Question

Is walk on glass safe if it cracks?

The short answer

A properly specified walk-on rooflight is designed so that a crack does not mean a fall. The walkable glass is a laminate of several plies, and if one breaks the others and the bonded interlayer should keep the pane in the opening. It is not safe to keep walking on, though. Stay off it, keep weight off it and arrange a replacement unit.

What a crack in walk-on glass actually means

Cracked walk-on glass is a pane that has lost part of its reserve strength, not one that is about to give way, provided it was built as a proper laminated walk-on unit.

The top of a walk-on skylight is not a single sheet. It is typically two or three sheets of toughened or heat-strengthened glass bonded together with a plastic interlayer, sitting above a sealed cavity and an inner laminated pane that faces the room. When people talk about walk-on glass being safe after a crack, they are relying on that stack. A break in one ply leaves the other plies spanning the opening, and the interlayer grips the broken fragments so they stay where they are instead of dropping.

Which ply has failed makes a real difference. Some build-ups use the uppermost ply as a sacrificial wearing layer, there to take knocks and grit, with the plies below doing the load-bearing work. A crack confined to that layer is unsightly and needs dealing with, but the structural plies beneath are still whole. A break that runs through the load-bearing plies is more serious, because the pane is then carrying its load with less glass than it was designed around. From the surface you usually cannot tell which is which, so the safe assumption is the worse one. How the layers are arranged in a typical unit is set out in how thick is walk on glass.

How laminated glass holds together after damage

Toughened glass on its own breaks into small, blunt pieces and keeps no strength at all; lamination is what turns that into a pane that stays in place.

When a toughened ply fails, the whole ply breaks up at once into a mesh of small fragments. Bonded to an interlayer, those fragments cannot fall. They stay stuck to the film, and the cracked ply still contributes a little stiffness by pressing its pieces against each other. Glass engineers call this post-breakage behaviour, and designers of overhead and floor glazing plan for it: the question they ask is not only whether the pane carries its rated load when whole, but whether it can still hold itself and a reduced load in place for long enough with a ply broken.

The interlayer matters here. Standard PVB is soft and allows a broken laminate to sag. Stiffer ionoplast interlayers keep a damaged pane flatter and firmer. Which interlayer a given product uses, and how its maker has rated it after breakage, varies between manufacturers and is something to read on that product's own data, not assume. The same applies to heat soak testing, which reduces, but does not remove, the small risk of a toughened ply breaking on its own because of a nickel sulphide inclusion in the glass.

What to do if you find a crack

Treat any crack as the end of that pane's working life: take the load off it, protect the room below and plan a replacement.

  1. Stop walking on it. Keep people, pets and children off the glass, and move any furniture, planters or barbecues that sit on or near it. A pane with a broken ply has less margin for a concentrated load such as a heel or a table leg.
  2. Mark it off. On a roof terrace or courtyard, set something across the glass or around it so nobody steps on it by habit, especially after dark.
  3. Look from below. Check the ceiling side for sagging, fragments or water. The inner pane is laminated too, so the room below should stay protected, but you want to know whether damp is getting into the cavity or the kerb.
  4. Photograph it. Pictures of the crack, where it starts and what was on the glass at the time help the manufacturer, your insurer and whoever replaces the unit.
  5. Arrange a replacement. Book a survey so the size, rating and fixing of the existing unit can be recorded and the new one ordered to suit.

If the crack sits in a garden or a basement lightwell, the same steps apply; the advice in walk-on glass over basements covers how those installations are laid out.

Why a cracked pane is replaced, not kept

A laminated walk-on pane cannot be restored to its rated strength once a ply has broken, so the only sound answer is a new unit.

The broken fragments are held by the interlayer, but the ply they came from no longer carries load, and nothing added to the surface brings that back. The sealed cavity may also have been compromised, which lets moisture in and mists the unit from inside over time. A cracked walk-on skylight is therefore replaced as a complete glazed unit, sized and rated to the opening. That is also the moment to check whether the original was specified to current loadings; units rated only to older concentrated-load figures are worth upgrading, as explained in walk-on rooflight load ratings.

A replacement is also a chance to change the glass. If the old pane threw a hard pool of sun into the room below, or felt slippery in the wet, the new one can carry a different finish or solar coating. The glare side of that is in glare and pools of sunlight below walk-on glass, and grip is in slip resistance of walk-on glass.

What usually causes walk-on glass to crack

Knowing the cause helps decide whether the new unit needs a different specification or the opening needs attention.

Common causes include a heavy or sharp object dropped on the glass, a concentrated load well above what domestic walk-on glass is designed for, such as a hot tub foot or a loaded planter, and an uneven or springy bearing that lets the pane flex more than intended. Thermal stress can play a part too: on a Cambridge terrace, flat glass sees the whole sky, and a pane half in hard sun and half under a parked chair or a stack of cushions heats unevenly. Occasionally a toughened ply breaks with no obvious trigger, which is the nickel sulphide risk mentioned above. What furniture a rated pane can take is covered in can you put furniture on a walk on rooflight.

Questions people also ask

Will cracked walk-on glass fall into the room below?

A correctly specified laminated unit is designed so that it should not. The broken fragments stay bonded to the interlayer and the inner pane is laminated as well. That depends on the glass being a genuine walk-on build-up on proper edge support, so keep off it until it is replaced.

Can I still use my roof terrace?

You can use the rest of the terrace if you keep clear of the damaged glass and mark it off. Move anything heavy that sits on the pane. For how terraces are planned around walk-on glass, see walk-on rooflights for roof terraces.

Is a scratch the same as a crack?

No. A scratch marks the surface and does not reduce the pane's strength in any meaningful way, while a crack means a ply has broken. Surface wear is covered in does walk on glass scratch.