changed. The answer shapes the consent route, the size of the new frame and how closely the replacement has to follow the old one.
A Victorian or Edwardian cast iron rooflight is easy to recognise once you know the signs. From outside it is a small, dark rectangle lying almost flat in the slope, usually taller than it is wide, with a hinged top edge and a lip of metal that the slates or tiles lap over at the sides and head. Inside, the frame is thin and cold to the touch, the glass is a single sheet (sometimes wired, sometimes replaced over the years with plain float glass), and a notched iron stay props the casement open. Many have a single vertical bar down the middle; smaller ones are one clear pane.
They survive in quantity on the rear slopes of Cambridge terraces in Romsey, Petersfield, Mill Road and De Freville, over attic stairs, box rooms and bathrooms, and on outbuildings, coach houses and barns in the villages. Some are the original castings. Others are later steel or iron copies from the twentieth century, which matters less for the replacement than for any listed building conversation, because the age of the fabric is part of what a conservation officer weighs.
The usual reasons owners decide to change one are practical: single glazing that runs with condensation every winter morning, a draught around the casement, a frame that no longer closes square, glass that has cracked, or a loft conversion that now needs a warm, insulated room under the slope. Whatever the reason, the goal on this page is the same: a new cast iron skylight replacement that reads like the original from the street and performs like a modern unit from inside.
Recording the old unit before it comes out
The single most useful thing you can do before a replacement is to measure and photograph the existing rooflight in detail. The record becomes the brief for the new unit, the evidence for any application, and the reference that proves the new one matches.
At our light survey we take a set of measurements and photographs that together describe the original fully. You can do much of it yourself first, from a loft ladder and a window across the street:
- the overall outside size of the frame, width and height, and the visible glass size inside it
- the position and width of any glazing bar, and whether there is one bar or none
- which edge is hinged and which way the casement opens
- the roof pitch, and how far the rooflight sits below the ridge and above the eaves
- the roof covering around it: Welsh slate, plain clay tile, pantile or something later
- how the frame meets the covering: lapped under, dressed with lead, or sealed with mortar
- photographs from the street, the garden and inside the room, with a tape in shot
The street photograph matters more than people expect. A conservation officer judges a replacement mainly by how it will look from public view, so a clear before picture taken from the pavement or the rear garden gives everyone a fixed point to compare against. The internal photograph records the opening itself: the depth of the reveal, the timber trimmers around it, and any old plaster or boarding that will be disturbed.
Record the orientation too. A compass reading on a phone is enough. It tells us which way the slope faces, which in turn decides the glass, and it is part of the light plan that comes with every written quote.

Matching size, proportion and the glazing bar
The new unit should follow the old one's outside size and proportion as closely as the manufacturer's range allows. Small differences are usually acceptable; a squarer or noticeably larger frame is the change that officers resist.
Conservation rooflights come in a set of standard sizes, and a good match to a Victorian original is often a stock unit. Where the original is an unusual size, some makers produce frames to order within limits. The aim is to keep the vertical, portrait shape, keep the frame close to the old outside dimensions, and keep the bar where it was. Our guide to conservation rooflight sizes and proportions goes through the standard range and how a size is judged on a historic slope.
It is tempting to go a size up while the roof is open, because a bigger pane means more light. On a listed building or a prominent slope in a conservation area, that choice is a planning change as much as a building one, and it should be discussed before it is ordered. On a rear slope outside any designation there is more freedom, but a much larger frame still loses the look that made the original worth copying.
If the original had a central bar, the replacement should have one in the same position. On a modern double glazed unit this can be an integral bar, where the glass is split into two sealed units either side of a structural bar, or an applied bar fixed to the outer face of a single sealed unit. The difference is visible close up and is something officers ask about; the glazing bars guide explains it.
| Feature of the original | What the replacement keeps | What changes |
|---|---|---|
| Portrait shape | Same proportion, close outside size | Slightly deeper frame section |
| Central bar | Bar in the same position | Integral or applied, on double glazing |
| Dark iron finish | Dark grey or black coated steel | Galvanised and powder coated |
| Top hinge, iron stay | Top hinged opening | Stay or electric opener, seals |
| Single glass | Clear outside look | Sealed double glazing, laminated inner pane |
Consent: listed buildings, conservation areas and Article 4
Replacing a cast iron rooflight can need listed building consent, planning permission or neither, depending on the building and where it stands. It is worth settling the route before anything is ordered, because steel conservation units are usually made to order.
On a listed building, the original rooflight is historic fabric, and removing or replacing historic fabric can need listed building consent even where the new unit looks almost the same. Listing covers the whole building, inside and out, not just the front elevation, so a rear rooflight on a listed cottage is included. Carrying out works that affect the character of a listed building without consent is a criminal offence, so the sensible course is to ask the council's conservation team before work starts. Our page on listed building consent for rooflights covers what the application includes, and a short heritage statement built from the record you made above is usually the core of it.
In a conservation area, a house (not a flat or maisonette) generally keeps permitted development rights for rooflights under Class C, provided the new unit does not project more than 150mm from the roof plane and does not rise above the highest part of the roof. A like-for-like conservation replacement normally sits well within that. Where an Article 4 direction has removed those rights, planning permission can be needed even for a close match; the guide to Article 4 directions and rooflights explains how to check.
In Cambridge and South Cambridgeshire, planning and conservation are handled by Greater Cambridge Shared Planning, and the city council's "check for constraints on development" map shows conservation areas and listed buildings. Around the wider area, East Cambridgeshire, Huntingdonshire and Uttlesford each run their own conservation teams, and Ely, St Ives and Saffron Walden all have large historic cores. We can help you gather the measurements and photographs an application needs, and we fit to whatever the consent says, but the decision rests with the council.
- The roof plane: the line of the tiles or slates. How far a window sits above it is what the eye picks up from the street.
- Standard roof window: frame and sash sit proud of the roof, the usual choice where appearance is not controlled.
- Standard flashing kit: a wide, visible collar around the frame.
- Conservation rooflight: set down so the glass sits flush with the slates, in a slim dark frame.
- Slim central glazing bar, echoing the cast-iron rooflights of Victorian roofs.
- Low-profile flashing tucked under the slates, so almost nothing shows around the frame.
What the new frame changes in the room below
A modern conservation unit keeps the outside look but changes almost everything you feel indoors: warmth, condensation, draughts and, depending on the glass, the heat and glare on a sunny afternoon.
Single glass in a cast iron frame is the coldest surface in the room by a long way. On a winter morning its inside face drops close to the outdoor temperature, warm moist air from the room condenses on it, and the water runs down the frame and into the timber below. Sealed double glazing in a thermally improved steel frame keeps the inner pane far warmer, so condensation is much less likely under normal ventilation. Replacement glazing also has to meet Part L of the Building Regulations, which currently sets a limiting U-value of 2.2 W/m²K for rooflights, and the units we fit are chosen to meet it. The thermal performance guide goes into frames and thermal breaks.
Light is the other change, and it is where orientation starts to matter. A small north-facing rooflight over an attic stair gives soft, steady light all day and needs nothing more than clear double glazing. The same size on a south slope puts a bright patch of sun on the floor or wall below for several hours around the middle of the day, and on flat Cambridgeshire land nothing shades it. Under a lowered ceiling in a loft room that can be warm in July. Solar control glass or a fitted blind handles it, and we set out which in the light plan. East and west slopes give low morning or evening sun that comes in at a steep angle and can land across a bed or a desk, so we look at where the furniture will stand before choosing the glass.
The glazing bar and frame take a little light compared with a standard roof window of the same outside size. On a small rooflight the difference is modest, and the inner pane is kept clear so the view of the sky is not blurred.
Opening, ventilation and access
The old iron stay can give way to a steel stay in the same style, a winding handle, or a concealed electric opener, depending on how high the rooflight sits and what the room is for.
Over a stairwell or a high loft ceiling, a rooflight you cannot reach is a rooflight that never opens. An electric actuator hidden in the frame, with a rain sensor that closes it when the first drops land, solves that without changing the outside look; see whether a conservation rooflight can be electric. In a bathroom, an opening unit also helps purge steam, which was part of the reason the old one ran with water.
If the replacement is part of a loft conversion, the room may need a means of escape, and a small Victorian-sized opening will not meet it. That is a question about size and position, and it is worth raising early, because an escape-size unit is a different frame from a like-for-like one and can alter the consent picture.
How the replacement goes on the day
Most single rooflight replacements take a day on site, sometimes a little longer where the opening needs new trimming timbers or the internal finish has to be made good afterwards.
The sequence is straightforward. Scaffold or a roof ladder goes up, depending on the height and position. Slates or tiles are carefully lifted around the old frame and set aside for relaying. The cast iron unit is released from the rafters and lifted out whole where possible. We check the trimmers and rafters around the opening, adjust the opening to the new frame if the size differs slightly, and fix the new conservation rooflight to the manufacturer's instructions. A dedicated flashing kit or leadwork is dressed around it, and the slates or tiles are relaid to meet the frame so it sits low in the covering. Inside, the reveal is lined, insulated and finished ready for decoration.
Where the roof covering around the old unit is fragile, and old Welsh slate can be, we tell you before the day rather than after. Matching slate or tile may be needed for any that break, and it is sensible to source reclaimed pieces in advance. The slate and tile guide covers how conservation units sit in each covering.
Where the work is notifiable under Building Regulations, we handle the Building Control notification, and the installation is covered by our 10-year workmanship guarantee. The rooflight itself carries its own manufacturer warranty.
What the old unit tells you about the new one
An original cast iron rooflight is a useful guide to where daylight works on that slope, because it was put there for a reason: to light a stair, a box room or a service space that had no other window.
Before simply swapping like for like, it is worth asking whether the room has changed. A box room that is now a study, or an attic that is now a bedroom, may need the light in a slightly different place, or a second rooflight lower down the slope. On a listed building or a front slope, the existing position is usually the one to keep, because it is the one officers expect. On an unlisted rear slope, there can be room to reconsider. That is part of what the light survey is for: we stand in the room, look at where the sun patch falls through the day, and write down the recommended position, size and glass, with the reasons.
What drives the cost of a replacement is mainly the unit (size, bar, opening type, glass), the access, the condition of the covering around it, and any consent work. The costs page sets out the factors in general terms, and the written quote after the survey gives the real figure for your roof. For the wider service, see conservation rooflight installation in Cambridge, or book a light survey through the quote form.
Questions people ask
Can I keep the original cast iron frame and just change the glass?
The better route is a complete new conservation rooflight in the same opening. A thin iron casement is not designed to carry a sealed double glazed unit, which is heavier and much thicker than the sheet glass it was made for.
Will the new rooflight look different from the street?
Very little, when the size, proportion, bar position and dark finish are matched and the frame is fitted low in the covering. The frame section is slightly deeper than the old casting, which is why the recorded street photograph is useful when comparing.
Do I need consent to replace a cast iron rooflight on a listed building?
It can be needed even for a close match, because the original is historic fabric. Ask the council's conservation team first and keep a written record of their answer.
Is a conservation rooflight warmer than the original?