What the sealed cavity was doing for the room
A double or triple glazed rooflight keeps heat in because the gap between the panes is dry, still and, in most modern units, filled with argon. Misting tells you that gap is no longer sealed.
Heat leaves a warm room through glass in three ways: by conduction across the cavity, by convection currents inside it, and by radiation from the warm inner pane to the cold outer one. Each layer of a sealed unit tackles one of these. Argon is a heavier, slower gas than air, so it carries less heat across the gap. A low-E coating on one of the inner faces reflects radiant heat back into the room. The spacer bar and edge seal hold the whole thing shut and keep the cavity dry, with a desiccant inside the spacer soaking up the last traces of moisture.
When the edge seal gives way, outside air and water vapour work their way in. The desiccant fills up, and on cold mornings that vapour condenses on the inside faces of the glass. The mist you see from below is the visible sign of a seal that stopped working some time before. Our guide to why rooflights mist between the panes explains that sequence in detail. This page is about what it costs you in warmth.
How much extra heat a failed skylight lets out
Losing the argon alone raises the heat loss through the centre of the glass by something in the order of 10 to 20 per cent. That is real, but it is not the whole story.
Glazing performance is given as a U-value: the lower the number, the less heat escapes per square metre for each degree of difference between inside and out. The figures below are typical centre-of-glass values for vertical glazing, as a general guide. A rooflight laid flat or at a shallow pitch performs worse than the same glass stood upright, because warm air circulates more freely in a horizontal cavity, which is why Part L now assesses rooflights in the horizontal plane.
| Glass in the rooflight | Typical centre U-value (W/m²K) |
|---|---|
| Single glazed, including wired glass | about 5.7 |
| Older double glazing, air filled, no low-E | about 2.8 |
| Low-E double glazing, argon lost to a failed seal | about 1.4 to 1.6 |
| Low-E double glazing, argon intact | about 1.1 to 1.3 |
| Low-E triple glazing, argon filled | about 0.6 to 0.8 |
Two things can make a misted unit worse than that middle row. Some soft-coat low-E layers are sensitive to moisture, and years of condensation inside the cavity can dull the coating or break it down, pushing the unit back towards the performance of plain double glazing. And a unit that has been misted for a long time has usually been in the roof for a long time, which brings its own weaknesses.
Cold glass overhead is felt, not just measured
The comfort cost of a failed rooflight is often larger than the energy cost, because cold glass above your head changes how the whole room feels.
A room loses heat by radiation to any cold surface it can see. Stand under a rooflight whose inner pane is several degrees colder than it should be and you feel a chill on your head and shoulders, even when the thermostat reads 20°C. Warm air meeting that cold pane also cools, gets heavier and sinks, so a failed skylight over a kitchen island or a loft desk can set up a slow downdraught that feels very like a draught from a gap. The natural response is to turn the heating up, which is where the running cost really shows.
Cold inner glass also collects condensation on its room-side face in winter, as well as inside the cavity. In kitchens and bathrooms that water runs down to the frame and the lining. Whether that turns into a damp problem is covered in can a misted rooflight cause damp.
Why the age of the unit matters more than the mist
The mist is a symptom of age, and an older rooflight usually loses more heat through its frame and edges than through a failed cavity.
Plenty of rooflights on Cambridge extensions and loft rooms from the 1980s to the early 2000s have aluminium frames with little or no thermal break, metal spacer bars and no low-E coating at all. Around the edges of the glass the frame acts as a cold bridge, which is why condensation tends to form first along the bottom rail. On a flat roof the old upstand may be timber with little insulation behind the kerb, so the whole opening runs cold. Fitting a new sealed unit into an old frame restores the cavity but leaves those weak points in place. Our guide on glass only or full unit replacement sets out when a new sealed unit is enough and when the whole rooflight should go.
Sealed units do not last forever either. A good one is typically expected to last 20 to 30 years, and cheaper or poorly fitted units less. Our answer on how long rooflight glass lasts covers what shortens that life.
What a replacement rooflight gives back
A new rooflight restores the dry, gas-filled cavity and usually improves on the original, because current Building Regulations ask more of it.
Under Part L, a replacement rooflight in an existing home should meet a limiting U-value of 2.2 W/m²K for the whole unit, frame included, measured in the horizontal plane. Current double glazed rooflights with warm-edge spacers and thermally broken frames are generally designed to do better than that, and triple glazing goes further on a north slope or over a room that is heated all day. Where the replacement is notifiable we handle the Building Control notification; the guide to Building Control for replacement rooflights explains when that applies.
Replacement is also the moment to think about the light, not only the warmth. A south-facing skylight can take solar control glass so the room stays cooler in July; a north-facing one suits the clearest, most neutral glass to make the most of soft, steady light. Our light planning page shows how orientation shapes that choice, and whether a new rooflight will be brighter covers what changes in the room below. The full picture, from survey to fitting, is on our misted and failed rooflight replacement page. To have your own unit assessed, book a light survey or message us on WhatsApp.
Questions people also ask
Is a misted rooflight wasting a lot of money on heating?
On its own the glass loses somewhat more heat than it did, not several times more. The larger costs tend to come from an old frame, cold edges and the heating being turned up to offset the chill from cold glass. The real difference depends on the size, pitch and age of your unit, which a survey can check.
Will clearing the mist bring the insulation back?
No. Demisting can make the glass look clearer, but it vents the cavity and cannot put back the argon or the seal. The reasons are set out in can misted rooflight glass be cleared.
Does a misted skylight lose heat in summer too?
Heat flows both ways. In summer a failed unit passes more heat inwards from a hot outer pane, and older glass has no solar control coating to hold back direct sun. A replacement with the right glass for the slope helps in both seasons.
Should I replace a misted rooflight straight away?
Mist on its own is not a safety deadline, but the unit will not recover, and the extra heat loss and condensation return every winter. Planning the replacement for a dry spell, or alongside other roof work, is a sensible way to approach it.