Guide · Flat roof rooflights

Fixed vs Opening Flat Rooflights

An opening flat skylight lets warm, damp air out at the top of the room; a fixed one gives slimmer frames and fewer parts. The right choice depends on what the room below is used for and which way it faces.

12 min read9 chapters

What the choice actually decides

A fixed flat rooflight lets in light and nothing else; an opening one lets in light and lets out air. Deciding between them is really a question about the room underneath: what goes on in it, which way it faces and where its warm, damp air will end up.

Both types sit on the same kind of kerb, use the same families of glass and weather into the roof covering in the same way. From the garden, with the vent shut, you would struggle to tell them apart. The difference shows up inside, on a humid evening after the pasta has boiled, or at four o'clock on a July afternoon when the sun has been on a west-facing extension since lunchtime. In those moments an opening skylight gives the room somewhere to breathe at its highest point. A fixed one gives it a clear, unbroken view of the sky and a simpler unit with fewer parts.

So the useful question is not which type is better. It is whether this particular room needs an outlet in its ceiling. Some rooms plainly do, some plainly do not, and a few sit in between, where the answer depends on the other windows and doors, the orientation and how the space is used. The rest of this guide goes through those cases so you can see which camp your own room falls into before a survey. The wider picture of how a flat rooflight is specified, built in and finished is on our page about flat roof rooflight installation.

Why the ceiling is the place to let air out

Warm air rises and gathers under the ceiling, carrying heat, cooking steam and moisture with it. A vent at the top of the room lets that layer escape where it collects, which a window at head height cannot do nearly as well.

Anyone who has stood on a stepladder in a kitchen extension in August knows the effect. The air by the ceiling can be several degrees warmer than the air at the table. In a single-storey extension with a flat roof, that warm layer has nowhere to go: the garden doors and any side windows are lower down, so opening them lets cooler air in at the bottom but gives the hot air at the top only a slow, indirect route out.

Open a rooflight as well and the room starts to work like a chimney. Cooler air comes in low through the doors, warms, rises and leaves through the roof. This stack effect is simple physics, and it is the main reason an opening flat skylight clears a room so much faster than a window alone. It needs a low inlet to work properly, though. A rooflight opened in a room with every door and window shut will trade a little air but will not produce much of a draught.

The same logic explains why a fixed unit can feel stuffy in the wrong room. Glass above you warms the air immediately below it on a sunny day. If that air cannot leave, it sits there, and the top third of the room stays warm long after the sun has moved off the roof.

Room by room: where each type earns its place

The room's job is the best guide. Rooms that make steam or gather heat benefit from an opening unit; rooms used mainly for passing through, or lit from a north sky, are usually well served by a fixed one.

RoomUsual fitMain reason
Kitchen extensionOpeningCooking steam and heat at ceiling level
Bathroom or en-suiteOpeningMoisture and a room with small windows
South or west garden roomOpeningSummer heat under the glass
Side-return dining areaEitherDepends on doors and orientation
Hall, landing or stairwellFixedLight is the job; hard to reach
North-facing snug or studyFixedSoft light, little heat to shed
Garage or storeFixedSimple, secure, low use

Kitchens. The rear kitchen extension is the classic case for an opening skylight. An extractor hood deals with steam over the hob, but it does little for the heat of an oven, a dishwasher opening its door or a room full of people. On the long gault brick terraces around Mill Road and Romsey, where a kitchen extension may run four or five metres back from the house with the only doors at the far end, the roof is often the one place high enough to let that heat out. If the rooflight also sits over a worktop or island, as described in our guide to rooflights over kitchen islands, it does two jobs at once: task light by day and a vent directly above the place where the cooking happens.

Bathrooms and en-suites. A bathroom under a flat roof, whether in a dormer, a rear addition or a ground floor wet room, makes a lot of water vapour in a small space. An opening rooflight lets you clear the steam quickly after a shower and air the room through the day. It sits alongside a mechanical extract fan rather than replacing one, and the glass should be chosen for privacy as well as light if neighbours' windows look down on the roof.

Halls, landings and stairwells. Here the rooflight's job is light. The space is used for moments at a time, the ceiling is often high and awkward to reach, and there is rarely a heat or moisture load worth venting. A fixed unit is the natural choice, with the details covered in the answer on putting a rooflight above a staircase.

Garages, stores and utility spaces. A fixed unit keeps things simple and secure. A garage that is turning into a gym or workshop is the exception, because a room full of exercise or machinery gets warm quickly and benefits from a high vent.

Orientation, glass and summer heat

A flat rooflight faces the whole sky, but which way the room faces and what shades it still decides how much heat builds up. The more afternoon sun a room takes, the stronger the case for a vent it can open.

On the open land around Cambridge there are few hills and not many tall buildings outside the centre, so a flat roof on a rear extension usually sees the sun for most of the day. Near-horizontal glass catches the high summer sun almost square on, which is exactly when you least want the extra warmth. Two tools work together to keep that in check: the glass itself, and the ability to let the heat out.

Solar control glass reflects part of the sun's energy before it reaches the room, so less heat arrives in the first place. An opening vent removes the heat that does get through, along with everything else the room generates. On a south or west-facing extension, particularly one with a large area of glass in the doors as well, the two are usually specified together. On a north-facing room, or one shaded by the house for most of the afternoon, clear or lightly tinted glass on a fixed unit can be perfectly comfortable. Our guide to flat rooflight glazing choices goes through the options pane by pane, and the light planning page explains how we read a roof's orientation and sun path before choosing.

Blinds are the third part of the same picture. A blind cuts glare and some heat, but on a warm day it also traps a layer of hot air between itself and the glass. With an opening rooflight you can vent that pocket; with a fixed one it simply sits there. The answer on whether a flat rooflight can have an integral blind covers blinds built between the panes, which avoid the trapped layer altogether.

Building Regulations and ventilation

Approved Document F sets out how homes should be ventilated. An opening rooflight can help meet it, but it is one part of a room's ventilation rather than the whole of it, and the declared figures for the unit matter.

Part F distinguishes between background ventilation, extract ventilation and purge ventilation. Purge ventilation is the ability to clear the air in a room quickly, for example after burning toast or painting, and in houses it is normally provided by opening windows. An opening rooflight can form part of a room's purge ventilation, provided the manufacturer declares its free opening area and that area is enough for the room. Kitchens and bathrooms also need extract ventilation, which in practice means an extractor hood or fan, and an opening skylight does not take the place of that.

When a new rooflight goes into an existing flat roof, or is fitted as part of an extension, the work is normally notifiable under the Building Regulations. That brings in more than ventilation: Part L for the thermal performance of the unit, Part K for safety glazing overhead, Part B for fire near boundaries and party walls, and Part A for the structure around the opening. We handle the Building Control notification where the work is notifiable and fit to current Building Regulations, so the ventilation side is checked alongside everything else. If an extension is being designed by an architect, the ventilation strategy on the drawings will often already say whether the rooflight is meant to open; it is worth checking before the order goes in, because changing a fixed unit to an opening one afterwards means a new unit.

There is also a moisture point that has nothing to do with the vent itself. Whether a rooflight opens or not, the vapour control layer in the roof has to be carried up and sealed to the kerb, so damp air from a kitchen or bathroom cannot get into the roof build-up. The answer on whether a flat rooflight needs a vapour control layer explains that detail.

How opening flat rooflights open

A flat rooflight sits well above arm's reach, so opening units are nearly always electric. The mechanism, the controls and the rain sensor are the parts a fixed unit does without.

The common arrangement is a hinged vent: the glazed sash lifts on one edge, pushed by an electric chain or spindle actuator hidden in the frame. It opens far enough to let air out but not so far that rain blows straight in. Sliding units, where the whole glazed panel runs back along rails to leave a clear opening, are a different product aimed at roof terraces and access, and they need more space on the roof. Manual winding poles exist for low ceilings, but on a flat roof over a kitchen the vent is usually too high and too far across the worktop to reach comfortably.

Controls are a wall switch, a remote or a link to a smart home system. A rain sensor on the frame closes the vent within seconds of the first drops, which matters on a flat roof where a shower can arrive with little warning off the fens. Some systems add a wind sensor, a timer and a contact for a house alarm, so the rooflight closes itself when the house is set. All of this needs a power supply routed to the kerb, which is planned before the ceiling is finished. The full detail on sensors, wiring and control options is on our page about electric opening rooflight installation.

Two practical points are easy to overlook. An open vent is an open hole in the roof, so if insects or security worry you, ask about fly screens and restricted opening positions. And every moving part, from the hinges to the actuator, is something a fixed unit simply does not have, which is one reason fixed rooflights are the plainer, lower-maintenance choice where ventilation is not needed.

What a fixed rooflight gives you

Leaving out the opening mechanism buys slimmer sightlines, more glass for the same size of hole and a quieter, simpler unit. Where the room does not need a vent, those are real gains rather than a compromise.

An opening sash needs its own frame inside the outer frame, plus seals, hinges and an actuator. A fixed unit does away with all of that, so more of the opening is glass and less is frame. Looking up from inside, a fixed rooflight reads as a clean rectangle of sky, and in the frameless styles the glass appears to float on the kerb with almost no visible edge. If a minimal look is the priority, the guide to framed vs frameless flat rooflights explains how the two styles are built and weathered.

Fixed units are also the only option for some roof uses. Walk-on glass that you can stand on is always fixed, and very large single panes are generally made as fixed units because an opening sash of that size would be heavy and slow to move. With fewer parts, a fixed rooflight is also usually the less expensive of the two at the same size, and the factors that move the price either way are set out on our costs page.

The trade-off is the one described at the top of this guide. A fixed skylight cannot shed heat or steam, so in a room that makes either, it relies on windows, doors and fans to do that work. Where those are generous and well placed, that is fine. Where they are not, the room will tell you on the first warm day.

Mixing fixed and opening units in one room

A room with two or more rooflights rarely needs every one of them to open. One opening unit placed where the warm air gathers, with fixed units elsewhere, often gives the ventilation of a full set at the look and simplicity of a fixed run.

In a long extension, the warmest air tends to collect at the end furthest from the garden doors, above the kitchen. That is the sensible place for the opening vent: it is above the heat source and as far as possible from the inlet, so air is drawn across the whole room on its way out. Fixed units then take the rest of the roof, where they can be sized purely for light. Matching frames and glass across the set keeps them looking like one family from inside, even though one of them moves.

The same idea works in the narrow side returns common on Cambridge terraces, where a long strip of glazing runs beside the party wall. One section of the run can open while the rest stays fixed, provided the whole run keeps clear of the fire zone either side of the party wall. Our guides to planning multiple flat rooflights and skylights for side-return extensions deal with spacing and positioning in more depth.

At the survey we look at the room at the time of day you use it, note the doors, windows and extract already in place, and mark on the light plan which unit opens and why. That decision is written down alongside size, position and glass, so you know before the order is placed exactly what will move and what will not.

Questions people ask

A few questions come up whenever fixed and opening flat rooflights are compared side by side.

Can a fixed flat rooflight be changed to an opening one later?

Not by adapting the existing unit. A fixed rooflight has no sash or actuator to add, so converting it means replacing it with an opening unit, and running power to the kerb if it was not planned in. That is why it pays to settle the question before the first order.

Will an opening rooflight let rain in?

Not in normal use. The vent opens only part way, and a rain sensor closes it within seconds of the first drops. Heavy wind-driven rain with the vent left open and the sensor disabled is the case to avoid, which is why the sensor should stay switched on.

Is an opening rooflight enough ventilation for a bathroom on its own?

No. It is very good for clearing steam quickly and airing the room, but bathrooms and kitchens also need mechanical extract under the Building Regulations. The rooflight works alongside the fan, not instead of it.

Book a light survey

Tell us about the room

  • No obligation
  • Light plan in writing
  • 10-year guarantee
Book a survey Call