Question

Can you replace a single roof lantern glass panel?

The short answer

Yes, in most framed roof lanterns a single glass panel can be replaced on its own. Each pane is a separate sealed unit clamped between glazing bars under a top cap, so one misted or cracked unit can be measured, made and swapped without disturbing the rest. Matching the glass coating, and the age of the other panes, decide whether one panel or the whole lantern is the better move.

How a lantern holds each pane

A roof lantern is a kit of separate glass units sitting on a frame, which is why one pane can usually be changed without touching its neighbours.

Look up at a lantern from the kitchen and you see a ridge along the top, hip bars running down to the corners, and glazing bars dividing the long sides into bays. Each bay holds its own sealed double or triple glazed unit. The unit rests on gaskets along the bars and is clamped from outside by a pressure cap or top cap that screws or clips down over the joint. On most aluminium and uPVC lanterns the inside of each bar also carries a trim or cladding that hides the fixings.

To take out one pane, the installer releases the caps on the bars either side of it, lifts the old unit out, checks the seating and gaskets, sets the new unit in place and clamps it back down. The upstand, the roof covering and the plaster below stay as they are. The guide to replacing a failed roof lantern covers the other end of the decision, when the whole skylight is renewed.

Side panes and hip panes are not the same job

The long rectangular panes on the sides are the simpler swap; the shaped hip panes at each end need more care in measuring.

A rectangular lantern has two long side slopes made of rectangular units and two end slopes, each a single triangular or trapezoid unit. Those end units are cut to the angle of the hips and the pitch of the lantern, which varies from maker to maker. A new hip unit has to be made to that exact shape, with the coated face on the correct side, so we measure the old unit where it sits and take the angles from the frame, not just from a drawing.

PaneShapeWhat to check
Side bayRectangleWidth, drop, unit thickness
Hip endTriangle or trapezoidAngles, coated face, thickness
Square lantern endTriangleAll four may be identical

Sealed units are made to order, so there is a lead time between the survey and the fitting day. Where a pane is cracked rather than misted, the opening is made safe in the meantime. Our page on replacing a cracked rooflight explains that step.

Matching the glass so the light stays even

A new pane has to match the others in coating and tint, or the sun patch it throws on the floor will look different from its neighbours.

Lantern glass is rarely plain. It may carry a low-E coating, a solar control coating with a slight blue, grey or neutral cast, and a self-cleaning outer surface. Viewed from below on a bright Cambridge afternoon, a single pane with a different coating stands out: slightly warmer or cooler in colour, a touch brighter or darker, and it throws a differently coloured square of light onto the worktop. If the original glass specification is known from the paperwork or the spacer bar markings, we order to it. If not, we match by eye against the neighbouring panes on site and choose the closest current product.

Glass made today can also be clearer than a unit fitted fifteen years ago, so a perfect match is not always possible. On a side bay the difference is usually slight. On a hip pane, which you see head on from the kitchen table, it can be more obvious, and that is worth knowing before you choose.

When the whole lantern is the better upgrade

One pane is the right answer when the lantern is sound and the problem is isolated; several signs point to renewing the lantern instead.

Sealed units in the same lantern were usually made at the same time and have lived through the same summers. When one has misted from edge seal failure, the others are the same age. Our guide to why rooflights mist between the panes explains the mechanism. A full lantern replacement is usually the stronger choice when:

  • two or more panes have misted, or others show a faint haze at the edges;
  • the frame is uPVC that has yellowed, or aluminium without a thermal break that runs cold and gathers condensation;
  • caps, gaskets or seals for that lantern system are no longer made;
  • the lantern faces south or west and overheats, and better glass across every pane would change how the room feels in July;
  • the lantern sits over the wrong part of the room, and a new one on a revised upstand would light the table or worktop you actually use.

The wider trade-off is set out in glass only or full unit replacement, and the same question for flat rooflights and roof windows is answered in can you replace just the glass in a rooflight.

What the survey looks at

The survey confirms whether the frame will take a new pane cleanly, and whether it is worth doing so.

We check that the caps release without damage, that gaskets are available, that the bars are straight and the ridge is sound, and that the drainage channels are clear. We read the spacer bar on the failed unit for a date and maker where one is printed, and look closely at every other pane for early misting. We also look at the room below: the orientation of the lantern, where the sun lands through the day, and whether there is glare or overheating that a different glass would settle. The written light plan that comes with the quote then sets out the single pane option, the full lantern option where it is relevant, and the reasons for each, so you can decide with both in front of you. The misted and failed rooflight replacement page sets out how the work runs from there, and what affects the cost of replacing a misted rooflight covers the price drivers.

Questions people also ask

Can a single lantern pane be replaced from inside the room?

Usually not. On most lanterns the pressure caps that hold the glass are on the outside, so the pane is changed from the roof. On a single storey extension that can often be done from ladders and roof access, but it depends on the height and the roof finish. See does replacing a rooflight need scaffolding.

Will a new pane be covered by a warranty?

The new sealed unit carries its maker's glass warranty, and the fitting is covered by our 10-year workmanship guarantee. The original panes keep whatever cover they had, which on an older lantern may have run out. Our page on manufacturer warranties for misted rooflights explains what they usually include.

Does replacing one lantern pane need Building Control?

Replacing a sealed unit within an existing frame is generally not treated as notifiable work, although the new glass should still meet current thermal expectations. Renewing the whole lantern can be different, and the details are in Building Control for replacement rooflights.

Can I upgrade just one pane to triple glazing?

Only if the frame's glazing rebate is deep enough for the thicker unit, and many lanterns are not. A single triple glazed pane among double glazed ones also makes little difference to how warm the room feels, so that upgrade makes most sense across the whole lantern skylight.

Book a light survey

Tell us about the room

  • No obligation
  • Light plan in writing
  • 10-year guarantee
Book a survey Call